• 제목/요약/키워드: Ju-Back

검색결과 727건 처리시간 0.035초

맞대기 용접 시편의 백플레이트에 따른 피로강도 평가 (Fatigue Assessment in accordance with Back Plate of Butt Welded Specimens)

  • 도현덕;강성원;한주호;김성민;김명현
    • 대한조선학회논문집
    • /
    • 제46권1호
    • /
    • pp.24-30
    • /
    • 2009
  • The purpose of this study is to investigate the fatigue strength in accordance with back plate of butt welded specimens. Fatigue life of butt welded specimens was presented for determining the effect of back plates in terms of fatigue strength. As a results, fatigue strength of butt welded specimens with steel back plate show a decrease as compared against the butt welded specimens with ceramic back plate. Compared with the fatigue strength with respect to the existence of steel back plate, the specimens without back plate were much higher than the specimens with back plate.

유리기판 위에 성장된 카본나노튜브를 이용한 고휘도 램프 특성 (Development of flat type back-lamp using carbon nano tubes grown on glass substrate)

  • 이양두;이덕중;박정훈;유재은;이윤희;장진;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.89-92
    • /
    • 2002
  • Carbon nano tubes(CNTs) have been reported as field emission source because has a sharp tip, a high aspect tip, high chemical stability, high mechanical strength and low work function properties. In this study, we fabricated successfully the back-lamp of the I-inch flat type using CNTs, which was grown directly on cathode substrate of sodalime glass at low temperature. The brightness of CNT back-lamp is measured to $14 Kcd/m^{2}$ at $2000V_{dc}$ in spacing of $500{\mu}m$. And, the emission properties of packaged CNT back-lamp was analyzed as function of applying voltage and times.

  • PDF

동적 요부 안정화 운동 치료법이 요통 환자에 미치는 영향 (The Effect of Dynamic Lumbar Stabilization Exercise on Low Back Pain Patients)

  • 김종순;주무열;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.495-507
    • /
    • 2001
  • The purpose of this study was to find the effects of the dynamic lumbar stabilization exercise on functional recovery of low back pain patients. The subjects were consisted of sixty patients who had nonspecific subacute low back pain. All subjects randomly assigned to dynamic lumbar stabilization exercise group. Williams exercise group and modalities treatment group. The dynamic lumbar stabilization exercise group received modalities treatment with dynamic lumbar stabilization exercise. Williams exercise group received modalities treatment with Williams flexion exercise and modalities treatment group received modalities treatment without exercise. The Oswestry low back pain disability questionnaire was used to measure disability of low back pain. Assessment was carried out before treatment fur obtain baseline measurement of low back pain and reassessment were carried out at after 20 and 40 treatment sessions. The results of this study were as following: 1. The Oswestry low back pain disability questionnaire scores were significantly decreased after 20th and 40th treatment in dynamic lumber stabilization exercise group(p<.05). 2. The Oswestry low back pain disability questionnaire scores were significantly decreased after 20th and 40th treatment in Williams exercise group(p<.05). 3. The Oswestry low back pain disability questionnaire scores were significantly decreased after 20th and 40th treatment in modalities treatment group(<.05). 4. There were no statistical difference between the 3 groups at pre-treatment with Oswestry low back pain disability questionnaire scores(p>.05). 5. There were no statistical difference between the 3 groups after 20th treatment with Oswestry low back pain disability questionnaire scores(p>.05). 6. There were statistical difference between the 3 groups after 40th treatment with Oswestry low back pain disability questionnaire scores(p<.05). 7. The Oswestry low back pain disability questionnaire scores were significantly decreased after 40th treatment in all 3 groups and the decrement were greater in order of dynamic lumbar stabilization exercise group. Williams exercise group and modalities treatment group.

  • PDF

일부 요통환자를 대상으로 한 OLBPDI의 신뢰도 및 타당도 (Reliability and Validity on Oswestry Low Back Pain Disability Index(OLBPDI) in Patients with Low Back Pain)

  • 이승주;김진섭
    • 대한물리치료과학회지
    • /
    • 제18권3호
    • /
    • pp.53-61
    • /
    • 2011
  • Purpose : his study was to analyze the reliability and validity on Oswestry Low Back Pain Disability Index (OLBPDI) in patients with low back pain. Methods : The sample consisted of 211 patients who had received treatments at the physical therapy units of 3 medical institutions from February to December 2008 in Andong city. Questionnaires on the OLBPDI were recruited by 6 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient:${\alpha}$), item-discriminant validity, Pearson's relation coefficient. Results : An average of patients's age was 41.1 years. The range of OLBPDI subscales were .93~.94 in Cronbach's ${\alpha}$. The internal consistency reliability of total item-each item were also internally consistent with Cronbach's ${\alpha}$ range of .94~.95(Pearson's correlation coefficient range: .62~.89). However, high correlation were obtained among 10 items(.67~.83), therefore the item-discriminant validity was a little low. Conclusion: In conclusion, the results reported here confirm the reliability of the OLBPDI scales in patients with low back pain. The collection of information on the level of disability due to low back pain using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the reliability and validity.

  • PDF

개선된 순시 무효전력 보상기와 함께 적용된 적응 역기전력과 전류 모델 관측기 적용한 돌극형 영구자석 동기 전동기의 센서리스 제어 (Improved Instantaneous Reactive Power Compensator Applied Sensorless Control of IPMSM with Adaptive Back EMF and Current Model Observer)

  • 이준민;박순제;홍주훈;김우희;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.934-935
    • /
    • 2015
  • This paper presents the sensorless control method that employs the adaptive back-EMF(Electromotive Force) and current model observer of interior permanent magnet synchronous motor(IPMSM). The estimated back EMF considering a saliency is obtained by using the adaptive control method. The estimated EMF is inputted to the current model observer which is connected in series with adaptive back EMF estimator and is used to estimate the position and speed of the rotor. In order to improve the shortcomings of conventional method using the current error components multiplied in the compensation constant, the modified instantaneous reactive power compensator is applied. The validity of the control system presented is verified by the simulation.

  • PDF

The Effects of Spinal Decompression Therapy on Pain and Disability in Patients with Chronic Low Back Pain

  • Oh, Hyun-Ju;Jeon, Chun-Bae;Jeong, Mu-Geon;Choi, Seok-Joo
    • The Journal of Korean Physical Therapy
    • /
    • 제29권6호
    • /
    • pp.299-302
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of spinal decompression therapy on pain and disability in patients with chronic low back pain. Methods: Twenty patients with chronic low back pain were divided into an experimental group (spinal decompression therapy, n=10) and a control group (conservative physical therapy, n=10). Both groups were treated three times a week over a four-week period. Results: The comparison of between-group changes post-treatment revealed statistically significant lower levels of pain and disability in the experimental group than the control group. The comparison of within each group changes before and after the treatment showed statistically significant declines in pain and disability indexes of both groups. Conclusion: Spinal decompression therapy may be an effective intervention for improving pain and disability in patients with chronic low back pain.

Back-gate bias를 이용한 SOI nano-wire BioFET의 electrical sensing (Electrical sensing of SOI nano-wire BioFET by using back-gate bias)

  • 정명호;안창근;조원주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.354-355
    • /
    • 2008
  • The sensitivity and sensing margin of SOI(silicon on insulator) nano-wire BioFET(field effect transistor) were investigated by using back-gate bias. The channel conductance modulation was affected by doping concentration, channel length and channel width. In order to obtain high sensitivity and large sensing margin, low doping concentration, long channel and narrow width are required. We confirmed that the electrical sensing by back-gate bias is effective method for evaluation and optimization of bio-sensor.

  • PDF

후속열처리 공정을 이용한 FD Strained-SOI 1T-DRAM 소자의 동작특성 개선에 관한 연구

  • 김민수;오준석;정종완;조원주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.35-35
    • /
    • 2009
  • Capacitorless one transistor dynamic random access memory (1T-DRAM) cells were fabricated on the fully depleted strained-silicon-on-insulator (FD sSOI) and the effects of silicon back interface state on buried oxide (BOX) layer on the memory properties were evaluated. As a result, the fabricated 1T-DRAM cells showed superior electrical characteristics and a large sensing current margin (${\Delta}I_s$) between "1" state and "0" state. The back interface of SOI based capacitorless 1T-DRAM memory cell plays an important role on the memory performance. As the back interface properties were degraded by increase rapid thermal annealing (RTA) process, the performance of 1T-DRAM was also degraded. On the other hand, the properties of back interface and the performance of 1T-DRAM were considerably improved by post RTA annealing process at $450^{\circ}C$ for 30 min in a 2% $H_2/N_2$ ambient.

  • PDF