• Title/Summary/Keyword: KEPCO Power System

Search Result 1,267, Processing Time 0.033 seconds

Simplified GIS Diagnostic SYSTEM (간이형 상시 GIS 진단장치)

  • Jeong, J.K.;Choi, Y.J.;Kang, C.I.;Jang, H.K.;Gwak, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

A Method to Find Feature Set for Detecting Various Denial Service Attacks in Power Grid (전력망에서의 다양한 서비스 거부 공격 탐지 위한 특징 선택 방법)

  • Lee, DongHwi;Kim, Young-Dae;Park, Woo-Bin;Kim, Joon-Seok;Kang, Seung-Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.311-316
    • /
    • 2016
  • Network intrusion detection system based on machine learning method such as artificial neural network is quite dependent on the selected features in terms of accuracy and efficiency. Nevertheless, choosing the optimal combination of features, which guarantees accuracy and efficienty, from generally used many features to detect network intrusion requires extensive computing resources. In this paper, we deal with a optimal feature selection problem to determine 6 denial service attacks and normal usage provided by NSL-KDD data. We propose a optimal feature selection algorithm. Proposed algorithm is based on the multi-start local search algorithm, one of representative meta-heuristic algorithm for solving optimization problem. In order to evaluate the performance of our proposed algorithm, comparison with a case of all 41 features used against NSL-KDD data is conducted. In addtion, comparisons between 3 well-known machine learning methods (multi-layer perceptron., Bayes classifier, and Support vector machine) are performed to find a machine learning method which shows the best performance combined with the proposed feature selection method.

Implementation of an Inductively Coupled EM Probe System for PD Diagnosis

  • Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 2011
  • In recent years, various types of partial discharge (PD) methods such as capacitive, inductive, electromagnetic, and acoustic coupling techniques have been developed for diagnosing rotating machines. An electromagnetic (EM) probe, which is an inductively coupled type of sensor, is required for detecting corona and internal discharges during off-line tests. In this study, a new technique for enhancing the measurement sensitivities for corona and internal discharge based on an EM inductive position sensor is proposed. An EM probe that winds wires around horseshoe-shaped and cylindershaped ferrites as helices is designed and optimized for the implementation of off-line PD monitoring of the stator winding of a rotating machine. The measurement system based on this design is implemented, and it is verified from the results of the experiment performed in this study that the probe provides similar performance as existing commercial products.

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

Development of Contingency Screening Module for Transient Stability Analysis Program (과도 안정도 해석 프로그램을 위한 상정사고 스크리닝 모듈 개발)

  • Hwang, Jung-Hee;Kim, Chon-Hoe;Jang, Gil-Soo;Lee, Byung-Jun;Kwon, Sae-Hyuk;Cho, Yoon-Sung;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.335-337
    • /
    • 2005
  • The purpose of this work is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system, and to add a module for contingency screening. It concentrates on the development of Contingency Screening Module. In this thesis, a fast contingency screening algorithm SIME(Single Machin Equivalent), which is one of the Hybrid methods for the transient stability assessment is used to develop the contingency screening module. The proposed module is applied to a KEPCO system, and simulation results obtained from the program are compared to those of commercial programs.

  • PDF

Development of EMTDC model for Resistance type Fault Current Limiter considering transient characteristic (저항형초전도한류기 과도특성을 고려한 EMTDC 모델개발)

  • 윤재영;김종율;이승렬
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.1-7
    • /
    • 2003
  • Nowadays, one of the serious problems in KEPCO(Korea Electric Power Co-Operation) system is the more higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(High Voltage Direct Current-Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor -Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC(Electro-Magnetic Transient Direct Current) model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching phenomena occur.

A Study on the Construction of flexible Best Generation Mix with fuzzy Multi-criterion Function (퍼지 다목적함수(多目的函數)를 갖는 유연(柔軟)한 최적전원구성(最適電源構成)의 수립에 관한 연구(硏究))

  • Song, Kil-Yeong;NamGung, Jae-Young;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.103-105
    • /
    • 1992
  • The new approach using fuzzy linear programming with fuzzy multi-criterion is proposed for the best generation mix of a power system. A chracteristic feature of the presented approach is that not only cost but also reliability for goal function can be taken into account by using fuzzy multi-criterion and so more realistic solution can be obtained. The effectiveness of the proposed approach is demonstrated by the best generation mix problem of KEPCO-system size model which contains nuclear, coal, LNG, oil and pump-generator hydro plant in multi-years.

  • PDF

Small Small Signal Stability Anslysis by AMEP for Controller Parameter (제어기정수에 대한 AMEP와 대규모 전력계통에 미소신호안정도 해석)

  • Shim, K.S.;Song, S.G.;Nam, H.K.;Kim, Y.G.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.112-115
    • /
    • 2001
  • Eigenvalue perturbation theory of augmented system matrix(AMEP) is a useful tool in the analysis and design of large scale power systems. This paper describes the application results of AMEP algorithm with respect to all controller parameter of KEPCO systems. AMEP for interarea and local mode can be used for turning controller parameter, and verifying system data and linear model of controller.

  • PDF

Assessment of Parameters for the Resistive type Superconducting Fault Current Limiter in Distribution System (배전 시스템에서의 저항형 초전도 한류기 파라미터 산정 방법)

  • Heo, Tae-Jeon;Bae, Hyeong-Thaek;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.412-414
    • /
    • 2003
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a distribution system are studied using the EMTDC based simulation method in which a novel component for a resistive type of SFCL is presented. Through the simulation, the most suitable SFCL's application point is selected and the assessment method for the parameters of the SFCL is also recommended.

  • PDF

A Study on the Construction of the Flexible Long-Term Generation Mix under Uncertainties of Power System (전력계통(電力系統)의 불확실성(不確實性)을 포함한 유연(柔軟)한 장기전원구성(長期電源構成)의 수립에 관한 연구(硏究))

  • Song, Kil-Yeong;NamGung, Jae-Young;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.159-162
    • /
    • 1993
  • A new approach using fuzzy dynamic programming is proposed for the flexible long-term generation mix under uncertain circumstances. A characteristic feature of the presented approach is that not only fuzziness in fuel and construction cost. load growth and reliability but also many constraints of generation mix can easily be taken into account by using fuzzy dynamic programming. The method can accommodate arbitrary shape of membership function as well as the operation of pump-generator. And so more realistic solution can be obtained. The effectiveness of the proposed approach is demonstrated by the best generation mix problem of KEPCO-system which contains nuclear, coal, LNG, oil and pump-generator hydro plant in multi-years.

  • PDF