배전계통 이상전압 측정 시스템 구성에 관한 연구 (A Study on the Measurement Systems of Over-voltages in Distribution Systems)

  • 박상만;김준오;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.585-587
    • /
    • 1998
  • In 22.9 kV-Y distribution lines, Several kinds of over-voltages occur. These over-voltages are usually surge types except controling the bus voltages for line voltage drop. The measuring over-voltages in 22.9 kV lines is a very difficulty skill. This paper introduces the study on the measurement system of over-voltages in 22.9kV distribution lines. It has been researching in KEPCO since 1995.

  • PDF

수요의 불확실성을 고려한 예약 요금제 (Precontract Pricing considering Stochastic Demand)

  • 정혜성;김성수;박종근;최준영;홍준희;임성황
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.540-542
    • /
    • 1995
  • When precontract pricing is applied, consumers must reserve expecting the amount of electricity to use. But Consumers expecting demand has stochastic property, expecting demand may be different from real demand. To prepare for this problem, spinning reserve is needed. Now I suggest new pricing system that someone has large variance and large elacity pays high price by the accumulated penalty factor. And I suggest the accumulated penalty factor for maximizing social welfare.

  • PDF

Short-term Electrical Load Forecasting Using Neuro-Fuzzy Model with Error Compensation

  • Wang, Bo-Hyeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제9권4호
    • /
    • pp.327-332
    • /
    • 2009
  • This paper proposes a method to improve the accuracy of a short-term electrical load forecasting (STLF) system based on neuro-fuzzy models. The proposed method compensates load forecasts based on the error obtained during the previous prediction. The basic idea behind this approach is that the error of the current prediction is highly correlated with that of the previous prediction. This simple compensation scheme using error information drastically improves the performance of the STLF based on neuro-fuzzy models. The viability of the proposed method is demonstrated through the simulation studies performed on the load data collected by Korea Electric Power Corporation (KEPCO) in 1996 and 1997.

뉴톤법에 의한 최적전력 조류계산의 개선 (Optimal Power Flow Study by The Newton's Method)

  • Hwang, Kab-Ju
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.223-231
    • /
    • 1990
  • Optimal Power Flow (OPF) solution by the Newton's method provides a reliable and robust method to classical OPF problems. The major challenge in algorithm development is to identify the binding inequalities efficiently. This paper proposes a simple strategy to identify the binding set. From the mechanism of penalty shifting with soft penalty in trial iteration, an active binding set is identidied automatically. This paper also suggests a technique to solve the linear system whose coefficients are presented in the matrix from. This implementation is highly efficient for sparsity programming. Case studies for 3, 5, 14, 118 bus and practical TPC-190, KEPCO-306 bus systems are performed as well.

  • PDF

부하균등화를 고려한 배전계통의 정전복구 (Service Restoration Considering Load Balancing In Distribution Networks)

  • 최상열;김종형;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권9호
    • /
    • pp.513-520
    • /
    • 2003
  • Service restoration is an emergency control in distribution constrol centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. therefore, it requires fast computation time and high quality solutions for load balancing. In this paper. a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

절연진단용 UHF 센서 모델 설계 (A Design of UHF-Sensor for Diagnosis of Insulator)

  • 최은혁;도영회;김기채;김이국;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.115-117
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7[GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

인공지능에 의한 부하전류파형의 인식으로 화재감지 시스템 (Fire detection system by awareness of load current waveform by Neural Network)

  • 이오걸;송호신;김태우;김민회
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.301-304
    • /
    • 2001
  • In this paper, a method which can detect tracking caused by the insulation deterioration of conduct wiring, is proposed. The computer which take experiment data is learned by neural network algorithm, which has recently been used for the load recognition. The proposed method in our study can be applied to the development of several measuring equipments such as hot-line insulation tester, car earth tester for the detection of tracking under hot-line state.

  • PDF

ZVT-PWM 부스트 컨버터를 이용한 무전극 램프 구동 시스템 (Electrodeless Fluorescent Lamp System using A New ZVT-PWM boost Converter)

  • 이현무;이현우;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1175-1177
    • /
    • 2003
  • In this paper, an application of the ZVT-PWM(zero-voltage-transition) boost converter, which has great advantage on miniaturization and high power density, to the power factor correction circuit of the EFL(electrodeless fluorescent lamp) inverter is studied. The operation principles of the converter are described to identify the power factor correction characteristic of the inverter. Experimentally obtaining the high power factor above 0.99, it is verified that the power factor correction of the EFL inverter successfully achieved.

  • PDF

대형 봉상 접지전극의 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods)

  • 이복희;장근철;이동문;정동철;이승칠;안창환;정용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1849-1851
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flow into the grounding system, the ground impedance is significantly increased because of the inductive behavior. This paper presents how the impulse current works on the long vertical ground electrodes. The different shape of current was impressed between ground rods and auxiliary electrode by using impulse generator and the ground impedance was calculated from the ground potential rise.

  • PDF

22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구 (A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System)

  • 강문호;장상옥;박상만;하동혁;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.

  • PDF