• Title/Summary/Keyword: KS (Korea Standard)

Search Result 424, Processing Time 0.031 seconds

Evaluation Method of Plastic Pipe for High-Strength Water Supply (고강도 수도용 PVC관의 성능평가 연구)

  • Park, Jong-II;Lee, Chang Suck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • High-strength plastic water supply pipe evaluation method was evaluated in this study. Up to date, high strength water supply pipes that we install are mostly ductile cast iron pipes. Sometimes, a few PVC pipes are installed. Metal pipes have rust problem on the surface, causing serious damage to metal pipes and reducing the expected life span of water piping system. Nowadays, depending on technology development, some companies have improved properties of general PVC pipe performance with remarkable properties that exceed KS and ASTM standard. Here, we suggest a new method of performance evaluation for high-strength water plastic pipes.

A Study on the Standardization of the System Kitchen by Utilizing Reference Plane (조립기준면을 활용한 시스템키친의 표준화 연구)

  • Lee, Ga-Kyung;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.43-52
    • /
    • 2010
  • It has applied the design method of face to face dimension, an MC (Modular Coordination) design method, at design steps of an apartment house for standardization of architecture. But It has been still using center line size. A construction limit isn't specific on these center line size, and dead space occurs with excessive gaps as size matching isn't performed well between structural sieve and parts. And above all, measurement before construction isn't to expect standardization, and to increase custom-made furniture. We investigate manufacture of a preferential domestic system kitchen and construction state, and we derive from a problem in viewpoints of standardization for this. And we utilized a reference plane, and we present construction document and design plan in order to solve these problems. And we analyze an effect got by application of the assembly basis aspect that we presented, and we can raise efficiency of standardization of housing and construction industry, and we light ultimately up.

A Study on the Influence Factor in Measuring the Dynamic Stiffness and Loss Factor of Damping Materials (완충재의 동탄성 및 손실계수 측정 시 영향인자에 관한 연구)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.279-282
    • /
    • 2005
  • The aim of this study is to suggest the method of measuring the dynamic stiffness and loss factor of materials used under floating floors in the dwelling by korea standard (KS F 2868). According to the results, the amplitude change of an impact source have no effect on the variation of the dynamic stiffness and loss factor. Comparing with the heating before, heating makes lower the dynamic stiffness except the EPS. In EVA material, the loss factor is increased by heating.

  • PDF

A study on the development of global standardized size for souvenir T-shirts (관광문화상품 티셔츠의 치수체계 조사 및 치수표기법 제안)

  • Lee, Hyun-Hwa;Nam, Yun-Ja;Choi, Young-Lim
    • Fashion & Textile Research Journal
    • /
    • v.11 no.2
    • /
    • pp.293-300
    • /
    • 2009
  • Customers purchasing souvenir T-shirts in famous tourist sites in Korea are mainly foreigners. Nevertheless, these T-shirts are manufactures according to Koreans' body shapes or manufactures' own size system. Moreover, sizes are labelled only by domestic norms. The purpose of this study is to suggest global standardized size for T-shirts, which will provide more precise size information for customers. For this, sizing standards including KS, ASTM, JIS, and EN were surveyed and were compared. And souvenir T-shirts were collected in the tourist resort and the sizing systems and labels were analysed from them. Finally, we proposed a sizing system and labelling as an international standard for souvenir T-shirts.

A Study on the Outdoor Lighting Plan at Hoam Park in Chungju (충주 호암공원 야간경관 조명실태 및 개선방안에 관한 연구)

  • Chung, Yu Gun
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.51-56
    • /
    • 2006
  • As tourist and cultural city, Chungju city struggles to exploit the new tourism resources including lighting scenic spots. This study aims to analyze the present lighting situations and suggest the alternatives for improving outdoor lightings of Hoamji Park - one of the most famous landmark in Chungju city. For the purpose, field surveys and experiments were performed on selected settings. Illumination levels were measured to compare with the KS standard by using MINOLTA T-10 instruments and some findings were discussed. As a result, some alternatives to improve the park's night images including new lighting concept, lighting fixtures and installations were suggested.

Characterization of Humic and Fulvic Acids Extracted at the Soils of Korea and Its DB Establishment (국내 토양 휴믹물질의 특성 규명 및 DB 구축에 대한 연구)

  • 이창훈;유지호;신현상;정근호;이창우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.397-400
    • /
    • 2003
  • In this study, humic and fulvic acids in soils at the vicinity of domestic atomic power plants(NPPs), located in Yungkwang(YK), Uljin(UJ), Kori(KR), Koseong(KS), Wolseong(WS) area, and in volcanic ash soils of the Cheju island(Mt. Hanla(HL), Manjanggul(MJ)) were isolated, and characterized using chemical(elemental analysis, proton exchange capacity, molecular size distribution) and spectroscopic(UV/Vis., IR, FL, $^{13}$ C NMR spectra) methods. The results were compared with one another and compiled for their DB establishments. The humic substances distribution (humic acid, fulvic acid, Humin) in the soils were also determined by IHSS standard method. Main purpose of this study was to provide a basic data needed to evaluate the effect of humic substances on the migrational behaviour of radioactive elements in contaminated surface soil.

  • PDF

Technical Standard of high-Efficiency Inverter (고효율인버터 기술기준)

  • 박정우;이승윤;정수남
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.485-493
    • /
    • 2003
  • 2승 저감 형태의 부하특성을 갖는 공조용 팬이나 물을 순환시키는 펌프를 구동하는 전동기는 일반적으로 전원전압을 직입하여 사용한다. 따라서 전원 주파수인 60Hz가 회전속도의 기준이 되어 4극인 유도전동기를 예를 든다면 기준속도가 1800[rpm]이 되며, 이 속도는 부하 조건과 관계없이 운전되면서 경부하 조건에서는 불필요한 에너지를 많이 소모하는 원인이 되어왔다. 이런 문제점은 부하에 맞추어 속도를 제어해 줌으로써 소모전력을 현격히 줄일 수 있는데 이를 위해 일반적으로 인버터를 사용한다. 그런데 인버터에 대해서는 KS 기준이 없어 개인별 또는 기업체별로 가지고 있는 평가기준을 활용하여 인버터를 개발해 왔다. 이에 본 논문에서는 인버터 보급을 촉진시키기 위한 관련 정책을 분석하고 인버터에 대한 기술기준을 제시하여 인버터 평가기준을 보급하고자 한다.

  • PDF

Study of requirements for protective current transformers for transient performance (보호용 변류기의 과도성능에 대한 고찰)

  • Jung Heung-Soo;La Dae-Ryeol;Kim Sun-Koo;Roh Chang-il;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.839-841
    • /
    • 2004
  • IEC 60044-6 (Requirements for protective current transformers for transient performance) was established to Korea Standard (KS C IEC 60044-6 ; Instrument transformers Part 6 ; Requirements for protective current transformers for transient performance) in December 11, 2003. In this paper, requirements, test items and test methods protective current transformers for transient performance.

  • PDF

A Study on the Dynamic Properties by Loading Time of Floor Impact Noise Insulation Materials (바닥충격음 완충재의 재하시간에 따른 동적 특성 연구)

  • Kim, Heung-Sik;Jin, Pil-Hwa;Joo, Si-Woong;Jung, Sung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.942-945
    • /
    • 2005
  • The purpose of this study is to suggest a fundamental data for change of dynamic properties according to the loading time of resilient materials. 18 kinds of resilient materials included 4 representative types were measured at the load time of 24hours and 2hours by the method of Korea standard (KS F 2868) measuring the dynamic stiffness and the loss factor of materials under floating floors. As a result, the dynamic stiffness was increased rapidly in case of expandable polystyrene and rubber materials according to the load time, especially before 2 hours. The loss factor was represented that rubber materials with high elasticity are high, and expandable polystyrene, polyester, poly ethylene materials with low elasticity are low.

  • PDF

Analysis of Influence Factors on Dynamic Properties of Floor Impact Noise Insulation Materials (바닥충격음 완충재의 동적특성에 영향을 미치는 요인 분석)

  • Kim, Heung-Sik;Joo, Si-Woong;Kim, Dae-Jun;Kim, Byeung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.946-949
    • /
    • 2005
  • In this paper, influence factors on dynamic properties of floor impact noise insulation materials are suggested. For this purpose measurements on the dynamic stiffness and the loss factor of resilient materials are carried out by Korea standard (KS F 2868) according to the change of density, thickness, design pattern, and composition of materials. As a result the values of dynamic stiffness was decreased at high density and thick thickness, and that of loss factor was increased at low density. For dynamic properties, the pattern of lattice and waffle type material is better than that of plat type, and the mixed composition of materials is better than the composition of double layer materials at same thickness.

  • PDF