• Title/Summary/Keyword: K-RDT

Search Result 31, Processing Time 0.026 seconds

Structural Performance Verification of RDT Girder Bridge Feasible to Fill with Planting Ground (식재기반을 담는 RDT 거더교의 구조성능 검증)

  • Ha, Tae-Yul;Han, Jong-Wook;Yang, In-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2219-2228
    • /
    • 2015
  • The proposed RDT(Reversed Double T) girder bridge is suitable to eco corridor, because of its cross section which resembles Korean alphabet vowel "ㅛ". The total height and cost of bridge would be reduced for its inner space containing some of plant soil. In this study, the performance of the RDT girder was assessed by comparing results of static test with those of nonlinear analysis. The cracking load of the RDT girder was evaluated more than two times of design load.

Development of a Rapid Diagnostic Test Kit to Detect IgG/IgM Antibody against Zika Virus Using Monoclonal Antibodies to the Envelope and Non-structural Protein 1 of the Virus

  • Kim, Yeong Hoon;Lee, Jihoo;Kim, Young-Eun;Chong, Chom-Kyu;Pinchemel, Yanaihara;Reisdorfer, Francis;Coelho, Joyce Brito;Dias, Ronaldo Ferreira;Bae, Pan Kee;Gusmao, Zuinara Pereira Maia;Ahn, Hye-Jin;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.1
    • /
    • pp.61-70
    • /
    • 2018
  • We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.

Seroprevalence of Toxoplasmosis with ELISA and Rapid Diagnostic Test among Residents in Gyodong-do, Inchon city, Korea: A Four-Year Follow-up

  • Kim, Yeong Hoon;Lee, Ji hoo;Ahn, Seong kyu;Kim, Tong-Soo;Hong, Sung-Jong;Chong, Chom-Kyu;Ahn, Hye-Jin;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.3
    • /
    • pp.247-254
    • /
    • 2017
  • ELISA has been used for the diagnosis of toxoplasmosis, but it is being gradually replaced by a rapid diagnostic test (RDT). We compared and analyzed ELISA and RDT results using the sera collected during 4 consecutive years from residents of Gyodong-do (Island), Incheon-city, Korea. Sera from 921, 993, 940, and 838 adult residents were collected on a yearly basis (2010-2013). ELISA was performed by using a crude extract of T. gondii RH strain antigen and IgG/IgM RDT mounted with recombinant fragment of major surface antigen (SAG1), GST-linker-SAG1A, were applied to the sera. Comparison between groups was analyzed by the Student's t-test. The positive seroprevalence surged from 14.7% (135/921, 2010), 23.1% (231/993, 2011), 23.6% (222/940, 2012), and 32.1% (269/838, 2013) by ELISA. In contrast, RDT showed a more moderate increasing trend from 21.7% (200/921, 2010), 25.5% (253/993, 2011), 28.9% (272/940, 2012) and 33.1% (277/838, 2013). Discrepancies between ELISA and RDT were noted near the cut-off value. At the OD 0.15-0.24 range, RDT could detect 16.1% (169/1051) more positives, which suggests an early or acute toxoplasmosis, but at the OD 0.25-0.34 range, ELISA could detect 35.9% (92/256) more positives of possible chronic infections. Over the OD > 0.35 ELISA and RDT agreed in the majority of the cases. This surge in seroprevalence may be caused by the organic agriculture in addition to eating behavior or increase in pets among Koreans. These facts may be applied on a full-scale national survey using RDT to supplement ELISA to define the characteristics of the infection.

A Rapid Diagnostic Test for Toxoplasmosis using Recombinant Antigenic N-terminal Half of SAG1 Linked with Intrinsically Unstructured Domain of GRA2 Protein

  • Song, Kyoung Ju;Yang, Zhaoshou;Chong, Chom-Kyu;Kim, Jin-Soo;Lee, Kyung Chan;Kim, Tong-Soo;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.503-510
    • /
    • 2013
  • Toxoplasma gondii is an apicomplexan parasite with a broad host range of most warm-blooded mammals including humans, of which one-thirds of the human population has been infected worldwide which can cause congenital defects, abortion, and neonatal complications. Here, we developed a rapid diagnostic test (RDT) for T. gondii infection. Antigenic N-terminal half of the major surface antigen (SAG1) was linked with intrinsically unstructured domain (IUD) of dense granule protein 2 (GRA2). The recombinant GST-GRA2-SAG1A protein was successfully expressed and purified as 51 kDa of molecular weight. Furthermore, antigenicity and solubility of the rGST-GRA2-SAG1A protein were significantly increased. The overall specificity and sensitivity of GST-GRA2-SAG1A loaded RDT (TgRDT) were estimated as 100% and 97.1% by comparing with ELISA result which uses T. gondii whole cell lysates as the antigen. The TgRDT tested with Uganda people sera for field trial and showed 31.9% of seroprevalence against T. gondii antibody. The TgRDT is proved to be a kit for rapid and easy to use with high accuracy, which would be a suitable serodiagnostic tool for toxoplasmosis.

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

Improvement of Thunderstorm Detection Method Using GK2A/AMI, RADAR, Lightning, and Numerical Model Data

  • Yu, Ha-Yeong;Suh, Myoung-Seok;Ryu, Seoung-Oh
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.41-55
    • /
    • 2021
  • To detect thunderstorms occurring in Korea, National Meteorological Satellite Center (NMSC) also introduced the rapid-development thunderstorm (RDT) algorithm developed by EUMETSAT. At NMCS, the H-RDT (HR) based on the Himawari-8 satellite and the K-RDT (KR) which combines the GK2A convection initiation output with the RDT were developed. In this study, we optimized the KR (KU) to improve the detection level of thunderstorms occurring in Korea. For this, we used all available data, such as GK2A/AMI, RADAR, lightning, and numerical model data from the recent two years (2019-2020). The machine learning of logistic regression and stepwise variable selection was used to optimize the KU algorithms. For considering the developing stages and duration time of thunderstorms, and data availability of GK2A/AMI, a total of 72 types of detection algorithms were developed. The level of detection of the KR, HR, and KU was evaluated qualitatively and quantitatively using lightning and RADAR data. Visual inspection using the lightning and RADAR data showed that all three algorithms detect thunderstorms that occurred in Korea well. However, the level of detection differs according to the lightning frequency and day/night, and the higher the frequency of lightning, the higher the detection level is. And the level of detection is generally higher at night than day. The quantitative verification of KU using lightning (RADAR) data showed that POD and FAR are 0.70 (0.34) and 0.57 (0.04), respectively. The verification results showed that the detection level of KU is slightly better than that of KR and HR.

Development of Mixed Reliability Demonstration Test Plans (혼합형 신뢰성 실증시험계획의 개발)

  • Seo, Sun-Keun
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.170-175
    • /
    • 2015
  • Reliability demonstration tests (RDT's) are widely employed in design verification and process validation stages of industry. New mixed attribute-variable RDT plans that compromise demerits of the corresponding zero and zero or one failure plans which are common in practice are developed for the exponential distribution. The proposed mixed plans are compared with the typical RDT plans in terms of probability of acceptance and expected test termination time. A numerical example is provided to illustrate the mixed plans and a procedure to extend these plans to the Weibull distribution with known shape parameter is also presented.

Statistical Design of Two-Stage Reliability Demonstration Tests (2단계 신뢰성 실증시험의 통계적 설계)

  • Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.2
    • /
    • pp.313-319
    • /
    • 2011
  • In design verification and process validation stages, reliability demonstration tests(RDT's) are common practice in industry, A new two-stage RDT that is known to be more efficient than a corresponding single-stage one in terms of expected test duration for Weibull distribution is proposed. Zero or one failure two-stage plans to minimize expected test duration under Type I and hybrid censoring subject to satisfying consumer's risk at a specified reliability target are developed and a numerical example is provided to illustrate the proposed two-stage RDT plans and compared with other one- and two-stage plans.

Anti-obesity Effects of Gambibang-2 on the Obese-Mice Induced by High-fat Diet (감비(減肥) 2호방이 고지방식이로 유도된 비만 생쥐에 미치는 영향)

  • Han, Joo-Won;Heo, Dong-Seok;Yoon, Il-Ji;Oh, Min-Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.837-847
    • /
    • 2009
  • In order to investigate the anti-obesity effects of Gambibang-2(here in after referred to GBB2) on the obese gene and obese inhibitory, C57BL/6 mice were induced by high fat diet. C57BL/6 mice were divided into four groups(normal, high fat diet with control, high fat diet with Reductil(here in after referred to RDT), high fat diet with GBB2 extract) and fed for 8 weeks. And observed that, body weight change, the weight change of the adipocytes in body and liver, total cholesterol, LDL-cholesterol, HDL-cholesterol, triglyceride, glucose, leptin change in the serum, the expression of ${\beta}3AR$ and leptin gene in 3T3 cell and primary adipocyte cell, histological analysis of adipose tissue and liver tissue. GBB2 and RDT group showed that the revelation of ${\beta}3AR$ in primary adipose cell and 3T3 cell were increased considerably, and that the revelation of leptin in primary adipose cell and 3T3-L1 cell were decreased considerably. GBB2 and RDT group showed that the body weight were decreased considerably after 7-8 weeks. GBB2 and RDT group showed that the weight of adipocyte and liver were decreased. GBB2 and RDT group showed that the amount of HDL-Cholesterol were increased, the amount of glucose, LDL-Cholesterol and Triglyceride were decreased considerably. GBB2 group showed that the amount of leptin in the serum were decreased. GBB2 and RDT group showed that the size of adipocyte in adipocytes tissue and the adipose vacuoles in liver tissue were decreased. Taking all these observations into account, GBB2 considered to be effective in treating on the obese gene and obese inhibitory. Therefore we have to survey continuously in looking for the effective substance and mechanism in the future.

The Inhibitory Effects of Gambibang-3 on the Obese-Mice Induced by High-Fat Diet (감비(減肥) 3호방(號方)이 고지방식이(高脂肪食餌)로 비만이 유도된 백서(白鼠)에 미치는 영향)

  • Kim, Yong-Keol;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.4
    • /
    • pp.79-93
    • /
    • 2009
  • Objectives : In order to investigate the effects of Gambibang-3(here in after referred to GBB3) on the obese gene and obese inhibitory, C57BL/6 mice were induced by high fat diet. Methods : C57BL/6 mice were divided into four groups(normal, high fat diet with control, high fat diet with Reductil(here in after referred to RDT), high fat diet with GBB3 extract) and fed for 8 weeks. And observed that, the weight change of the adipocytes in body and liver, total cholesterol, LDL-cholesterol, HDL-cholesterol, triglyceride, glucose, leptin change in the serum, the expression of ${\beta}3AR$ and leptin gene in 3T3 cell and primary adipocyte cell. Results & conclusions : The following results were obtained in this study. 1. GBB3 and RDT group showed that the revelation of ${\beta}3AR$ in primary adipose cell and 3T3 cell were increased considerably, and that the revelation of leptin in primary adipose cell and 3T3 cell were decreased considerably. 2. GBB3 and RDT group showed that the weight of adipocyte and liver were not different with control group significantly. 3. GBB3 and RDT group showed that the amount of HDL-Cholesterol were increased considerably, the amount of glucose, LDL-Cholesterol and Triglyceride were decreased considerably. 4. GBB3 group showed that the amount of leptin in the serum were decreased considerably.