• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.034 seconds

The Review of Performance Evaluation on Composite Hollow Insulator for Extra high-voltage (초고압용 Composite hollow Insulator의 성능평가검토)

  • Heo, J.C.;Choi, I.S.;Ban, S.G.;Choi, B.W.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1808-1810
    • /
    • 2001
  • Because of its advantages such as more safe better electrical properties, lighter and easier to handle etc. than conventional ceramic materials, the development and application of composite insulator to the distribution and transmission system have been rapidly increased lately. In this paper, we reviewed performance evaluation on composite hollow insulator for extra high voltage based on IEC 61462 Technical Report 2, prospected to be published as international standards of Insulator for $SF_6$ GIS, Transformer, Arrestor etc, having been prepared by IEC technical committee 36 : insulator.

  • PDF

A study on pseudomeasurement for distribution system state estimation (배전계통 상태추정위한 의사측정치에 관한 연구)

  • Choi, Seung-Kyu;Jeon, Young-Jae;KIm, Hoon;Rim, Tae-Hoon;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1076-1078
    • /
    • 1999
  • In this paper, pseudomeasurements have decided using real-time measurements and forecasting data in order to reduce the difference between accuracy of real-time measurements and pseudomeasurements. A decided pseudomeasurement by means of the presented method can look for estimated solution as compared to conventional pseudomeasurement because there is no difference between accuracy of measurements. The simulations are carried out for test systems and corresponding results are presented.

  • PDF

Feature Extraction of Fault Current using Fourier Transform on the Multi-Shot Reclosing (푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출)

  • Oh, J.H.;Yun, S.Y.;Lee, N.S.;Kim, J.C.;Bae, J.C.;Kim, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1130-1132
    • /
    • 1999
  • This paper presents the feature extraction of fault current related to the multi-shot reclosing scheme in the power distribution system. Fourier transform is used to extract the feature of the fault current waveform in the case of the temporary fault and the permanent fault. After the waveform is analyzed using Fourier transform, the magnitude spectrum and the relative variation of THD are calculated. These results are that the relative variation of THD is great in the temporary fault and is little in the permanent fault.

  • PDF

Calculation and Allocation of Transmission Loss Under Competitive Power Industry System (경쟁적 전력산업체제에서 송전손실에 대한 계산과 분배)

  • Hahn, T.K.;Kim, J.H.;Kim, S.S.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1334-1336
    • /
    • 1999
  • 전력산업의 구조개편으로 기존의 한국전력 독점체제에서 다수의 전력회사로 나누어 질 것이다. 따라서 손실과 공급의 신뢰도 확보 등의 책임분배와 비용분배의 문제가 새로이 나타날 것으로 예상된다. 손실에 대한 비용의 경우 계산법과 이러한 비용을 분배하는 방법이 중요한 문제가 되고 있다. 본 논문은 전력산업구조개편이 이미 이루어진 선진국들의 손실비용의 처리방법을 비교하였다. 그리고 손실에 대한 비용계산 방법을 모의 시스템에 각각 적용시켜보고 결과를 비교하였다.

  • PDF

Characteristics of Insulation Aging in High Voltage Cables (고압케이블의 절연열화 특성)

  • Kim, Kyeong-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

The Analysis of Weibull Distribution on the Diagnosis Technology of Used Power Cable (운용된 전력케이블의 진단기술에 대한 와이블 분포해석)

  • Lim, Jang-Seob;Noh, Sung-Ho;Kim, Ji-Sun;Lee, Jae-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.47-47
    • /
    • 2010
  • 배전계통의 사고예방 기술은 전력수요 및 증설이 증가하고 있는 상황에서 시급히 확립되어야 한다. 특히 현장에서 시공되는 케이블은 시공과정의 관리가 쉽지 않을 뿐 아니라, 시공 중 발생될 수 있는 결함들을 검출하는 방법도 제한되어 있다. 본 연구에서는 국내에 도입된 진단방법을 통계적 방법으로 분석하고 효과적으로 점검할 수 있는 방법에 관한 검토하고자 한다.

  • PDF

Development of a Fault Identification Algorithm in Distribution System Using Fuzzy Logic (Fuzzy Logic을 이용한 비전계통의 고장검출 알고리즘 개발)

  • Kim, Ho-Joon;Jung, Ho-Sung;Cho, Phil-Hun;Shin, Myung-Chul;Kim, Chang-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1465-1467
    • /
    • 1999
  • An Algorithm is devised to discriminate power distribution faults from other activites utilizing the arc activity and changes in the loading. This scheme intends to determine the cause of the transients and identify them. the discrimination algorithm was tested using recorded event data.

  • PDF

Digital Filter Design for Removing Exponentially Decaying DC-Offset Component from Relaying Signal (계통사고시 지수함수 형태로 감소하는 DC-Offset 성분을 계전신호에서 제거하는 Digital Filter 디자인)

  • Kang, Sang-Hee;Kim, Nam-Ho;Kang, Yong-Cheol;Kim, Il-Dong;Park, Jong-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.59-62
    • /
    • 1992
  • Power system fault transient signals are highly distorted due to the presence of high frequency components in the voltage and current signals and an exponentially decaying dc-offset component in the current signals. Modern protective relays have to make reliable fast decisions about the nature of a fault in the presence of such transients. To use a dc-offset removing filter makes relay algorithms much fast and reliable for detecting a fault. In this paper, several dc-offset removing filters are described, and characteristics of them are compared.

  • PDF

Development of Optical CT and PT using BSO Single Crystal (BSO를 이용한 광CT, PT 개발)

  • Shin, K.H.;Lee, B.K.;Cho, H.K.;Kim, Y.H.;Kim, Y.S.;Park, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.491-494
    • /
    • 1992
  • This paper described the development example of optical CT(Current Transformer) and optical PT (Potential Transformer) which is measurement system of current and voltage of electric power line using Electro-Optic effect and Magneto-Optic effect. We designed the optical CT of 22KV class and 154KV class and an optical PT of 22KV class. And now the filed testing is in progress in a KEPCO's substation.

  • PDF

Application Analysis of a Resistive type SFCL for Transmission Systems (EMTCD를 이용한 154kV 송전계통에서의 초전도 한류기 적용 해석)

  • Heo Tae Jeon;Bae Hyeong Thaek;Park Min Won;Yu In Keun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.409-411
    • /
    • 2004
  • The need for Fault Current Limiters (FCL) is associated with the continuous growth and interconnection of modem power systems and increase in dispersed generation facilities, which result in progressive increase in the short circuit capacity far beyond their original design capacity. Fault Current Limiters (FCL) clips the fault currents and reduces the electromechanical stresses on the network and the need to handle excessive fault currents. In addition, the reduction of the fault duration Provided by the limiter should increase the power transmission capability and improve the dynamic stability. This paper proposes the model of resistive type superconducting fault current limiter using EMTDC(Electromagnetic transients for DC analysis program). In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current in a transmission system through the EMTDC based simulation by using the modeled component of a resistive type SFCL is peformed and the detailed results are given.

  • PDF