• Title/Summary/Keyword: K-shell Position

Search Result 58, Processing Time 0.026 seconds

Exterior egg quality as affected by enrichment resources layout in furnished laying-hen cages

  • Li, Xiang;Chen, Donghua;Meng, Fanyu;Su, Yingying;Wang, Lisha;Zhang, Runxiang;Li, Jianhong;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1495-1499
    • /
    • 2017
  • Objective: This study aimed to investigate the effects of enrichment resources (a perch, dustbath, and nest) layout in furnished laying-hen cages (FC) on exterior quality of eggs. Methods: One hundred and sixty-eight (168) Hy-Line Brown laying hens at 16 weeks of age were randomly distributed to four treatments: small furnished cages (SFC), medium furnished cages type I (MFC-I), medium furnished cages type II (MFC-II), and medium furnished cages type III (MFC-III). Each treatment had 4 replicates or cages with 6 hens for SFC (24 birds for each SFC) and 12 hen/cage for MFC-I, -II, and -III (48 birds for each MFC-I, -II and -III). Following a 2-week acclimation, data collection started at 18 weeks of age and continued till 52 weeks of age. Dirtiness of egg surface or cracked shell as indicators of the exterior egg quality were recorded each week. Results: The results showed that the proportion of cracked or dirty eggs was significantly affected by the FC type (p<0.01) in that the highest proportion of cracked or dirty eggs was found in MFC-I and the lowest proportion of dirty eggs in SFC. The results of this showed that furnished cage types affected both dirty eggs and cracked eggs (p<0.01). The results also indicated that not nest but dustbath lead to more dirty eggs. Only MFC-I had higher dirty eggs at nest than other FC (p<0.01). The results of dirty eggs in MFC-I and MFC-II compared with SFC and MFC-III seemed suggest that a low position of dustbath led to more dirty eggs. Conclusion: SFC design affected exterior egg quality and the low position of dustbath in FC resulted in higher proportion of dirty eggs.

Analysis of marine sediments between fishing area and non-fishing area in the shrimp beam trawl (새우조망 조업구역과 비조업구역의 해저퇴적물 분석)

  • Cho, Sam-Kwang;Yang, Yong-Soo;Cha, Bong-Jin;Seo, Young-Kyo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.208-216
    • /
    • 2012
  • The properties of sediment collected from seabed surface to 6cm depth on the four positions were analyzed to investigate turbulence of marine sediments by shrimp beam trawl. Types of sediments in the investigation area were (g)mS (slightly gravely muddy sand) and gmS (gravely muddy sand) showing high sand content, and (g)sM (slightly gravely sandy mud), gsM (gravely sandy mud) as well. It is estimated that position is more crucial factor than seasonal difference for the granularity variation of sediment in each investigation area. Finding the positional characteristics of sediment granularity was difficult before removing shells and organic matter. However, the average granularity is getting larger by going out from inland sea to open sea once those were removed. The granularity of marine sediment got narrow after processing in the fishing area for shrimp beam trawl but there was no big difference for granularity size before and after processing in the non-fishing area. This might be attributed to crushed shell particles going up and down again on the surface in the fishing area. To demonstrate the hypothesis mentioned above, the sediments driven by shrimp beam trawl need to be collected and analyzed.

Analysis of the Mechanical Behavior of Bellows for Electromagnetic Control Valve (전자기 제어 밸브를 위한 벨로우즈의 기계적 거동에 관한 연구)

  • Son, In-Seo;Hwang, Seon;Shin, Dong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.432-437
    • /
    • 2016
  • The behavior of a bellows for an electromagnetic control valve was investigated. The bellows consists of an outer metal bellows, inner spring, and metal caps. The bellows needs to have sensitive and precise motion against external loads and pressure loads in order to control the position of the valve accurately. The spring constant of the inner spring and load-displacement curve of the bellows set were measured using a test machine. The inner spring showed a linear relation between load and displacement. The bellows set showed small stiffness at small displacement, and then the stiffness slightly increased upon subsequent displacement. Based on the measured data, finite element analysis was performed. Axisymmetric conditions were applied, and shell elements were used. The effective material properties of the outer bellows material were extracted. Additional analysis was performed, and the behavior of the bellows was analyzed using the finite element model.

Fatigue Life Evaluation of Butt-Welded Tubular Joints

  • Kim, Dong-Su;Nho, In-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.34-39
    • /
    • 2003
  • Recent deepwater offshore structures in the Gulf of Mexico utilize butt welded tubular joints. Application of a welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical, as the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimation of the fatigue behavior of these tubular members in the design stage is generally condrcted by using S-N curves, as specified in the codeds and standards. Applying the stress concentration factor of the welded structure to the S-N approach often results in a very conservative assessment, because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fatigue life analysis using fracture mechanics has been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. Still, there is inconsistency when designing tubular joints using a conventional S-N approach and when specifying weld flaw acceptance criteria using fracture mechanics approach. This study developed fatigue curves that are consistent with both the S-N approach and the fracture mechanics approach. Accounting for non-uniform stress distribution and threshold stress intensity factor were key parameters in relating both approaches. A series of S-N curves, generated from the fracture mechanics approach, were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02 ). The new curves for tubular joint agree very well with the experimental results. The comparison also indicated the degree of conservatism built into the API X design curve.

Fatigue Life Evaluation of Butt-Welded Tubular Joints

  • Kim, Dong-Sup;Nho, In-Sik
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • Recent deepwater offshore structures in the Gulf of Mexico utilize butt welded tubular joints. Application of a welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical, as the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimation of the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves, as specified in the codes and standards. Applying the stress concentration factor of the welded structure to the S-N approach often results in a very conservative assessment, because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fatigue life analysis using fracture mechanics has been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. Still, there is inconsistency when designing tubular joints using a conventional S-N approach and when specifying weld flaw acceptance criteria using fracture mechanics approach. This study developed fatigue curves that are consistent with both the S-N approach and the fracture mechanics approach. Accounting for non-uniform stress distribution and threshold stress intensity factor were key parameters in relating both approaches. A series of S-N curves, generated from the fracture mechanics approach, were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02). The new curves for tubular joint agree very well with the experimental results. The comparison also indicated the degree of conservatism built into the API X design curve.

  • PDF

RADIO EMISSION FROM WEAK SPHERICAL SHOCKS IN THE OUTSKIRTS OF GALAXY CLUSTERS

  • Kang, Hyesung
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.155-164
    • /
    • 2015
  • In Kang (2015) we calculated the acceleration of cosmic-ray electrons at weak spherical shocks that are expected to form in the cluster outskirts, and estimated the diffuse synchrotron radiation emitted by those electrons. There we demonstrated that, at decelerating spherical shocks, the volume integrated spectra of both electrons and radiation deviate significantly from the test-particle power-laws predicted for constant planar shocks, because the shock compression ratio and the flux of inject electrons decrease in time. In this study, we consider spherical blast waves propagating through a constant density core surrounded by an isothermal halo with ρ ∝ r−n in order to explore how the deceleration of the shock affects the radio emission from accelerated electrons. The surface brightness profile and the volumeintegrated radio spectrum of the model shocks are calculated by assuming a ribbon-like shock surface on a spherical shell and the associated downstream region of relativistic electrons. If the postshock magnetic field strength is about 0.7 or 7 µG, at the shock age of ∼ 50 Myr, the volume-integrated radio spectrum steepens gradually with the spectral index from αinj to αinj + 0.5 over 0.1–10 GHz, where αinj is the injection index at the shock position expected from the diffusive shock acceleration theory. Such gradual steepening could explain the curved radio spectrum of the radio relic in cluster A2266, which was interpreted as a broken power-law by Trasatti et al. (2015), if the relic shock is young enough so that the break frequency is around 1 GHz.

AERODYNAMIC STUDY WITH AND WITHOUT WEARING SLEEP SPLINT FOR SNORING (코골이용 sleep splint 장착 전후의 공기역학적인 연구)

  • Jeong, Kil-Jung;Leem, Dae-Ho;Lee, Jong-Seok;Baek, Jin-A;Ko, Seung-O;Shin, Hyo-Keun;Kim, Hyun-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.321-328
    • /
    • 2007
  • If there are problems for us to sleep, we are faced with fatigue and dizziness in the day. Snoring and OSAS (obstructive sleep apnea syndrome) during sleeping are the main cause of sleep disorder. Treatments through surgical method and sleep splint can be performed to treat snoring and OSAS. Relapse of snoring and OSAS is common after treatment by surgical method. But, Recently sleep splint is frequently applied to treat snoring and OSAS with surgical treatment, because it is convenient and conservative. Sleep splint treat snoring and OSAS by ensuring airway through nose. As first step of fabrication occlusal bite is gained at a point that patient get feeling of increased nasal breathing in supined position, and next, the bite is transfered to sleep splint. This study surveyed the effect of sleep splint by questionnaire to the out-patients (the Dept. of Oral and Maxillofacial Surgery, Chonbuk National University Hospital) weared sleep splint and their partners, secondarily measured airflow through nose by aerophone II after wearing sleep splint and finally evaluated the effect of treatment of snoring and OSAS by sleep splint. The obtained result were as follows; 1. Though 'sleep splint' couldn't eliminate fundamental problems of snoring, it could improve the symptoms when patients were selected could using the 'Nakagawa's respiration method'. 2. Patients who used the sleep splint could breathe stably when patients are sleeping stably. Wearing a 'sleep splint' improved airflow by expanding the upper airway. 3. Even though sleep splint can be made with variable materials, the patients expressed the most satisfaction on the splint with '0.75mm hard shell'. 4. The 'Herbst' may allows the mandible to move the TMJ to relax. Nevertheless, some patients experienced a discomfort or irritation. 5. In Snoring and OSAS cases, it is recommended that patients should first explore non-surgical options prior to choosing a surgical treatment.

Identification and prevalence of trematode(Gen Azygia) and nematode(Gen Pingus) in Ophicephalus argus (가물치의 위장내 기생하는 흡충(Azygia속) 및 선충(Pingus속)의 동정과 감염상황)

  • Moon, Moo-hong;Lee, Eun-woo
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.147-159
    • /
    • 1998
  • A survey of the internal parasites in 115 fishes of Ophicephalus argus was carried out in Kyungpook province during the period from January 1995 to November 1997. A species of trematode from the stomach and a species of nematode from the caeca of the fishes was discovered respectively. The trematode was identified as Azygia hwangtsinyi (Tsin, 1993) and the nematode as Pingus sinensis ($Hs\ddot{u}$, 1993). The fluke was pressed at thick of 0.1mm~0.2mm between slide glasses and fixed in 70% ethyl alcohol solution. The fluke was washed with tap water after fixation and stained with hematoxylin-carmin and mounted in balsam through routine methods. The nematode was fixed in 5% formalin solution and mounted with lactophnol or glycerine jelly. Morphology : Arygia hwantsinyi ; The fluke is elongate body with approximately parallel margins and rounded extremities in pressed preparations(Fig 1). The cuticle is unarmed. The oral sucker is ventro-subterminal in position. The ventral sucker is slightly smaller than oral sucker and positioned at 14.2% of body length from the oral sucker. The cirrus sac and genital pore is in mid-ventral line, slightly anterior to the ventral sucker. The oral sucker is succeeded by a well developed muscular pharynx. It is succeeded by a short inverted Y-shaped oesophagus. The inner wall of oesophagus is consisted of many fine folded membrane. The fine tubes of esophagus pass into the intestinal heads which are distended and presented a marked borderline between the fine tube and intestinal heads. The Intestinal heads start at level of pharynx and pass caudad in a zigzag course to end quite near caudal margin. The uterine coils occupy the intercecal area between the level of the cephalic margin of the ovary and about the level of the ventral sucker. The uterus is filled with many eggs. The testes are round or oval and placed one behind the other generally a little diagonally. The posterior testis is placed at level of 75.1% of body length. The ovary is oval, placed ahead the anterior testis. The shell gland not discernible outline is contacted with ovary ahead it. The vitelline glands are consisted of small oval vesicles. The vesicles occupy extracecal regions and between a little posterior of the ventral sucker and near caudal margin. Pingus sinensis : Female ; The cuticle is smooth and the cervical alae are well developed. The mouth opening is small, triangular, and without lips. The anterior end bears four sub-medial papillae. The oesophagus is divided into a muscular and glandular portion. The nerve ring is situated just at the junction of the muscular and glandular portions of the oesophagus. The vulva which has a prominent flap, is placed behind the middle of the body about one-third of the length of the worm from the posterior extremity. The vagina is strongly muscularised and after running anteriorly about $68{\mu}$, divides itself into two broad uterine tubes with an anterior and a posterior one. There are a few eggs in the uterine tubes. The tail is slender, straight and pointed. The ovary extends almost to the posterior extremity. Male : Male is smaller than female. The tail is pointed, curved and carrying well-developed caudal alae. A prominent muscular precloacal sucker is characteristic. The spicules are equal and short. There are four pairs of pedunculated pre-anal papillae, of which the most anterior pair are situated just at the level anterior to the muscular sucker. Two pairs of pedunculated papillae are present before the anus. There are five pairs of post-anal papillae of which the most anterior pair and the second counted from the posterior end are ventral and more marked than the ones which are situated laterally.

  • PDF