• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.032 seconds

Preparation of Precision Thin Film Resistor Sputtered by Magnetron Sputtering (IC용 초정밀 박막저항소자의 제조와 특성연구)

  • Ha, H.J.;Jang, D.J.;Moon, S.R.;Park, C.S.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1236-1238
    • /
    • 1994
  • TiAlN thin films were prepared by a multi target r.f magnetron sputtering system under different conditions. We have investigated the resistivity and T.C.R. (Temperature Coefficient of Resistance) characteristics of TiAlN films deposited on $Al_2O_3$ and glass substrates by sputtering in an $Ar:N_2$ gas mixture. We used Al and Ti metal as Target Material and $Ar:N_2$ gas as working gas. We varied the partial pressure ratio of $N_2/Ar$ from 0.2/7 to 1.0/6.2 (SCCM). And the R.F power of Ti and Al Target also were varied as 160/240, 200/200 and 240/160(W). In this experiment, we can get the precision thin film resistor with a very low T.C.R. (Temperature Coefficient of Resistance) below 25 ppm ${\Omega}/^{\circ}C$.

  • PDF

IoT Home System for Dementia Care based on Beacon Indoor Positioning (비콘 실내측위 기반 치매 환자 보호 시스템)

  • Kim, JunYeong;Jeon, SoYeon;Cho, YoonSoo;Han, HyeJung;Moon, Ho;Lee, HyungJune
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.1141-1144
    • /
    • 2017
  • 최근 고령화에 따른 치매 환자 증가 추세로 인해 실내 치매 환자 케어 시스템이 주목받고 있다. 본 논문에서는 비콘과 센서를 이용한 치매 환자의 배회 방지 및 위험 장소 접근 알림 시스템을 개발하였다. 치매 환자의 실내 위치를 추적하기 위해 비콘을 실내 곳곳에 부착하고, 치매 환자의 위험 행동을 감지하기 위해 센서를 위험지역에 설치한다. 스마트폰을 사용하여 비콘 신호를 측정하고 측정된 비콘 신호를 사용하여 치매 환자의 위치를 계산하여 치매 환자가 위험에 처했다고 판단되면 이를 간병인에게 알린다. 위 시스템을 통해 간병인의 부담을 덜고, 간병 비용을 절약할 수 있다.

Influence of Annealing treatment on the properties of B doped ZnO:Al transparent conduction films (열처리 효과에 따른 AZOB 투명 전도막의 특성)

  • Lee, Jong-Hwan;Lee, Kyu-Il;Yu, Hyun-Kyu;Lee, Tae-Yong;Kang, Hyun-Il;Jeong, Kyu-Won;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.194-194
    • /
    • 2008
  • Boron doped ZnO:Al(AZOB) thin films were prepared on glass substrates by dc magnetron sputtering. Influence of the annealing treatment on the electrical and optical properties of AZOB thin films were investigated. The lowest resistivity of $1.6\times10^{-3}\Omega$-cm was obtained at an annealing temperature of $400^{\circ}C$. The average transmittance of the films is over 80% in the visible range. It was also shown that by introducing boron impurity into AZO system improve the uniformity, the resistivity, and thermal stability of ZnO-based conducting thin films.

  • PDF

A Study on a Methodology of Determining an Appropriate Load Power Factor Effectively by the Use of Reactive Power Sensitivity and Load Duration Curve (무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구)

  • Lee, Byung Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1782-1790
    • /
    • 2012
  • In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.

A Prony Method Based on Discrete Fourier Transform for Estimation- of Oscillation Mode in Power Systems (이산푸리에변환에 기초한 Prony 법과 전력계통의 진동모드 추정)

  • Nam Hae-Kon;Shim Kwan-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.293-305
    • /
    • 2005
  • This paper describes an improved Prony method in its speed, accuracy and reliability by efficiently determining the optimal sampling interval with use of DFT (discrete Fourier transformation). In the Prony method the computation time is dominated by the size of the linear prediction matrix, which is given by the number of data times the modeling order The size of the matrix in a general Prony method becomes large because of large number of data and so does the computation time. It is found that the Prony method produces satisfactory results when SNR is greater than three. The maximum sampling interval resulting minimum computation time is determined using the fact that the spectrum in DFT is inversely proportional to sampling interval. Also the process of computing the modes is made efficient by applying Hessenberg method to the companion matrix with complex shift and computing selectively only the dominant modes of interest. The proposed method is tested against the 2003 KEPCO system and found to be efficient and reliable. The proposed method may play a key role in monitoring in real time low frequency oscillations of power systems .

Evaluation of Mental Fatigue Using Vowel Formant Analysis (모음 포먼트 분석을 통한 정신적 피로 평가)

  • Ha, Wook Hyun;Park, Sung Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Mental fatigue is inevitable in the workplace. Since mental fatigue can lead to decreased efficiency and critical accidents, it is important to manage mental fatigue from the viewpoint of accident prevention. An experiment was performed to evaluate mental fatigue using the formant frequency analysis of human voices. The experimental task was to mentally add or subtract two one-digit numbers. After completing the tasks with four different levels of mental fatigue, subjects were asked to read Korean vowels and their voices were recorded. Five vowel sounds of "아", "어", "오", "우", and "이" from the voice recorded were then used to extract formant 1 frequency. Results of separate ANOVAs showed significant main effects of mental fatigue on formant 1 frequencies of all five vowels concerned. However, post-hoc comparisons revealed that formant 1 frequencies of "아" and "어" were most sensitive to mental fatigue level employed in this experiment. Formant 1 frequencies of "아" and "어" significantly decrease as the mental fatigue accumulates. The formant frequency extracted from human voice would be potentially applicable for detecting mental fatigue induced during industrial tasks.

News Focus - Today and Tomorrow of the Korea-made NPP, SMART (뉴스초점 - 한국 토종 원자로 'SMART"의 오늘과 내일)

  • Kim, Hak-Roh
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.6
    • /
    • pp.40-44
    • /
    • 2011
  • Nuclear energy in Korea began in 1958, when the Korea's atomic energy act was formulated and the relevant organizations were founded. Since then, notwithstanding the two catastrophe like TMI and Chernobyl accident, Korea made a wise decision to expand the peaceful uses of the nuclear energy as well as to localize the essential nuclear design technology of fuel and nuclear steam supply system. This decision resulted in the success of export of nuclear power plants as well as research reactor in 2010s. The Korea's nuclear policy, which well utilized 'international crisis in nuclear business' as 'opportunity of Korea to get. nuclear technology', is believed nice policy as a role model of nuclear new-comer countries. Based upon the success story of localization of nuclear technology, Korea had an eye for a niche market, which was a basis of development of SMART, Korea-made integral PWR. The operation of a SMART plant can sufficiently provide not only electricity but also fresh water for 100,000 residents. Last two years, Korea's nuclear industry team led by the Korea Atomic Energy Research Institute completed the standard design of SMART and applied to the Korea's regulatory body for standard design approval. Now the Korea's licensing authority is reviewing the design with the relevant documents, and the design team is doing its best to realize its hope to get the approval by the end of this year. From next year, the SMART business including construction and export will be explored by the KEPCO consortium.

  • PDF

Optimal Energy Shift Scheduling Algorithm for Energy Storage Considering Efficiency Model

  • Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1864-1873
    • /
    • 2018
  • Energy shifting is an innovative method used to obtain the highest profit from the operation of energy storage systems (ESS) by controlling the charge and discharge schedules according to the electricity prices in a given period. Therefore, in this study, we propose an optimal charge and discharge scheduling method that performs energy shift operations derived from an ESS efficiency model. The efficiency model reflects the construction of power conversion systems (PCSs) and lithium battery systems (LBSs) according to the rated discharge time of a MWh-scale ESS. The PCS model was based on measurement data from a real system, whereas for the LBS, we used a circuit model that is appropriate for the MWh scale. In addition, this paper presents the application of a genetic algorithm to obtain the optimal charge and discharge schedules. This development represents a novel evolutionary computation method and aims to find an optimal solution that does not modify the total energy volume for the scheduling process. This optimal charge and discharge scheduling method was verified by various case studies, while the model was used to realize a higher profit than that realized using other scheduling methods.

The Analysis of Electrical Conduction and Corrosion Phenomena in HVDC Cooling System and the Optimized Design of the Heat Sink of the Semiconductor Devices (HVDC 냉각시스템의 전기전도현상 및 부식현상 기술 분석과 스위칭 소자의 방열판 최적 설계 검토)

  • Kim, Chan-Ki;Park, Chang-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.484-495
    • /
    • 2017
  • In HVDC thyristor valves, more than 95% of heat loss occurs in snubber resistors and valve reactors. In order to dissipate the heat from the valves and to suppress the electrolytic current, water with a high heat capacity and a low conductivity of less than 0.2 uS/cm must be used as a refrigerant of the heat sink. The cooling parts must also be arranged to reduce the electrolytic current, whereas the pipe that supplies water to the thyristor heat sink must have the same electric potential as the valve. Corrosion is mainly caused by electrochemical reactions and the influence of water quality and leakage current. This paper identifies the refrigerants involved in the ionization, electrical conductivity, and corrosion in HVDC thyristor valves. A method for preventing corrosion is then introduced. The design of the heat sink with an excellent heat radiation is also analyzed in detail.

Insulation Characteristics of High Temperature Superconducting Cable (고온 초전도 레이블의 절연 특성)

  • Kim, H.J.;Kim, J.H.;Sim, K.D.;Kim, H.J.;Cho, J.W.;Seong, K.C.;Kwag, D.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF