• Title/Summary/Keyword: KEPCO System

Search Result 1,670, Processing Time 0.036 seconds

Parameter Design Using Probabilistic Methodology For Resistive HTS- FCL

  • Yoon, Jae-Young;Kim, Jong-Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.26-29
    • /
    • 2003
  • Nowadays, one of the serious problems in KEPCO system is much higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. As the superconductivity technology has developed, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. But the parameters of HTS-FCL should be designed optimally to have the best performance. Under this background, this paper presents the optimal design method of parameters for resistive type HTS-FCL using Monte Carlo technique.

Dynamic Coordination Strategies between HVDC and STATCOM

  • Kim, Chan-Ki;Sood, Vijay;Lee, Seok-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.892-902
    • /
    • 2009
  • This paper deals with the dynamic voltage control problem at the inverter end of a HVDC link when connected to a weak AC system which has the potential for harmonic instability and commutation failures. The dynamic voltage control problem is tackled with a STATCOM (Static Compensator), which not only provides a rapid recovery from harmonic instability and commutation failures but also offers a lower cost filter design for HVDC systems. PSCAD/EMTDC simulations are presented to validate the proposed topology and to demonstrate its robust performance.

Implementation of bypass system control for power plant simulator (발전소 제어 검증용 시뮬레이터를 위한 바이패스 계통의 제어 로직 구현)

  • Byun, Seung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1634_1635
    • /
    • 2009
  • 국산 개발 분산 제어시스템의 발전 설비에의 적용을 위해서는 시뮬레이터를 이용한 제어 시스템의 기능 및 신뢰성 등의 검증이 요구되어진다. 본 논문에서는 제어시스템 검증용 시뮬레이터를 개발하는데 있어서, 제어 모델 중 기동 초기와 급격한 부하 변동시 활용되어지는 터빈 바이패스 계통의 제어 로직을 구현하고, 발전소 모델과의 연계를 통한 시뮬레이션을 통해 구현한 제어 로직의 효용성을 보인다.

  • PDF

A Stability Estimation Method of HVDC System Using Reduced Model (축약모델을 이용한 HVDC시스템의 안정도 평가)

  • Kim Chan-Ki;Ryu Byeong-Woo;Jung Gil-Jo;Joe Seong-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.456-460
    • /
    • 2004
  • 본 논문은 HVDC시스템의 안정도와 제어 게인과의 상관관계를 다루고 있다. HVDC와 같은 시스템은 비선형적인 요소를 많이 가지고 있기 때문에 수학적인 알고리즘으로 안정도를 판별하고, 제어게인을 구하는 것이 매우 어렵기 때문에 축약된 모델링을 이용하여 제어 게인을 구하였고, 안정도를 분석하였다.

  • PDF

Identification of Energized status of Underground Power Cable (지중 전력 케이블 가압 상태 진단)

  • 김창교;홍진수;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.69-72
    • /
    • 1998
  • A study to identify the energized status of the 22.9kV underground power cable by the detection of vibration was reformed. We derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The vibration can be picked up by accelerometer sensor. A prototype was tested on the underground distribution system in Chonan Station, KEPCO. The results are presented and suggest the applicability of the detecting device.

  • PDF

Design and Tuning of Micro 5KVA Machine's AVR/PSS Robust Control Parameters (축소형 5KVA 동기발전기 AVR/PSS 강건한 제어정수 설계 및 튜닝)

  • Kim, D.J.;Moon, Y.H.;Kim, T.K.;Shin, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.165-168
    • /
    • 2000
  • This paper describes the guideline of design and tuning of practical Micro 5KVA machine's digital AVR/PSS control parameters by using the computer models and testing on-line AVR step test of laboratory simulator under the no-load or load conditions. The suggested procedures can be also applied to the large scaled machine's AVR/PSS control parameter tuning in KEPCO system.

  • PDF

Control Hierarchy Analysis of Haenam-Cheju HVDC system (해남-제주 HVDC 계통의 제어 계층 구조 분석)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1327-1330
    • /
    • 1999
  • In this paper control hierarchy of Haenam-Cheju HVDC link are analyzed and their functional specifications are summarized related to their level. The control functions for the submarine DC transmission are implemented by software programs on 16-bit parallel processor-based machines which are composed of subunits hierarchically linked each other

  • PDF

Analysis of Switching Surge in KEPCO's Distribution System (한전 실 배전계통에서의 개폐 서지 영향 분석)

  • Song, Jin-Ho;Seong, No-Kyu;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.125-126
    • /
    • 2008
  • 전력계통에서 고장, 선로가압 등으로 인하여 개폐서지가 발생할 수 있다. 따라서, 본 논문에서는 한전의 실 배전계통에서 고장으로 인한 개폐서지를 분석하였다. EMTP를 이용하여 계통을 모델링하고, 고장위치를 다양하게 변경시키면서 개폐서지에 대한 분석을 수행하였다. 개폐서지 발생 시 상하단의 상호간의 영향에 대하여 분석하였다. 분석결과 상호간의 영향은 미비함을 확인하였다.

  • PDF

Development of EMTDC for applying HTS Cable to KEPCO system (HTS 케이블의 실계통 적용을 위한 EMTDC 모델개발)

  • 윤재영;최흥관;김종율;이승렬
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.461-467
    • /
    • 2003
  • 초전도케이블은 기존 상전도 케이블에 비하여 송전용량, 관로입지, 신뢰도, 포설의 유연성, 송전손실 및 환경측면에서 많은 장점을 지니고 있어서 향후 대용량 전력 수송 및 대도시와 같은 고부하 밀도 지역에의 전력공급 방안으로서 각광받고 있다.[1] 이러한 이유로 전 세계적으로 초전도 케이블을 개발하기 위한 관련 연구가 활발하게 진행되고 있다.(중략)

  • PDF

Ancillary Service for Korean Wholesale Electricity Market (도매경쟁 전력시장에서의 계통 운용 보조서비스 적용방안(안))

  • Yoon, Jae-Young;Moon, Young-Hwan;Oh, Tae-Kyoo;Ok, Ki-Youl;Kim, Sung-Soo;Kim, Yong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.176-178
    • /
    • 2001
  • This paper presents the application draft of ancillary services for Korean Wholesale Electricity Market. This application draft of ancillary services is based on technical rules for ancillary services agreements prepared by KEMA and the present conditions of KEPCO system operations and future directions.

  • PDF