• Title/Summary/Keyword: K-duct

Search Result 1,354, Processing Time 0.03 seconds

A study on the acoustic performance evaluation of heat recovery ventilator with a sound absorbing duct (흡음덕트 부착 열회수형 환기장치의 음향성능 평가에 관한 연구)

  • Bae, Myung-Whan;Song, Jun-Young;Park, Hui-Seong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.468-475
    • /
    • 2016
  • The purpose of this study is to investigate the acoustic problems of the conventional heat recovery ventilator and to suggest the methods of noise reduction from a heat recovery ventilator according to the installed location. The noise level, in this study, was measured and discussed as the parameters of size, wind volume and sound absorbing duct length for a heat recovery ventilator based on domestic and international related standards. It is found, as a result, that almost all of noise levels from the small and medium heat recovery ventilators without the sound absorbing duct in the anechoic chamber were higher than the noise standard value of 50 dB(A) regardless of the wind volume, and the noise levels went down when a sound absorbing duct was installed. In addition, the sound pressure level relative to frequency bands according to the length of sound absorbing duct was generally decreased, as the length of sound absorbing duct in the small and medium heat recovery ventilators was big, and the sound pressure level was generally increased, as the wind volume was great.

CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector (사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석)

  • Koo, Seongmo;Oh, Wonchul;Chang, Hyuksang
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

Effects of Aspect Ratio on Local Heat/Mass Transfer in Wavy Duct (열교환기 내부 유로 종횡비 변화에 따른 국소 열/물질전달 특성 고찰)

  • Jang In Hyuk;Hwang Sang Dong;Cho Hyung Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.569-580
    • /
    • 2005
  • The present study investigates the convective heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger. The effects of duct aspect ratio and flow velocity on the heat/mass transfer are investigated. Local heat/mass transfer coefficients on the corrugated duct sidewall are determined using a naphthalene sublimation technique. The aspect ratios of the wavy duct are 7.3, 4.7 and 1.8 with the corrugation angle of $145\Omega$. The Reynolds numbers, based on the duct hydraulic diameter, vary from 300 to 3,000. The results show that at the low Re(Re $\leq$ 1000) the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, non-uniform heat/mass transfer coefficients distributions appear. As the aspect ratio decreases, the number of cells formed by secondary vortices are reduced and secondary vortices and comer vortices mix due to decreased aspect ratio at Re$\leq$1000. At Re >1000, the effects of corner vortices become stronger. The average Sh for the aspect ratio of 7.3 and 4.7 are almost same. But at the small aspect ratio of 1.8, the average Sh decreases due to decreased aspect ratio. More pumping power (pressure loss) is required for the larger aspect ratio due to the higher flow instability.

A Case of Spontaneous Perforation of the Common Bile Duct in Infant (영아에서 발생한 총담관 자연 천공 1례)

  • Nam, Ki Se;Kim, Jong Min;Chung, Ki Sup;Han, Seok Joo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.284-288
    • /
    • 2004
  • Spontaneous perforation of the biliary duct is a rare disease that must be treated immediately when diagnosed in infancy. This disease must be suspected in a previously healthy infant who suddenly has abdominal distension, ascites, and intermittent jaundice. The best way to diagnose the leakage of bile in a clinically stable infant is to use radionuclide hepatobiliary scan. In most cases, however, the diagnosis of the perforation of common bile duct is frequently made during the procedure of operative cholangiogram. The prognosis is usually good with early diagnosis. We experienced an infant of 4 months of age who presented with sudden abdominal distension, jaundice and acholic stool, and confirmed the diagnosis of perforation of common bile duct through operative cholangiogram with t-tube insertion. We report a case of spontaneous perforation in an infant with review of the literatures.

  • PDF

A Case of Lingual Thyroglossal Duct Cyst Treated by CO2 Laser via Transoral Approach (경구강 CO2 레이저를 이용하여 치료한 설갑상설관 낭종 1예)

  • Kim, Tae Hwan;Park, Jin Su;Lee, Sang Hyuk;Jin, Sung Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.2
    • /
    • pp.74-77
    • /
    • 2015
  • A lingual thyroglossal duct cyst(LTGDC) is a rare congenital anomaly that account for only 0.5% to 2% of total thyroglossal duct cyst. LTGDC is frequently associated with respiratory problem in infants and pharyngeal foreign body sensation or dysphagia in adults. Because of its location and characteristics, lingual thyroid, dermoid cyst, and vallecular cyst should be included in differential diagnosis. Standard treatment for thyroglossal duct cyst is sistrunk's operation, but in terms of LTGDC, because of its location and cosmetic reasons, different kinds of treatments such as electrical cauterization, $CO_2$ laser, Robort surgery via transoral approach have been introduced. Recently authors encountered 21 years old woman with LTGDC and the mass was removed successfully via transoral approach using $CO_2$ laser. We report the clinical course with review of the literature.

  • PDF

Fine Needle Aspiration Cytology of Salivary Duct Carcinoma - A Case Report - (타액선 관암종의 세침 흡인 세포학적 소견 - 1예 보고 -)

  • Park, A-Young;Kim, Hyun-Jung;Kim, Dong-Won;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 1997
  • Salivary duct carcinoma is rare high grade adenocarcinoma, arising from larger excretory duct in major salivary gland, resembling the ductal carcinoma of the breast histologically. We report a case of salivary duct carcinoma of left parotid gland in which fine needle aspiration cytology was performed. Cytologic examination revealed 1) moderate cellularity, 2) flat sheets or three dimensional, tightly cohesive clusters on the necrotic background, 3) sometimes cribriform or papillary configuration, 4) polygonal or cuboidal cells with moderate anisonucleosis with abundant, granular and eosinophilic cytoplasm, 5) round to oval nuclei with irregular chromatin clumps, and 6) 1 or 2 inconspicuous nucleoli. Histologically, the tumor is mainly composed of cribriform intraductal component with central comedonecrosis, and small foci of infiltrating component including well differentiated ductal structures or irregular sheets in a desmoplastic stroma.

  • PDF

Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses (초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가)

  • Kim, Young-Bae;Kim, Jae-Hong;Sung, Jae-Yong;Lee, Myeong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

A Case Study on the Bartholin's Duct Abscess treated by DahuangMudan-Tang (대황모단탕(大黃牡丹湯)으로 치료한 만성 바르톨린관(管) 농양(膿瘍)(음종(陰腫)) 환자(患者) 치험(治驗) 1례(例))

  • An, Se-Bin
    • 대한상한금궤의학회지
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2012
  • Objectives : This research is to prove the effectiveness of DahuangMudan-Tang(大黃牡丹湯) in curing the Bartholin's duct abscess Methods : to achieve the goal of this research, the patient was diagnosed as 'abscess(腫膿)' treatabling by Dahuang(大黃) in GoBeob-medicine(古法醫學). I gave Dahuang Mudan-Tang(大黃牡丹湯) to the selected patient and observed the progress Results : the results indicate the followings 1. After the treatment with DahuangMudan-Tang(大黃牡丹湯), the symptoms of the Bartholin's duct abscess was significantly improved. 2. The external medicine with DahuangMudan-Tang(大黃牡丹湯) was more effective to cure the Bartholin's duct abscess.

NUMERICAL SIMULATION OF INCOMPRESSIBLE LAMINAR ENTRY FLOWS IN A SQUARE DUCT OF $90^{\circ}$ BEND BY UNSTRUCTURED CELL-CENTERED METHOD (비정렬 셀 중심 방법에 의한 정사각형 단면을 갖는 $90^{\circ}$ 곡관 층류유동의 수치해석)

  • Myong H. K.;Kim J. E.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.81-85
    • /
    • 2005
  • Three-dimensional steady incompressible laminar entry flows in a square duct of $90^{\circ}$ bend are numerically simulated by a new solution code(PowerCFD) using unstructured cell-centered method. Solutions are obtained with three unstructured grid types of hexahedron, prism and hybrid at a Reynolds number, based on the hydraulic diameter and bulk velocity, of 790. Interesting features of the flow are presented in detail. Detailed comparisons between the computed solutions and the available experimental data are given mainly for the velocity distributions at cross-sections in a $90^{\circ}$ bend of a square duct with fully-developed entry flows. It is found that the code is capable of producing the nature of laminar flow in curved square duct with no grid type dependency.

  • PDF