• Title/Summary/Keyword: KEPCO System

Search Result 1,670, Processing Time 0.028 seconds

Feasibility Study for the Ghana-Mali 225kV Interconnection Project (서부아프리카 국가간 연계 송전망 타당성 조사)

  • Kim, Jong-Hwa;Lee, Chul-Hyu;Lee, Young-Gil;Choi, Sang-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.38-39
    • /
    • 2008
  • KEPCO conducted the project called the "Feasibility Study for the Han (Ghana) - Bobo Dioulasso (Burkina Faso) - Bamako (Mali) Interconnection Project" as its first African project. This paper deals with power system analysis and Transmission line and substation design of approximately 750 kilometers of the 225 kV single circuit transmission lines and six substations. The main contents of the power system analysis results and preliminary engineering design include power flow, transient stability, eigenvalue analysis, transmission line design, substation design and economic analysis.

  • PDF

A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement (해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토)

  • Gang, Ji-Won;Yang, Hae-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

Lightning Overvoltage Characteristics in Distribution System with Arrester Application (피뢰기 적용에 따른 다양한 배전계통의 뇌과전압 변화특성)

  • Kim, Sang-Kuk;Jung, Chae-Kyun;Lee, Jong-Beom;Ha, Dong-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.355-357
    • /
    • 2002
  • Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. The selection of the proper value of basic insulation level(BIL), for particular insolation components of distribution structures in specific, is very important. Lightning strikes has current risetimes ranging from 0.1 to several $\mu s$ and can produce transient overvoltages substantially greater than the BIL of many distribution systems in spite of lightning arresters. This paper describes lightning overvoltage of a 22.9kV distribution system due to lightning strike. This study will provide the information on insulation coordination studies to adopt BIL.

  • PDF

Reliability Evaluation of Power Distribution Systems Considering a Momentary Voltage Quality (순시전압 품질을 고려한 배전계통에서의 신뢰도 평가)

  • Yun, Sang-Yun;Kim, Jae-Chul;Bae, Joo-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.202-205
    • /
    • 2002
  • This paper presents the reliability evaluation methods considering the momentary voltage quality in power distribution systems. The voltage qualify phenomena deal with this paper are sustained and momentary interruptions and voltage sags. Conventional evaluation indices and methods are summarized for the sustained interruptions, and the assessment methodologies of momentary interruptions and voltage sags are proposed. The evaluation methods are divided into the analytical method and Time Sequential Monte Carlo simulation. The proposed methods are tested using the modified RBTS (Roy Billinton Test System) form and historical reliability data of KEPCO system.

  • PDF

Improvement of triggering system of impulse voltage generator for Extra high-voltage (충격전압발생기 트리거 시동장치 성능개선)

  • Heo, J.C.;Park, S.J.;Moon, I.W.;Park, J.W.;Oh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1704-1706
    • /
    • 2002
  • With increasement of use in electricity energy, quality of electric apparatus has been recognized as important factor in distribution and transmission line. Especially In laboratories, lightning and switching impulse performances of electric apparatus have been carrying out by impulse voltage generator (IVG), simulated into lightning and switching surge circuit. In this paper, we describe triggering system of impulse voltage generator(IVG) for extra high voltage, which has been newly designed.

  • PDF

Wind Analysis and Site Assessment for Test Site of 3MW Wind Power System (3MW 풍력발전시스템 개발품의 육상풍력실증단지 조성 타당성 평가를 위한 풍황 및 지형평가 연구)

  • Woo, Sangwoo;Lee, Ki-Hak;Lee, Sang-Il;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.35.2-35.2
    • /
    • 2011
  • A wind turbine power performance test is very important to wind turbine manufacturers because a wind farm developer or planner must want to define power performance characteristics and reliability of new wind turbines. Based on the IEC 61400-12-1, A wind turbine test site has to be nicely installed at flat terrain for testing. We are developing the wind power system which is IEC wind class IIa model with rated power of 3MW. KEPCO's Gochang power testing center was considered as candidates to build the test site without site calibration. This paper aims to verify the validity of the test site by using implement site assessment result that was based on IEC 61400-12-1.

  • PDF

R-type HTS-FCL Model considering transient characteristics

  • Yoon Jae Young;Lee Seung Ryul;Kim Jong Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.35-38
    • /
    • 2005
  • One of the most serious problems in KEPCO system operation is higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the resistance type HTS-FCL(High Temperature Superconductor Fault Current Limiter) can be one of the most attractive alternatives to solve the fault current problem. To evaluate the accurate transient performance of resistance type HTS-FCL, it is needed that the dynamic simulation model considering transient characteristics during quenching and recovery state. Under this background, this paper presents the EMTDC model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching and recovery phenomena by fault current injection and clearing occurs.

Transmission Pricing for System Reliability (계통신뢰도를 반영한 송전선 이용료의 산정)

  • Yoo, Chong-Il;Shin, Young-Gyun;Kim, Bal-Ho H.;Won, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.553-555
    • /
    • 2001
  • It is required to develop a rational transmission tariff structure to ensure the fair participation of the player in the market where transmission sector remains as a monopoly after the electricity industry restructuring. The objective of this study is to suggest an improved transmission rate system which classifies the line capacity into line usage and reliability capacity based on their purpose of use and reasonably allocates the costs incurred by each of them to users.

  • PDF

Small Small Signal Stability Anslysis by AMEP for Controller Parameter (제어기정수에 대한 AMEP와 대규모 전력계통에 미소신호안정도 해석)

  • Shim, K.S.;Song, S.G.;Nam, H.K.;Kim, Y.G.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.112-115
    • /
    • 2001
  • Eigenvalue perturbation theory of augmented system matrix(AMEP) is a useful tool in the analysis and design of large scale power systems. This paper describes the application results of AMEP algorithm with respect to all controller parameter of KEPCO systems. AMEP for interarea and local mode can be used for turning controller parameter, and verifying system data and linear model of controller.

  • PDF

The Calculation of Lightning Flashover rate of 345kV/154kV Transmission Tower (345kV 및 154kV 송전철탑의 뇌사고율 예측계산)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Hwang, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.452-454
    • /
    • 2001
  • This paper described the calculation results of lightning flashover rate on the 345kV and 154kV transmission system of KEPCO. The back-flashover rate and shielding failure rate was calculated by FLASH(lightning flashover rate calculation program from IEEE) and KEPRI's own program which is based on the EGM(Electro Geometrical Model) method. The estimated lightning flashover late of 345kV transmission system of double circuit was 1.0 flash per 100km-year, and the lightning flashover rate of 154kV transmission line was 2.0 flash Per 100km-year approximately.

  • PDF