• Title/Summary/Keyword: Joule-Thomson

Search Result 49, Processing Time 0.018 seconds

Thermodynamic Analysis of Hydrogen Lquefaction Systems Using Gifford-McMahon Cryocooler

  • Chang, Ho-Myung;Park, Dae-Jong;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.39-50
    • /
    • 2000
  • Thermodynamic cycle analysis is presented to estimate the maximum liquefaction rate of hydrogen for various systems using a Gifford-McMahon(GM) cryocooler. Since the present authors` previous experiments showed that the gaseous hydrogen was liquefied approximately at the rate of 5.1 mg/s from the direct contact with a commercial two-stage GM refrigerator, this study has been proposed to predict how much the liquefaction rate can be increased in different configurations using the GM cooler and with improved heat exchangers. The optimal operating conditions have been analytically sought with real properties of normal hydrogen for the Linde-Hampson(L-H) system precooled by single-stage GM, the direct-contact system with two-stage GM, the L-H system precooled by two-stage GM, and the direct-contact system with helium GM-JT (Joule-Thomson). The maximum liquefaction rate has been predicted to be only about 7 times greater than the previous experiment, even though the highly effective heat exchangers may be employed. It is concluded that the liquefaction rate is limited mainly because of the cooling capacity of the commercially available GM cryocoolers and a practical scale of hydrogen liquefaction is possible only if the GM cooler has a greater capacity at 70-100 K.

  • PDF

Program Development for Drawing of 26 Properties and System Analysis on T-s Diagram of Water or Vapor (물의 T-s 선도 상에서 26 종류의 물성치 작도 및 시스템 해석 프로그램 개발)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.157-164
    • /
    • 2008
  • The temperature-entropy diagram of water or vapor displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. On general T-s chart of water, there are temperature, pressure, quality, specific volume, specific enthalpy, specific entropy. However, various state and process values besides above properties can be plotted on T-s diagram. In this study, we developed the software drawing twenty six kinds of properties, that is temperature, pressure, quality, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, coefficient of viscosity, kinematic coefficient of viscosity, thermal conductivity, prandtl number, ion product, static dielectric constant, isentropic exponent, velocity of sound, joule-thomson coefficient, pressure coefficient, volumetric coefficient of expansion, isentropic compressibility, and isothermal compressibility. Also, this software can analyze and print the system values of mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, and reversible work. Additionally, this software support the functions such as MS-Power Point.

  • PDF

Evaluation of Influential Factors of Hydrogen Fueling Protocol by Modeling and Simulation (모델링 및 시뮬레이션을 통한 수소충전 프로토콜 영향인자 평가)

  • CHAE, CHUNGKEUN;KANG, SUYOUN;KIM, HANNA;CHAE, SEUNGBEEN;KIM, YONGGYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.513-522
    • /
    • 2019
  • It is not easy to refuel quickly and safely with 70 MPa hydrogen. This is because the temperature in the vehicle tank rises sharply due to Joule-Thomson effect, etc. Thus protocols such as SAE J2601 in the United States and JPEC-S 0003 in Japan were established. However, they have the problem of over-complexity and lack of versatility by setting the preconditions for hot and cold cases and introducing a number of look-up tables. This study was conducted with the ultimate goal of developing new protocols based on complete real-time communication. Thermodynamic models were made and programs were developed for hydrogen refueling simulations. Simulation results confirmed that there are five parameters in the influencing factors of the hydrogen refueling protocol.

Closed-Loop Cooling System for High Field Mangets (고자기장용 자석을 위한 밀폐순환형 냉각장치)

  • Choi, Y.S.;Kim, D.L.;Lee, B.S.;Yang, H.S.;Painter, T.A.;Miller, J.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Development of the closed-loop Joule-Thomson cryoablation device for long area cooling

  • Lee, Cheonkyu;Park, Inmyong;Yoo, Donggyu;Jeong, Sangkwon;Park, Sang Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.40-48
    • /
    • 2013
  • Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 ($CHClF_2$) and R23 ($CHF_3$) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are $244.8K{\pm}2.7K$ and $239.8K{\pm}4.7K$ respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

An Analysis of the Effect of Pressure Ramp Rate on the Major Parameters of the Standard Hydrogen Fueling Protocol (수소충전 시 압력상승률이 표준충전프로토콜 중요변수에 미치는 영향 해석)

  • Chae, Chungkeun;Kim, Yonggyu;Chae, Seungbeen
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • It is not easy to fully fuel high pressure(70 MPa) hydrogen in a hydrogen vehicle tank quickly. This is because the temperature inside the tank rises rapidly due to heat caused by the Joule-Thomson effect, etc. So fueling protocols such as SAE J2601 in the U.S. and JPEC-S 0003 in Japan appeared. However, there is a problem with these protocols that a number assumption are introduced and the content is too complex and limited in scope. This study was conducted to develop a new protocol based on complete real-time communication. In this study, the hydrogen fueling simulation program were used to examine how the pressure ramp rate affects the temperature and pressure rise in the tank and the fueling flow rate. The results confirmed that the first parameter to be considered in determining the pressure ramp rate is the temperature of the tank.

Measurement of Condensation and Boiling Heat Transfer Coefficients of Non-flammable Mixed Refrigerant for Design of Cryogenic Cooling System for Semiconductor Etching Process (반도체 식각 공정용 초저온 냉각 시스템 설계를 위한 비가연성 혼합냉매 응축 및 비등 열전달 계수 측정)

  • Cheonkyu Lee;Jung-Gil Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.119-124
    • /
    • 2023
  • In this study, experimental approach of the measurement of condensation and evaporation heat transfer coefficients is discussed for mixed refrigerants using in the ultra low-temperature cooling system for semiconductor etching process. An experimental apparatus was described performing the condensation and evaporation heat transfer measurements for mixed refrigerants. The mixed refrigerant used in this study was composed of the optimal mixture determined in previous research, with a composition of Ar:R14:R23:R218 = 0.15:0.4:0.15:0.3. The experiments were conducted over a temperature range from -82℃ to 15℃ and at pressures ranging from 18.5 bar to 5 bar. The convection heat transfer coefficients of the mixed refrigerant were measured at flow rates corresponding to actual operating conditions. The condensation heat transfer coefficient ranged from approximately 0.7 to 0.9 kW/m2K, while the evaporation heat transfer coefficient ranged from 1.0 to 1.7 kW/m2K. The detailed discussion of the experimental methods, procedures, and results were described in this paper.

  • PDF