• 제목/요약/키워드: KRISS

검색결과 589건 처리시간 0.038초

KRISS 에서 수행된 음향관련 교정 및 시험 검사 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1767-1771
    • /
    • 2000
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 1999. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

휴대용 표면저항 측정기 개발 (A Development of Hand Held Type Surface Resistance Meter)

  • 강전홍;유광민;김한준;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2050-2051
    • /
    • 2008
  • 디스플레이 산업이 급속도로 발전함에 따라 touch screen 및 panel에 사용되고 있는 ITO(Indium Tin Oxide)박막의 표면저항에 대한 정밀 측정이 요구되고 있으며, 표면저항 측정은 주로 FPP(Four-Point Probe) 원리를 이용한 측정기를 사용하고 있다. 대부분의 면저항 측정기는 single 방식을 적용하고 있으나 이 방식은 가장자리 효과가 크며, 시료의 크기 및 두께와 핀 간격에 대한 보정계수를 적용하여야 하는 단점이 있다. 본 연구는 가장자리 효과가 거의 없고, 보정계수를 적용할 필요가 없는 dual 방식을 적용한 표면저항 측정기를 개발하였다. 개발된 표면저항 측정기는 휴대용으로 누구나 쉽고 정확하게 사용할 수 있으며, 측정 정확도는 지시값의 1.0 % 이하이고, 측정범위는 $4m{\Omega}/sq{\sim}20k{\Omega}/sq$ 이다.

  • PDF

대면적 전도성 박막의 면저항 정밀측정 (Principle Measurement for Sheet Resistance of Large Size Conductive Thin Films)

  • 강전홍;유광민;이상화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1515-1516
    • /
    • 2015
  • Touch panel 및 Touch screen 등의 투명전극으로 많이 사용되고 있는 ITO(Indium Tin Oxide)나 CNT(Carbon Nano Tube) 등 전도성 박막의 면저항을 쉽고 빠르게 측정하기 위하여 van der Pauw method를 이용한 면저항 측정기를 개발하였다. 이 면저항 측정기는 대면적 시료의 면저항을 측정 할 수 있어 매우 편리하다. 면저항 측정은 주로 Four Point Probe method로 측정하는 것이 일반적이나 본 연구에서는 van der Pauw method를 이용한 측정값과 Four Point Probe method로 측정한 결과를 비교한 결과 1 % 이내에서 일치하였다. 개발된 측정기의 측정 정확도는 지시값의 1.0 % 이하이고, 측정범위는 $2{\Omega}/{\square}{\sim} 5k{\Omega}/{\square}$이다.

  • PDF

4탐침 측정기술이 비저항 측정 정밀 정확도에 미치는 영향 (The Effects of the Four Point Probe Measurement Technique on the Precision and Accuracy in Electrical Resistivity Measurements.)

  • 강전홍;유광민;김한준;한상옥;김종석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.267-269
    • /
    • 2003
  • 반도체 웨이퍼 및 각종 박막의 면/비저항(sheet/resistivity resistance)의 측정에 비교적 간단히 측정할 수 있고 측정정확도가 높은 4탐침(four-point probe)방법이 널리 사용되고 있다 또한 4탐침 측정방법은 높은 분해능의 contour map작성과 ion implantation의 doping accuracy 및 doping uniformity의 측정에도 사용된다. 최근 재료의 소형, 박막화 경향으로 볼 때 정확한 비저항 측정의 필요성이 요구되고 있으며 이에 따라 4탐침 측정기술인 single 및 dual configuration method로 실리콘 웨이퍼에 대한 비저항의 측정 정확도를 고찰한 결과 dual configuration 측정방법이 single configuration측정 방법에 비하여 정밀 정확도가 더 좋은 것으로 고찰되었다.

  • PDF

방사선이 조사된 PE와 PP의 전기적 특성에 미치는 습도효과 (Humidity Effects on Electric Property in ${\gamma}$-Ray Irradiated PE and PP)

  • 강전홍;김한준;유광민;한상옥;김종석;박강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1458-1459
    • /
    • 2002
  • PE(Polyethylene)와 PP(Polypropylene)의 sheet 에 $Co^{60}{\gamma}$-ray 선원을 실온, 대기 중에서 10 kGy, 30 kGy, 50 kGy의 방사선량으로 조사시키고 습도 분포에 따른 표면 및 체적 저항을 측정한 결과 방사선이 조사되지 않은 시료와 방사선이 조사된 시료와의 저항 값은 큰 차이를 보이지 않았으나 습도 효과에 따른 변화는 습도 분포가 높을수록 저항 값은 상대적으로 낮게 나타났다.

  • PDF

가속도계 정밀 위상 교정 시스템 (Precision Phase Calibration System of Accelerometers)

  • 이용봉;정성수;진종한
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

Chemosensory-Event-Related Potentials to Olfactory Stimulations

  • Min, Byung-Chan;Park, Se-Jin;Kim, Chul-Jung;Masashi Wada
    • 감성과학
    • /
    • 제1권2호
    • /
    • pp.113-119
    • /
    • 1998
  • A new device introducing brief pulses of odorozed air synchronized with subject's respiration to human subjects creating a positive response was developed. By the using superimposition technique of an evoked potential the positive responses to skatole in normal subject's were distinguishable. The odorant pulse trigger was the subject's respiration. Responses to aerosolized skatole consisted mainly of a positive wave with a peak latency of approximately 150 ms. In our cases, saturation of responses was found after 4-5 averagings with the responses becoming most clear after 7-8 averagings. And in cases of Alzheimer disease very quick adaptation was recognized.

  • PDF

Field-Curvature Correction According to the Curvature of a CMOS Image-Sensor Using Air-Gap Optimization

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.658-664
    • /
    • 2015
  • Lens designers generally refer to flat image fields and attempt to minimize the field curvature. Present-day CMOS image sensors for mobile phone cameras, however, are not flat, but curved. Sometimes it is necessary to generate an intentional field curvature according to the degree and direction of the CMOS image-sensor’s curvature. This paper presents the degree of curvature of a CMOS image sensor measured using an interferometer, and proposes an effective compensation method that minimizes the net field curvature through optimizing the air gap between lens elements, which is demonstrated using simulations and experiments.

국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구 (A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow))

  • 임기원
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF