• Title/Summary/Keyword: KRISS

Search Result 590, Processing Time 0.025 seconds

Transmission Characteristics on Swelling Tolerances of Rectangular Waveguides for Q-Band (Q-Band용 도파관의 내부 돌기가 전송 특성에 미치는 영향)

  • Park, Kyung-Sik;Cho, Byung-Ho;Kim, Ki-Chai;Kang, Jin-Seob;Kim, Jeong-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.108-113
    • /
    • 2014
  • This paper presents the influence on the transmission characteristics of swelling in rectangular waveguides for Q-band. We derived the Green's functions of the waveguide with eigenfunction expansion method. The reflection coefficient of the waveguide with a swelling is calculated by using internal impedance in order to investigate the influence of swelling in the waveguide. In order to check the validity of the theoretical analysis, the calculated reflection coefficients are compared with the measured results.

Influence of Adaptor on the Calibration of Inductance Standards

  • Kassim, Dewi Mohd;Kim, Dan Bee;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.911-917
    • /
    • 2018
  • Influence of the adaptors on the calibration of $100{\mu}H$ inductance standard was studied as a function of torque, applied when tightening the standard inductor terminal with the adaptor. Two different homemade adaptors of BPO gold-plated brass (BPO-Au) and banana-copper (BN-Cu) were made for the connection between the LCR meter and the inductance standard. The measured inductance (L) of the standard inductor and the contact resistance ($R_C$) between the adaptor and the standard inductor terminal showed exponential decreases against the torque increase from $25cN{\cdot}m$ to $150cN{\cdot}m$. The measured L and the calculated equivalence series resistance ($R_S$) were dependent on the adaptor type as well as on the $R_C$. The results of the adaptor analysis imply that the BPO-Au adaptor with the lower $R_C$ is more suitable for the inductance calibration. The calculated inductance of $99.956{\mu}H$ corrected by subtraction of the adaptor inductance and the contact resistance contributions from the measured value using the BPO-Au adaptor agreed well with the certificate ($99.948{\mu}H$) of the PTB within the measurement uncertainty of $140{\mu}H/H$.

Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy (경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

MEIS를 이용한 Cu3Au(100)의 Surface Induced disorder 직접관찰

  • 오두환;강희재;채근화;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.179-179
    • /
    • 1999
  • Cu3AU(100) 단결정은 fcc 구조를 가지고 있으며 (100)면은 Cu와 Au가 1:1로 존재하고 가운데(200)면은 Cu만 존재한다. 따라서 Au 층은 (100)면에서만 존재하여 각 Au층은 서로 0.5nm 떨어져 있다. 이와 같은 Cu3Au(100) 단결정을 MEIS(Medium Energy Ion Scattering Spectroscopy) 실험 장비를 사용하여 0.35nm 떨어져 있는 Single unit cell의 윗면과 아래면, 즉 첫 층의 Au와 셋째층의 Au의 층분리를 통해서, 온도 변화에 따른 Cu3Au(100) 단결정의 표면 물리적 현상인 surface induced disorder을 밝혀내고자 한다. 우선 두 Au층의 분리 시도는 수소이온을 이용한 실험 조건에서는 extremely glancing exit angle 등 극한의 산란조거에서도 성공하지 못하였다. 깊이 분해능을 정해주는 electronic energy loss를 극대화하기 위해 수소이온이 아닌 질소 이온을 사용하여 energy spectra를 측정해 본 결과 아래 그림에서와 같이 표면 Au 층과 표면 셋째 Au층을 구분할 수 있었다. <110>으로 align된 조건에서는 셋째층의 Au 원자들이 완전히 shadow cone 내부에 존재하여 관측되지 않지만 9.75$^{\circ}$ tilt 한 경우 셋째층의 Au 원자들이 shadow cone 바깥으로 나오게 되어 그림에서와 같이 첫째 층과 셋째 층이 확실히 분리되어 측정되었다. 이를 바탕을 Cu3Au(100)의 온도변화에 다른 order disorder and segregation 현상을 측정하였다. ordered Cu3Au(100)은 28$0^{\circ}C$ 근처에서 surface층이 먼저 disordered상으로 바뀌는 surface induced disorder 현상이 일어나고 bulk transition 온도 39$0^{\circ}C$ 이하에서 R.T으로 온도를 낮추면 본래의 ordered 구조로 되돌아간다. 하지만 bulk transition 온도를 지나면 order-disorder transition이 비가역적이고 segregation 현상이 일어난다.

  • PDF

Transmission Characteristics on Dimensional Tolerances of Millimeter-Wave Rectangular Waveguides (밀리미터파용 구형 도파관의 단면 치수 변화에 의한 전송 특성)

  • Park, Kyung-Sik;Kim, Ki-Chai;Kang, Jin-Seob;Kim, Jeong-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.722-729
    • /
    • 2013
  • This paper presents the influence on the transmission characteristics of dimensional tolerances of rectangular waveguides usually used as a low-loss transmission line in the millimeter-wave band. We derived the Green's functions of the waveguide with eigenfunction expansion method. The reflection coefficient of the waveguide with a post is calculated by using internal impedance in order to investigate the influence of dimensional tolerances of the waveguide. In order to check the validity of the theoretical analysis, the calculated reflection coefficients are compared with the measured results.

Fabrication of a Novel High Temperature Platinum Resistance Thermometer (새로운 고온백금저항온도계의 설계 및 제작)

  • Gam, K.S.;Park, J.C.;Chang, C.G.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.24-32
    • /
    • 2001
  • High temperature platinum resistance thermometers(HTPRTs) were designed and fabricated using a synthetic sapphire single crystal as sensor former, insulation and protection tube, and its characteristics was investigated. Several fixed points measurement showed that the sapphire HTPRTs were satisfied with the ITS-90 criteria as the interpolating thermometer. The temperature-resistance characteristics of HTPRT was fitted to the quadratic relationship in the temperature range from $500^{\circ}C$ to $1500^{\circ}C$. The reproducibility of Cu freezing point realized using the sapphire HTPRT was ${\pm}19.2\;mK$. The insulation resistance of the HTPRT exponentially decreased as temperature increased, and showed to $63\;k{\Omega}({\sim}31.5\;mK)$ at $1500^{\circ}C$.

  • PDF

중 에너지 이온 산란 분광법을 이용한 $Cu_3Au$(100) 단결정의 표면 조성 변화 측정

  • 오두환;강희재;채근화;황정남;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.143-143
    • /
    • 2000
  • MEIS를 이용하여 Cu3Au(100)에서 단원자층 분해능을 얻기 위한 연구를 하였다. 우선 수소이온을 이용한 첫째층과 셋째 Au층의 분리 시도는 extremely glancing exit angle 등 극한의 산란조건에서도 성공하지 못하였다. 깊이 분해능을 정해주는 electronic 에너지 손실을 극대화기 위해 수소이온 대신 질소 이온을 사용하여 에너지 스펙트럼을 측정해 본 결과, 표면 Au 층과 표면 셋째 Au 층을 구분할 수 있었다, <110>으로 정렬된 조건에서는 셋째 층의 Au 원자들이 완전히 shadow cone 내부에 존재하여 관측되지 않지만 9.75$^{\circ}$tilt한 경우 셋째 층의 Au 원자들이 shadow cone 바깥으로 나오게 되어 첫째 층과 셋째 층이 확실히 분리되어 측정되었다. 이 연구에서 MEIS로 단원자층의 분해능을 얻는데 성공하였다. 이러한 단원자층 분해능으로 시료의 온도변화에 따른 표면 첫째 층의 Au 의 조성변화를 관찰하였고 이를 전산 모사 하였다. 이 결과 벌크 전이 온도인 39$0^{\circ}C$이하에서 표면 첫째 층 Au의 조성이 감소하는 것을 관찰하였고 이러한 감소는 45$0^{\circ}C$근처까지 계속되었으며, 다시 온도를 실온으로 낮추면 본래의 질서화된 상태로 되돌아감을 확인하였다. 그리고 이를 전산 모사 한 결과, 표면 첫째 층의 Au가 표면 둘째 층으로 이동해 감을 알 수 있었다.

  • PDF

Sequential Formation of Multiple Gap States by Interfacial Reaction between Alq3 and Alkaline-earth Metal

  • Kim, Tae Gun;Kim, Jeong Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.129.2-129.2
    • /
    • 2013
  • Electron injection enhancement at OLED (organic light-emitting diodes) cathode side has mostly been achieved by insertion of a low work function layer between metal electrode and emissive layer. We investigated the interfacial chemical reactions and electronic structures of alkaline-earth metal (Ca, Ba)/Alq3 [tris(8-hydroxyquinolinato)aluminium] and Ca/BaF2/Alq3 using in-situ X-ray & ultraviolet photoelectron spectroscopy. The alkaline-earth metal deposited on Alq3 generates two energetically separated gap states in sequential manner. This phenomenon is explained by step-by-step charge transfer from alkali-earth metal to the lowest unoccupied molecular orbital (LUMO) states of Alq3, forming new occupied states below Fermi level. The BaF2 interlayer initially prevents from direct contact between Alq3 and reactive Ca metal, but it is dissociated into Ba and CaF2. However, as the Ca thickness increases, the Ca penetrates the interlayer to directly participate in the reaction with underlying Alq3. The influence of the multiple gap state formation by the interfacial chemical reaction on the OLED performance will be discussed.

  • PDF

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

Comparison of AT1- and Kalman Filter-Based Ensemble Time Scale Algorithms

  • Lee, Ho Seong;Kwon, Taeg Yong;Lee, Young Kyu;Yang, Sung-hoon;Yu, Dai-Hyuk;Park, Sang Eon;Heo, Myoung-Sun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.3
    • /
    • pp.197-206
    • /
    • 2021
  • We compared two typical ensemble time scale algorithms; AT1 and Kalman filter. Four commercial atomic clocks composed of two hydrogen masers and two cesium atomic clocks provided measurement data to the algorithms. The allocation of relative weights to the clocks is important to generate a stable ensemble time. A 30 day-average-weight model, which was obtained from the average Allan variance of each clock, was applied to the AT1 algorithm. For the reduced Kalman filter (Kred) algorithm, we gave the same weights to the two hydrogen masers. We also compared the frequency stabilities of the outcome from the algorithms when the frequency offsets and/or the frequency drift offsets estimated by the algorithms were corrected or not corrected by the KRISS-made primary frequency standard, KRISS-F1. We found that the Kred algorithm is more effective to generate a stable ensemble time scale in the long-term, and the algorithm also generates much enhanced short-term stability when the frequency offset is used for the calculation of the Allan deviation instead of the phase offset.