COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

인버터 저항 점용접 장치의 PWM제어에 관한 연구 (Study on PWM Control in Inverter Resistance Spot Welding)

  • 권효철;최용범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.169-171
    • /
    • 2006
  • Nowadays, inverter welding is risen in spot welding, because can secure productivity. This study made changed output wave form of inverter welding equipment by several forms and measured electric current that pass to the second of transformer for welding. Purpose of study is finding electric current of most suitable form. Also, studied applies PID control in electric current control of inverter resistance weld device and heightens electric current precision.

  • PDF

CMOS Inverter의 Substrate Current를 줄이는 Layout 설계 (New Layout Design Concept for Suppressing the Substrate Current in CMOS Inverter)

  • 박흥준;김충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.407-410
    • /
    • 1987
  • A layout design concept which suppress the substrate current generated during the switching transients of an CMOS inverter is presented. The amount of hot carriers and the peak value of substrate current can be reduced by changing the device geometry ratio of driver and load device of an CMOS inverter.

  • PDF

고효율 인버터 프로그램의 수용가 반응 조사분석 (Survey and Analysis of Customer Behavior on High Efficiency Inverter Program)

  • 박종진;곽미애;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.674-676
    • /
    • 2004
  • This paper analyzes the customer behavior on high efficiency inverter program from three angles, that is, rebates, electricity rates and the cost of measures. After deregulation, the importance of high efficiency DSM programs has been more and more increased. Especially, the inverter program is one of the most high efficiency DSM program, so it is needed the policy to promote the inverter program diffusion.

  • PDF

외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성 (The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

고속 SRM 구동시스템 설계 (Design of High Speed Drive)

  • 김태형;안영주;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.95-98
    • /
    • 2006
  • This paper proposes high speed SRM drive system for blower with a new 4-level inverter and precise excitation position generator. For the high speed blower, a proper inverter and control method are proposed and the output characteristics are analyzed. In order to get a fast build-up and demagnetization of excitation a current, 4-level inverter system is proposed. The proposed 4-level inverter has additional charge capacitor, power switch and diode in the conventional asymmetric converter. The charged high voltage is supplied to the phase winding for fast current build-up, and demagnetization current is charged to additional capacitor of 4-level inverter. In addition, a precise excitation position generator can reduce turn-on and turn-off angle error according to sampling period of digital control system. The proposed high speed SRM drive system is verified by computer simulation and experimental result.

  • PDF

NPC형 3레벨 인버터 과변조영역운전 (NPC Type 3 Level Inverter Operation in Overmodulation Region)

  • 이재문;최재호;이은규;염상구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.194-197
    • /
    • 2007
  • This paper proposes a linearization technique for the 3 level NPC type inverter, which increases the linear control range of inverter up to the 6-step inverter. The overmodulation range is divided into two modes depending on the modulation index(MI), In mode I, the reference angles are derived from the Fourier series expansion of the reference voltage corresponds to the MI. In mode II, the holding angles are also derived in the same way. Therefore, it is possible to obtain the linear control and the maximized utilization of PWM inverter output voltage.

  • PDF

평판 유도발열체의 거리·주파수 가변특성에 관한 연구 (A study on the Distance and Frequency Variable Characteristics of Flat Plate Induction Heating Element)

  • 우형균;신대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.68-74
    • /
    • 2013
  • Induction-heated system is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. This technique is used high frequency inverter. By using high frequency inverter high frequency in the range of kHz can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed analysis of characteristics according to the each frequency and produced Flat plate induction heating system using 1.5kW-class half-bridge resonant inverter. In addition, operating characteristics of the system to changes in the distance between the coil and the heater, applications of system are also discussed.

Auxiliary Resonant Commutated Leg Snubber Linked 3-Level 3-Phase Voltage Source Soft-Switching Inverter

  • Yamamoto, Masayoshi;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권2호
    • /
    • pp.90-98
    • /
    • 2003
  • This paper presents a performance analysis in steady-state of a novel type Auxiliary Resonant Commutation Snubber-linked 3-level 3-phase voltage source soft switching inverter suitable and acceptable for high-power applications in comparison with other three types of 3-level 3-phase voltage source soft switching inverters. This soft switching inverter operation which can operate under a condition of Zero Voltage Switching (ZVS). The practical steady -state performances of this inverter are illustrated and evaluated on the basis of the experimental results.

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.