• Title/Summary/Keyword: K-joint parameters

Search Result 682, Processing Time 0.029 seconds

Effect of Green Coffee Bean Extract Supplementation on Body Fat Reduction in Mildly Obese Women (경도비만 여성에서 생커피두 엑기스의 섭취에 의한 체지방 감소 효과)

  • Kim, Tae-Su;Yang, Woong-Suk;Park, So-I;Lee, Sung-Pyo;Kang, Myung-Hwa;Lee, Jae-Hwan;Park, Il-Bum;Park, Hyun-Jun;Murai, Hiromichi;Okada, Tadashi
    • Journal of the Korean Society of Food Culture
    • /
    • v.27 no.4
    • /
    • pp.407-413
    • /
    • 2012
  • In previous studies, we performed joint animal studies and clinical trials between Yonsei University and Oryza Oil & Fat Chemical Co. Ltd. We have shown that coffee bean extract has potent anti-obesity and hypotriglyceridemic activities as well as beneficial effects on body fat reduction.In this study, the effects of coffee bean extract (100 mg/capsule) on body fat reduction were evaluated in overweight/obese women (body mass index of 25~30 $kg/m^2$ or body fat > 30%) not diagnosed with any type of disease. Subjects were randomly assigned to a coffee bean extract group (n=10) or placebo group (n=10). We measured anthropometric parameters, abdominal fat distribution by computed tomography and blood components before and after the 8week intervention period. After supplementation, the coffee bean extract group showed body weight (p=0.08), body mass index (p=0.06), hip circumference (p<0.05), and upper waist circumference (p< 0.01). In addition, after 8 weeks, the coffee bean extract group showed a significant decrease in abdominal internal fat area compared to 0 weeks (0 weeks : $155.8cm^2$; 8 weeks : $145.9cm^2$, ${\Delta}$ change : $-9.9cm^2$, respectively). However, there were no significant differences in lipid profiles or serological measurements between the coffee bean extract group and placebo group. The results of our human study demonstrated that coffee bean extract supplementation for 8 weeks has beneficial effects on reducing abdominal internal fat area as well as hip and waist circumferences.

Effect of Process Parameters on Quality in Joint for Al/Steel Joining a MPW (전자기 펄스 용접을 이용한 Al/Steel 접합시 접합부 품질에 미치는 공정변수 영향)

  • Shim, Ji-Yeon;Kang, Bong-Yong;Kim, Ill-Soo;Park, Dong-Hwan;Kim, In-Ju;Lee, Kwang-Jin
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.27-27
    • /
    • 2009
  • 드라이브 샤프트는 일반적으로 엔진에서 발생된 회전력을 바퀴에 직접 전달하는 동시에 조향기능을 수행하는 자동차 부품이다. 최근에 경량화를 통한 에너지 절감을 위하여 기존 스틸소재를 알루미늄으로 대체하는 방안에 대한 연구가 집중되고 있다. 그러나 알루미늄 단일소재로 드라이브 샤프트를 제조하는 것은 비경제적이며 또한 기 개발된 자동차 부품들과의 연결을 고려하여 알루미늄 튜브와 스틸 요크의 이종금속 접합기술이 요구된다. 전자기 펄스용접은 전자기력을 이용하여 용접대상물을 고속으로 충돌시켜 용접하는 기술로서 열 발생이 적어 재료의 특성차로 인한 결함 및 변형이 발생하지 않아, 이종금속간 고품질 용접이 가능하며, 전자기 펄스 용접부의 품질과 밀접한 관계를 갖는 공정변수 경우 모재와 접합재의 재질 따라 적정 공정변수 범위가 변화되므로 공정에 따른 데이터의 축적은 대단히 중요하다. 전자기 펄스 용접을 이용한 이종금속 접합시 접합부 품질에 영향을 미치는 공정변수는 충전전압, 모재와 접합재 사이의 간격 및 접합재의 직경과 두께의 비(D/T비)로서 보고되었으며, Al/Steel 이종 금속 접합시 이들 공정변수가 접합부에 미치는 영향 및 최적의 공정변수 도출을 위한 연구는 시도되지 않았다. 따라서 본 연구는 전자기 펄스 용접기술을 이용한 Al/Steel 이종금속 접합 실험을 통하여 전자기 펄스용접의 적정성과 최적의 충전전압, 모재와 접합재 사이의 간격, D/T비를 도출하고자 한다. 전자기 펄스 용접 장치는 한국생산기술연구원과 웰메이트(주)에서 공동으로 개발한 $120{\mu}F$의 캐패시터 6개로 구성된 'W-MPW36'을 사용하였으며 이 장치의 최대충전전압과 최대접합용량은 각각 10kV, 36kJ이다. 접합재는 전기 전도율의 높은 Al 1070 파이프를 사용하였으며 모재는 기존 스틸 요크재인 SM45C 환봉을 사용하였다. 기보고된 연구를 통하여 코일과 접합재 사이의 간격이 좁을수록 높은 전자기력이 접합재에 작용하는 것을 확인하였으나 코일내 접합재와 모재 삽입 편의를 위하여 1mm로 설정하였다. 접합부의 품질 평가를 위하여 수압시험을 실시하였으며, 시험 후 접합부 단면을 주사전자현미경(SEM)을 이용하여 관찰하였다.

  • PDF

The Evaluation of Potential Hepatotoxicity by Calcium Channel Blockers, Renin-Angiotensin System Blockade and Diuretics (칼슘채널차단제, 레닌-안지오텐신시스템 차단제, 이뇨제의 잠재적 간독성 평가)

  • Kim, Jae Yun;Lee, Ok Sang;Jung, Sun Hoi;Lee, Hye-Suk;Lee, Chang Ho;Kim, Sang Geon;Lim, Sung Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.4
    • /
    • pp.330-339
    • /
    • 2012
  • Background : Hypertension is treated with both lifestyle modification and pharmacotherapy. The Seventh Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC-7), published in 2003, provides a streamlined management approach to hypertension for the primary care physician. The JNC-7 is the gold standard also in Korea. According to the JNC-7, special therapeutic considerations are recommended for high-risk individuals with compelling indications. The presence of compelling indications in any given patient should be considered when selecting specific pharmacotherapy to treat hypertension. However, in patients with compelling indications, it is unknown that hepatotoxicity is caused by Calcium Channel Blocker (CCB), one of 1st anti-hypertensive drugs. Now, the CCB is the most used 1st anti-hypertensive drug in Korea Therefore, we evaluated the changes in blood liver function parameters (ALT, AST, Total bilirubin, serum albumin) for the study group. Methods : We randomly collected and retrospectively analyzed Electronic Medical Record data (n=28,788) of patients, and who took calcium channel blockers(non-dihydropyridines; diltiazem, verapamil, dihydropyridines; amlodipine, barnidipine, benidipine, clinidipine, efonidipine, felodipine, isradipine, lacidipine, lercanidipine, nicardipine, nifedipine, nimodipine), with having liver function tests (LFTs) from July 1st 2009 to June 30th 2010 at the Seoul National University Hospital in Korea. Control groups are two antihypertensive agents: RAS blockade (ARB; candesartan, irbesartan, losartan, olmesartan, telmisartan, valsartan, ACE-I; cilazapril, enalapril, fosinopril, imidapril, perindopril, ramipril) and, Diuretics (loop; furosemide, torsemide, thiazide; hydrochlorothiazide[HCTZ], indapamide). Patients not having LFT results at these three standard points of time(baseline, during, medication, and after finishing medication) were excluded. The collected data were analyzed by using the SPSS (Version12.0) and Microsoft Excel (Version2007). Results : 711 patients who were treated CCB (297), RAS blockade (232) or Diuretics (182) monotherapy were selected for the study. In selected patients, liver damage degree(changes of each LFTs value) was higher in diuretics group than other groups, followed by RAS blockade and CCB. In diuretics group's was loop-diuretics group was higher than thiazide-diuretics group. In CCB group, Nondihydropyridine-CCB's damage degree was higher than Dihydropyrine-CCB's that. Conclusions : Despite the limitations due to the retrospective study, among patients with abnormal LFTs, the use of CCBs led to a less liver damage than other 1st anti-hypertensive agents. It can be recommended CCBs as one of the initial treatments of hypertension in patients with liver disease.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

Evaluation and Test Method Characterization for Mechanical and Electrical Properties in BGA Package (BGA 패키지의 기계적${\cdot}$전기적 특성 평가 및 평가법)

  • Koo Ja-Myeong;Kim Jong-Woong;Kim Dae-Gon;Yoon Jeong-Won;Lee Chang-Yong;Jung Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.289-299
    • /
    • 2005
  • The ball shear force was investigated in terms of test parameters, i.e. displacement rate and probe height, with an experimental and non-linear finite element analysis for evaluation of the solder joint integrity in area array packages. The increase in the displacement rate and the decrease in the probe height led to the increase in the shear force. Excessive probe height could cause some detrimental effects on the test results such as unexpected high standard deviation and probe sliding from the solder ball surface. The low shear height conditions were favorable for assessing the mechanical integrity of the solder joints. The mechanical and electrical properties of the Sn-37Pb/Cu and Sn-3.5Ag/Cu BGA solder joints were also investigated with the number of reflows. The total thickness of the intermetallic compound (IMC) layers, consisting of Cu6Sn5 and Cu3Sn, was increased as a function of cubic root of reflow time. The shear force was increased up to 3 or 4 reflows, and then was decreased with the number of reflows. The fracture occurred along the bulk solder, in irrespective of the number of reflows. The electrical resistivity was increased with increasing the number of reflows.

  • PDF

Inflammatory Breast Cancer: a Single Centre Analysis

  • Gogia, Ajay;Raina, Vinod;Deo, Suryanarayan Vishnu;Shukla, Nootan Kumar;Mohanti, Bidhu Kalyan;Sharma, Daya Nand
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3207-3210
    • /
    • 2014
  • Background: Inflammatory breast cancer (IBC) is an aggressive form of locally advanced breast cancer characterized by rapidly progressive breast erythema, pain and tenderness, oedema and paeu d'orange appearance. It accounts for 1-3% of all newly diagnosed cases of breast cancer in the west. Data on IBC from India are lacking. The aim of our study was to assess the clinical-pathological parameters and outcome of IBC at, All India Institute of Medical Sciences, a large tertiary care centre. Materials and Methods: We screened 3,650 breast cancer cases registered from January 2004 to December 2012 and found 41 cases of IBC. Data included demographics as well as clinical, radiological and histopathological characteristics, and were collected from clinical case records using the International Classification of Diseases code (C-50). Patients who presented with IBC as a recurrence, or who had a neglected and advanced breast cancer that simulated an IBC were excluded from this study. Results: The median age was 45 years (range 23-66). The median duration of symptoms was 5 months. The American Joint Committee on Cancer stage (AJCC) distribution was Stage III - 26 and IV - 15 patients. Estrogen receptor (ER), progesterone receptor (PR) positivity and human epidermal growth factor receptor 2 (HER2/neu) positivity were 50%, 46% and 60%, respectively. Triple negativity was found in 15% of the cases. All the non metastatic IBC patients received anthracycline and/ or taxane based chemotherapy followed by modified radical mastectomy, radiotherapy and hormonal therapy as indicated. Pathological complete remission rate was 15%. At a median follow-up of 30 months, the 3 year relapse free survival and overall survival were 30% and 40%respectively. Conclusion: IBC constituted 1.1% of all breast cancer patients at our centre. One third of these had metastatic disease at presentation. Hormone positivity and Her2 neu positivity were found in 50% and 60% of the cases, respectively.

Flexural Test for Prefabricated Composite Columns Using Steel Angle and Reinforcing Bar (앵글과 철근을 조립한 PSRC 합성기둥의 휨 실험)

  • Eom, Tae-Sung;Hwang, Hyeon-Jong;Park, Hong-Gun;Lee, Chang-Nam;Kim, Hyoung-Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.535-547
    • /
    • 2012
  • PSRC column is a concrete encased steel angle column. In the PSRC column, the steel angles placed at the corner of the cross-section resists bending moment and compression load. The lateral re-bars welded to steel angles resist the column shear and the bond between the steel angle and concrete. In the present study, current design procedures in KBC 2009 were applied to the flexure-compression, shear, and bond design of the PSRC composite column. To verify the validity of the design method and failure mode, simply supported 2/3 scaled PSRC and correlated SRC beams were tested under two point loading. The test parameters were the steel angle ratio and lateral bar spacing. The test results showed that the bending, shear, and bond strengths predicted by KBC 2009 correlated well with the test results. The flexural strength of the PSRC specimens was much greater than that of the SRC specimen with the same steel ratio because the steel angles were placed at the corner of the column section. However, when the bond resistance between the steel angle and concrete was not sufficient, brittle failures such as bond failure of the angle, spalling of cover concrete, and the tensile fracture of lateral re-bar occurred before the development of the yield strength of PSRC composite section. Further, if the weldability and toughness of the steel angle were insufficient, the specimen was failed by the fracture of the steel angle at the weld joint between the angle and lateral bars.

Crystallographical Characteristics of Solar Salts Produced from Jeonnam Area by X-Ray Diffraction Technique (X선 회절법에 의한 전남지역 천일염의 결정학적 특성)

  • Jeong, Byung-Jo;Kim, Yong;Kim, Chang-Dae;Hyun, Seung-Cheol;Ham, Gyung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1284-1288
    • /
    • 2009
  • Identification of various inorganic compound crystals contained in solar salts, which are produced from 12 areas of Jeonnam, was firstly made by the X-ray diffraction (XRD) technique. The analysis of the XRD spectra was carried out on the basis of Joint Committee on Powder Diffraction Standards (JCPDS) data and the results of Energy Dispersive X-ray Spectrometer (EDX) measurements. In particular, the analysis of the XRD spectra supported that each solar salt contains $Na_2S$ (Shinan Jeungdo and Sinui), $KMgCl_3$ (Shinan Bigeum), $Ca(ClO_3)_2$ (Shinan Docho), $CaAl_4O_7$ (Haenam Songji), $CaSiO_3$ and $CaCl_2$ (Goheung) as inorganic compound crystals, which have not been reported for the solar salts. Also, the XRD results indicated that the solar salts maintain a cubic NaCl crystal structure without any change of lattice parameters etc. However, it was shown in the Field Emission Scanning Electron Microscope (FE-SEM) images that an external form of the solar salts has a lamination layer shape of a cubic structure, which is different from a simple cubic form for the purified salts and the reagent NaCl.

The Effect of Speed-dependent with Body Weight Supported Treadmill Training on the Ambulation of Stroke (속도-의존적 체중지지 트레드밀 보행이 뇌졸중 환자의 보행에 미치는 영향)

  • Kim, Jwa-Jun;Rho, Min-He;Goo, Bong-Oh;Ahn, So-Youn
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.339-350
    • /
    • 2005
  • This study is the quasi-experimental study on the gait training rehabilitation. The purpose of this study is to prepare the baseline data for most suitable of gait while we were scrutinizing how the walking characters, functional walking ability, gait quality of stroke patients were affected by the gait on BWSTT (Body Weight Supported Treadmill Training) through the change of treadmill velocity and body weight support. To accomplish this purpose, this study used thirty subjects, more than 3 months post stroke, for rehabilitation who were divided between two gait training groups they received the neurophysiological physical therapy. For 6 weeks, 5 times a week for 15 minutes per session, the BWSTT group participated in 30 sessions structured speed-dependent treadmill training with 30% body weight supported, and the ratio of body weight support was gradually decreased as the patients advanced the capability of more self-support. The OGT(Over Ground Training) group received the same quantity of equal sessions like BWSTT. Firstly, we measured the absolute improvement of walking velocity (m/s), capacity(min/m) and cadence(steps/min) among walking characters. Secondly, we measured the functional walking ability such as Functional Ambulatory Category(FAC, score out of 5), Modified Motor Assesment Scale(MMAS, score out of 6) and Gait Quality Chart(score out of 41). Data analysis was performed with using SPSS 10.0 win program. The descriptive analysis was used to obtain average and standard deviation. The independent t-test and the paired t-test were used to compare both the groups about pre and post training test. Treatment effects were established by pre and post assessment. Subjects tolerated the training well without side-effects. Therefore, the results of this study were as follows; 1. There was a more significant difference from the improvement of walking velocity(0.09m/s), endurance(4.53min/m), cadence(4.20steps/min), FAC(0.26score), MMAS(0.33 score) and hip joint and pelvic of gait quality(0.39 score) ever before in the BWSTT group(p<.05). 2. There was a more significant increase from the walking velocity(0.01m/s) in the OGT group(p<.05). 3. There was a more statistical significant increase from comparing the average of walking velocity in both groups ever before(0.42m/s in BWSTT group and 0.31m/s in OGT group)(p<.05). There was a statistical significant difference from the average of cadence in both groups(61.87step/min in BWSTT group and 3.60steps/min in OGT group)(p<.05). As we can see from above, the findings suggest that BWSTT may be more effective than the OGT for improving some gait parameters such as gait velocity and cadency. This conclusion also suggest that BWSTT is more effective for the improvement of gait of stroke patients.

  • PDF

The Comparative Analysis of Wearing Roller Shoes and Jogging Shoes on Kinematic Characteristics in the Lower Extremity during Walking (롤러 신발과 조깅 신발 착용 후 보행 시 하지 분절의 운동학적 특성 비교 분석)

  • Jang, Jae-Ik;Chae, Woen-Sik;Kang, Nyeon-Ju;Yoon, Chang-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.399-406
    • /
    • 2009
  • The purpose of this study was to compare the effect of wearing roller shoes and jogging shoes on kinematic characteristics in lower extremity during walking. Eight male middle school students(age: $15.0{\pm}0.0^{\circ}$ yrs, height $175.9{\pm}6.6cm$, weight: $616.3{\pm}84.9$ N) who have no musculoskeletal disorder were recruited as the subjects. Temporal parameters, step length, stride length, center of mass, velocity of CM, angle of segment, angular velocity and range of motion were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions(p < .05). The results showed that stride length and velocity of CM in wearing roller shoes were significantly less than those found in wearing jogging shoes. These indicated that walking patterns may be changed by different shoe conditions and unstable braking condition because of wheel. Angle of ankle joint at LHC1 and LHC2 in wearing roller shoes was greater than the corresponding value for wearing jogging shoes. It seems that the ankle joints are locked in an awkward fashion at the heel contact to compensate for imbalance. Otherwise, dorsi flexion was not produced at the heel contact point in wearing roller shoes.