• Title/Summary/Keyword: KF94

Search Result 38, Processing Time 0.02 seconds

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.113-120
    • /
    • 2023
  • The purpose of this study was the accuracy of cardiac compression, fatigue, and physiological changes of the rescuer for different mask type in cardiopulmonary resuscitation(CPR). Data collection was from 9 to 12 May 2022, the participants were a total of 24 paramedic students with a BLS provider at D University. The students participated in an experiment in which 12 students each wore a surgical mask (Dental mask) and a fine particle 94% blocking mask (KF94 mask) and performed CPR for 2 minutes over a total of 7 times. As a result of the study, in the analysis of the quality of the rescuer's chest compression according to the type of mask, there was a significant difference in the compression speed (F=24.91, p<.001) and bad compression hand position (F=14.54, p=.024) in the group wearing the KF94, Fatigue showed significant differences in both the Dental mask group (F=51.16, p<.001) and the KF94 mask group (F=63.49, p<.001). Among the physiological changes, heart rate showed a significant difference between the Dental mask group (F=34.79, p<.001) and the KF94 mask group (F=35.55, p<.001), and the respiratory rate showed a significant difference between the Dental mask group (F=25.02, p=.001) and the KF94 mask group(F=23.02, p=.002). Therefore, in order to improve the quality of efficient chest compression and reduce the fatigue and physiological changes of rescuers, it will be necessary for rescuers to wear suitable personal protective equipment.

Effects of Wearing COVID-19 Protective Face Masks on Respiratory, Cardiovascular Responses and Wear Comfort During Rest and Exercise (휴식과 운동 중 COVID-19 대응 보건용 마스크 착용이 호흡·심혈관계 반응 및 착용감에 미치는 영향)

  • Jung, Jae-Yeon;Kang, ChanHyeok;Seong, Yuchan;Jang, Se-Hyeok;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.862-872
    • /
    • 2020
  • This study explores the effects of facemasks on respiratory, thermoregulatory, cardiovascular responses during exercise on a treadmill and at rest. Five male subjects (25.8 ± 0.8 y, 171.8 ± 9.2 cm in height, 79.8 ± 28.1 kg in weight) participated in the following five experimental conditions: no mask, KF80, KF94, KF99, and N95. Inhalation resistance was ranked as KF80 < KF94 < N95 < KF99 and dead space inside a mask was ranked as KF80 = KF94 < N95 < KF99. The surface area covered by a mask was on average 1.1% of the total body surface area. The results showed no significant differences in body core temperature, oxygen consumption (VO2), carbon dioxide production (VCO2), heart rate or subjective perception among the five experimental conditions; however, cheek temperature, respiratory ventilation and blood pressure were greater for KF80 or KF94 conditions when compared to KF99 or N95 conditions (p<0.05). The differences among mask conditions are attributed to the dead space or specific designs (cup type vs pleats type) rather than the filtration level. In addition, the results suggest that improving mask design can help mitigate respiratory resistance from increased filtration.

Effects of Heating and UV Sterilization of Repeatedly Reused Face Masks on Inhalation Resistance and Fiber Structure (보건용 마스크 재사용을 위한 가열과 자외선 살균이 마스크의 안면부 흡기저항 및 섬유구조에 미치는 영향)

  • Jung, Jae-Yeon;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.23 no.3
    • /
    • pp.406-414
    • /
    • 2021
  • This study aimed to evaluate the inhalation resistance(IR) and fiber structure of disposable masks when exposed to repeated heating and ultraviolet(UV) sterilization. The experiments consisted of a lab-scale and a field test. For the lab-scale test, KF94 and N95 masks were selected and a trial was composed of three repetitions of an 80-min sterilization. For the field test, a subject participated over four days, of which a KF94 was worn without sterilization, and the same trial was conducted during the next four days with daily sterilization. The results showed that the IR of the KF94 mask(9.5 Pa) gradually increased according to the sterilization up to the second repetition(15.6 Pa) but decreased at the third treatment(9.7 Pa). However, the N95 mask did not showany tendency of IR during the repetitions. Microscope photos showed several warped or blackened fibers in the stiffener layer after the repeated sterilization. After wearing a KF94 mask for four consecutive days, its IR decreased until the three days but increased the fourth day, whereas another KF94 mask with sterilization showed an increase in IR for the four days. In the microscope-photos after the consecutive four days, outside fibers and stiffener layers were warped or became less dense. In summary, the IR of the KF94 mask slightly increased through the three~four rounds of heating and UV sterilizations, but the fiber structures were not significantly deformed by the repeated sterilization. To reduce discarded mask waste, the repeated sterilization of masks can be recommended.

Usage of Filtering-facepiece Masks for Healthcare Workers and Importance of Fit Testing (보건의료종사자의 안면부여과식 마스크의 사용과 밀착도검사의 중요성)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • Objectives: One aim of the study is to compare filtering facepiece masks for healthcare workers between Korea and other countries. The other is to emphasize the importance of fit testing for these masks using an analysis of previous research. Materials: An extensive literature review was performed by searching a number of websites and existing studies. Results: KF94 and KF99 masks certified by the Korean CDC are suitable for healthcare workers as filtering facepiece masks. The standards for these respirators are similar to FFP2 and FFP3 of EN 143 and 149. The performance, such as filtering efficiency, is almost the same between KP94 and N95. It was found that fit testing of respirators for healthcare workers was important to reduce infection risk. Conclusions: KF94 should be emphasized as filtering facepiece masks for healthcare workers rather than N95. Even though Korea has no fit testing regulations, implementing fit testing in healthcare settings is strongly recommended to decrease infection risk.

Filtration Efficiencies of Commercial Face Masks in Korea for Biological Aerosols (국내 출시 마스크의 바이오에어로졸 여과효율 평가)

  • Choi, Sueun;Choi, Doseon;Jang, Sung Jae;Park, SungJun;Yoon, Chungsik;Lee, Kiyoung;Ko, GwangPyo;Lee, Cheonghoon
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.116-122
    • /
    • 2022
  • Background: The recent COVID-19 pandemic is one of the worst disease outbreaks of the 21th century. Due to a lack of reliable antiviral therapeutics, wearing face masks is recommended to prevent airborne infection originating from virus-contaminated bioaerosols. Objectives: The aim of this study was to evaluate the filtration efficiencies of face masks that are commercially available in South Korea for a biological aerosol of Staphylococcus aureus (S. aureus) and murine coronavirus, a well-known surrogate for human coronaviruses. Methods: We collected six different kinds of commercial masks: two Korea Filter (KF)94 (KF94-1, KF94-2) masks, one surgical (Surgical-1) mask, one anti-droplet (KF-AD-1) mask, and two dust (Dust-1, Dust-2) face masks. S. aureus (ATCC 6538), a well-performing test bacteria and murine coronavirus (ATCC VR-764) were prepared under a suitable culture condition. Then, a mask biological filtration tester was used to examine the microbial filtration efficiencies of masks. Test microorganisms were quantitatively measured via cultivation methods and microbial filtration efficiencies were calculated appropriately. Results: All face masks showed over 99.6% filtration efficiency for S. aureus or murine coronavirus. There were no significant differences among the bacterial filtration efficiencies of the face masks. KF94-1 (99.97±0.08%) and Dust-1 mask (99.97±0.07%) showed the highest (over 99.9%) filtration efficiency for murine coronavirus. KF94-1 or Dust-1 masks showed a significant virus filtration efficiency compared to Surgical-1 mask (p<0.05; Mann-Whitney U test). Conclusions: All the commercially available face masks used in this study can filter S. aureus or murine coronavirus in bioaerosols efficiently, regardless of the mask type. Therefore, our results suggest that wearing a certified face mask is a reliable means to prevent the transmission of infectious airborne diseases via biological aerosols.

Bacterial Filtration Efficiencies of KF94 Masks According to Wearing Duration (착용 기간에 따른 KF94 마스크 세균여과효율 변화 연구)

  • Jongmin Park;Yeram Yang;SungJun Park;Kiyoung Lee;Cheonghoon Lee;Chungsik Yoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.48-56
    • /
    • 2024
  • Objectives: The coronavirus pandemic that began in 2019(COVID-19) has been one of the worst pandemics of the 21st century. Masks have been used to prevent COVID-19, but there are currently no standards for the long-term use of masks in the Republic of Korea. This study was conducted to assess the microbiological safety of KF94(Korea Filter 94) disposable face masks according to wearing duration by evaluating the bacterial filtration efficiencies of masks worn by research participants. Methods: A commercially available KF94 mask certified by the Ministry of Food and Drug Safety(MFDS) in the Republic of Korea was selected as the test mask. The research participants(n = 15) wore masks for the durations of one, three, and seven days. Participants also reported several parameters, including wearing time, makeup frequency, and storage. Bacterial filtration efficiencies of the worn masks were measured by a mask bioaerosol filtration tester. Staphylococcus aureus(S. aureus) was used as the test bacteria and quantitatively measured through the cultivation method. Then, bacterial filtration efficiency was calculated using the formula suggested by the MFDS. Results: All worn masks showed over 99.98% of mean bacterial filtration efficiency for S. aureus. There were no significant differences among bacterial filtration efficiencies of face masks according to wearing duration. There was also no significant difference among bacterial filtration efficiencies among participants. There was no correlation between the results of bacterial filtration efficiencies and reported parameters from participants. Conclusions: In the absence of significant external damage to the mask, the bacterial filtration efficiency of the mask can be maintained even after seven days of wearing. This result suggests that KF94 masks certified by the MFDS can be used repeatedly for about a week without loss of bacterial filtration efficiency.

Radon Blocking Effect of Mask used in Everyday Life (일상생활에서 사용하는 마스크의 라돈 차단 효과)

  • Cheon, Se-Hyeon;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.313-318
    • /
    • 2020
  • Since radon is an inert gas and is a monoatomic molecule, the size of one particle represents the size of an atom, which means that it has a radius of approximately 1 to 100 nm. Therefore, if the mask has a radius smaller than the size of general fine dust and ultra fine dust, but it is possible to block the inhalation of radon more than a certain amount, it is considered that the exposure through the inhalation of radon can be reduced through normal indoor wear. Accordingly, we would like to find out the radon blocking effect of a mask worn in everyday life. Looking at the reduction rate of radon for each mask, cotton masks decreased by 33.45%, medical masks by 33.50%, KF 80 masks by 35.12%, and KF 94 masks by 37.72%. It was found that the radon blocking effect of the cotton and medical masks was somewhat inferior to that of the KF mask, but the difference was not so great that the introduction of radon into the air could be blocked to a certain level by wearing a mask.

Evaluation of the Filtration Efficiency and Facial Inhalation Resistance of Various Commercial Masks (시중에 판매되는 다양한 비인증 마스크의 분진 포집효율과 안면부 흡기저항 평가)

  • Kang, Sohyun;Kim, Soomin;Yoon, Chung Sik;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.292-301
    • /
    • 2021
  • Objectives: Wearing medical masks has been recommended since the declaration of coronavirus disease-19 (COVID-19) as a pandemic disease. Certified medical masks are evaluated according to filtration efficiency and facial inhalation resistance. However, some people use non-certified common masks. This study aimed to evaluate various non-certified commercial masks based on the certification criteria for medical masks. Methods: Twenty mask products (three anti-droplet, three disposable dental, eight fashion, three cotton, and three children's masks) were selected. For performance evaluation, filtration efficiency and facial inhalation resistance tests were conducted. The evaluation method followed the certification method for KF-certified masks of the Ministry of Food and Drug Safety (MFDS) and the N95 respirator of the National Institute for Occupational Safety and Health (NIOSH). Results: None of the 20 masks met the KF94 certification standard set by the MFDS. Four and three masks respectively met the KF80 certification standard and the N95 standard of NIOSH. Filtration efficiency was significantly higher in three-layer masks than in single layer masks. Pleated-type masks had higher filtration efficiency than cone-type masks. There was no correlation between the structure of masks and facial inhalation resistance. Conclusion: While no masks complied with the KF94 certification standard, a few masks met the KF80 and the N95 certification standards of NIOSH. Although some people wear non-certified commercial masks, protection from aerosols is not guaranteed by such masks. Evaluation of the protection efficiency of non-certified mask against microbiological infection is needed for the prevention of infectious disease.

Probiotic Mixture KF Attenuates Age-Dependent Memory Deficit and Lipidemia in Fischer 344 Rats

  • Jeong, Jin-Ju;Kim, Kyung-Ah;Ahn, Young-Tae;Sim, Jae-Hun;Woo, Jae-Yeon;Huh, Chul-Sung;Kim, Dong-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.9
    • /
    • pp.1532-1536
    • /
    • 2015
  • To investigate the memory-enhancing effect of lactic acid bacteria, we selected the probiotic mixture KF, which consisted of Lactobacillus plantarum KY1032 and Lactobacillus curvatus HY7601 (1 × 1011 CFU/g of each strain), and investigated its antilipidemic and memoryenhancing effects in aged Fischer 344 rats. KF (1 × 1010 CFU/rat/day), which was administered orally once a day (6 days per week) for 8 weeks, significantly inhibited age-dependent increases of blood triglyceride and reductions of HDL cholesterol (p < 0.05). KF restored agereduced spontaneous alternation in the Y-maze task to 94.4% of that seen in young rats (p < 0.05). KF treatment slightly, but not significantly, shortened the escape latency daily for 4 days. Oral administration of KF restored age-suppressed doublecortin and brain-derived neurotrophic factor expression in aged rats. Orally administered KF suppressed the expression of p16, p53, and cyclooxygenase-2, the phosphorylation of Akt and mTOR, and the activation of NF-κB in the hippocampus of the brain. These findings suggest that KF may ameliorate age-dependent memory deficit and lipidemia by inhibiting NF-κB activation.

Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks (보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도)

  • Han, Don-Hee;Kim, Il Soon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.