• Title/Summary/Keyword: Joint replacement

Search Result 228, Processing Time 0.033 seconds

Ceramic-Ceramic Wear Zirconia/Alumina Composites For The Application Of Total Hip Joint Implant (인공 고관절 골두용 세라믹 복합재료에 대한 세라믹-세라믹 접촉 마멸 특성 분석)

  • Kim H.;Lee K.Y.;Kim D. J.;Lee M. H.;Seo W. S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.355-361
    • /
    • 2004
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear, Alumina and zirconia (3Y-TZP) having the excellent tribological properties are coupled against acetabular cups of polyethylene and are used in clinical application worldwide. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite is very attractive due to the low temperature degradation (LTD)-free character and high fracture toughness. In the present study, we focus on the wear of ceramic on ceramic, which are able to be used as femoral heads and acetabular cups. Therefore, LTD-free zirconia/alumina composites with three compositions are made in a form of disk and cylinder, and the wear of the composites is performed on pin-on-disk type wear tester. The wear is conducted with or without lubricant. All the composites fabricated with the different composition show the good wear resistance.

  • PDF

A Study on the Performance Characteristics and Reuse Effect for Recycled Parts of CV Joint and Steering Gear Box in the Vehicles (자동차 중고재생 등속조인트와 스티어링 기어박스의 성능과 활용효과에 대한 연구)

  • 조휘창;박인송
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.199-205
    • /
    • 2002
  • The scale of repair parts market reached 0.1 billion won. Above all, it is remarkable that the automotive insurance business world is paying f3r 40 ~5o% of the whole repair cost. The repair parts consist of a genuine parts, non-genuine parts, recycling used parts. It is the recent trend that recycled parts are more popular than the genuine parts f3r repairing crashed cars due to the cost. Performance of recycled continuous velocity(CV) joints and power steering(PS) gear box as replacement parts was tested and analysed in this study. To examine the durability of the recycled parts, the replaced CV joints and PS gear box after repair were tested and analysed periodically. The results were showed that basic performance of the recycled parts was normal. However the ball cage of CV joints was more frequently damaged than genuine parts. We concluded that a test standard and amendment of related laws for recycled parts is required to get a safe and durable parts.

Complications after Total Ankle Replacement Arthroplasty (족관절 인공관절 치환술 후 발생한 합병증)

  • Lee, Kyung-Tai;Young, Ki-Won;Lee, Young-Koo;Kim, Jin-Su;Park, Shin-Yi;Kim, Do-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.128-134
    • /
    • 2008
  • Purpose: We evaluated the complications and failures after total ankle arthroplasty during at least 2 years short term follow up. Materials and Methods: There were 45 cases of 42 patients of HINTEGRA$^{{R}}$ (Newdeal SA, Lyon, France) model from November 2004 to August 2006. Follow up averaged at least 2 year. We evaluated the complications and analyzed the cause of the failures. Results: There were totally 15 cases of complication, 5 cases of medial impingement syndrome, 3 cases of varus malposition, 2 cases of delayed healing of wounds, and each one case of deep peroneal nerve problem, medial malleolus fracture, post-operative deep infection, gouty arthritis pain, and Achilles tendinitis. Conclusion: Total ankle arthroplasty had higher complication rate than any other joint arthroplasty, so we need a more meticulous preoperative and peri-operative care.

  • PDF

Outcomes of Meniscal Allograft Transplantation (동종 반월상 연골 이식술의 결과)

  • Cho, Chong-Hyuk;Choi, Yun-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Treatment options are limited for young, meniscal-deficient patients with pain. This patient population is not age appropriate for total joint replacement, but the loss of the meniscus leaves them at significant risk for the development of osteoarthritis. One increasingly popular option is the use of allograft meniscal transplantation. However, many questions still surround allograft meniscus transplantation. Furthermore, most reports in the literature on the results of meniscal transplantation describe small case series using clinical outcome measures and/or incomplete direct evaluation of the meniscus. Therefore, the results of meniscal allograft transplantation have been difficult to interpret and compare due to many confounding variables. In this study, we reviewed the current research of concerns on the results of meniscal allograft transplantation.

  • PDF

내저온열화 특성을 갖는 지르코니아/알루미나 복합세라믹의 마멸평가

  • Kim H.;Lee KY;Kim DJ;Lee MH;Seo WS
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear. Alumina and zirconia (3Y-TZP) are using in clinical application worldwide and there are many good test reports. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite having low temperature degradation-free character and high fracture tough . was developed and it leads the lower wear 3f polyethylene than alumina and zirconia. In the present study, in order to optimise the microstructure of low temperature degradation (LTD)-free zirconia/alumina composite for the best wear resistance of polyethylene, various compositions of (LTD)-free zirconia/alumina composites were fabricated, and the sliding wear of UHMWPE against these novel composites were examined and compared with that against alumina and zirconia ceramics used for total hip joint heads.

  • PDF

Effect of Surface Roughness of Counterface on Tribological Characteristics of PTFE and UHMWPE (상대재료의 표면거칠기에 따른 PTFE와 UHMWPE의 마찰 및 마멸 특성)

  • Dong, Sun;Chung, Koo-Hyun;Lee, Kyung-Sick
    • Tribology and Lubricants
    • /
    • v.27 no.6
    • /
    • pp.293-301
    • /
    • 2011
  • Understanding of the tribological characteristics of polytetrafluoroethylen (PTFE) and ultra-high-molecular-weight polyethylene (UHMWPE) is crucial for their applications such as bearing and total joint replacement. In this work, the effect of the surface roughness of carbon steel on the tribological behaviors of PTFE and UHMWPE was experimentally investigated by using block-on-ring tribotester with friction force monitoring capability. It was found that that the amount of material transfer layers of PTFE formed on the carbon steel was significantly larger than those of UHMWPE, which was responsible the lower friction coefficient of PTFE. It was also concluded that the effect of surface roughness of carbon steel on the friction coefficient of UHMWPE was more significant than that of PTFE. For UHMWPE, it was found that the effect of surface roughness of counterface was varied with respect to applied normal force and sliding as well. Based on Archard's wear law, the wear coefficient of PTFE and UHMWPE was calculated to be $3{\times}10^{-5}$ ~ $8{\times}10^{-5}$ and $7{\times}10^{-6}$ ~ $2{\times}10^{-5}$, respectively.

Deep Vein Thrombosis Prophylaxis after Total Hip Arthroplasty in Asian Patients

  • Kim, Jun-Shik
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.197-201
    • /
    • 2018
  • In Western patient populations, the reported incidence of imaging-demonstrated deep vein thrombosis (DVT) after total hip arthroplasty (THA) is as high as 70% without prophylaxis. The reported rates of symptomatic pulmonary embolism (PE) after THA in recent studies range from 0.6% to 1.5%, and the risk of fatal PE ranges from 0.11% to 0.19% in the absence of prophylaxis. Predisposing factors to DVT in western patients include advanced age, previous venous insufficiency, osteoarthritis, obesity, hyperlipidemia, dietary and genetic factors. However, Asian patients who have undergone THA have a strikingly low prevalence of DVT and virtually no postoperative PE. Some authors suggest low clinical prothrombotic risk factors and the absence of some DVT-related genetic factors in Asian patient populations decrease the risk of DVT, PE or both. In Korea, the prevalence of DVT after THA without thromboprophylaxis have ranges from 6.8% to 43.8%, and asymptomatic PE have ranges from 0% to 12.9%; there have been only two reported cases of fatal PE. Deep-wound infections resulting from postoperative hematomas or prolonged wound drainage have been reported with routine thromboprophylaxis. The prevalence of DVT differs varies based on patient ethnicity. Guidelines for the use of thromboprophylaxis were altered and focus on the potential value of outcomes compared with possible complications (e.g., bleeding).

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

Multiple Ossicular Dislocation Including Stapediovestibular Dislocation Presenting with Conductive Hearing Loss

  • Lee, Geonho;Kim, Yoonjoong;Kim, Bong Jik
    • Korean Journal of Audiology
    • /
    • v.25 no.3
    • /
    • pp.159-162
    • /
    • 2021
  • Temporal bone trauma can cause hearing loss and in case of prolonged conductive hearing loss, traumatic ossicular injury should be considered. Separation of the incudostapedial joint is the most common lesion, and stapediovestibular dislocation is relatively rare but can easily cause perilymphatic fistula. Here, we report a very rare case of external stapediovestibular dislocation after trauma, ending up with successful surgical outcome. A 27-year-old man with non-progressive hearing loss on the right side since childhood visited the clinic. Audiogram showed a conductive hearing loss with air-bone gap of 55 dB on the right side. Temporal bone CT revealed the disruption of ossicular chain. An exploratory tympanotomy identified multiple ossicular disruptions including external stapediovestibular dislocation with shiny fibrous membrane sealing the oval window. Ossicular chain reconstruction was performed using the total ossicular replacement prosthesis of titanium. A postoperative audiogram showed a recovery of air-bone gap less than 10 dB. To the best of our knowledge, this is the first case of external long-standing stapediovestibular dislocation, with oval window completely sealed with fibrous membrane, ending up with successful hearing recovery by surgery. This case would help dealing with such condition which can be encountered in the clinic.

Recalcitrant Low Back Pain Diagnosed as Hypophosphatemic Osteomalacia Induced by Antiviral Medication (항바이러스제에 의한 저인산성 골연화증으로 진단된 난치성 요통)

  • Chae, Hyun Jun;Won, Jun Hee;Lee, Won Kyung;Kim, Keewon
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.131-134
    • /
    • 2021
  • We report a rare case of anti-viral agent induced hypophosphatemic osteomalacia presented with localized and radicular pain. A 51-year-old man, who had been taking adefovir for chronic hepatitis, had experienced low back pain radiating to his right thigh for 2 years. With impression of lumbar disc herniation, he underwent magnetic resonance imaging and found multi-level disc herniation with facet joint synovial cysts. He received transforaminal epidural steroid injections, however, symptoms did not improve. To find other possible causes, additional tests were performed. Blood tests revealed hypophosphatemia and increased serum alkaline phosphatase, and osteoporosis was noted in dual-energy X-ray absorptiometry with multiple hot uptakes in bone scan. After replacement of adefovir to entecavir and supplement of phosphate and vitamin D, phosphate level and the clinical symptoms were improved. This is the first to report the presentation of osteomalacia due to anti-viral agent as radicular low back pain with facet synovial cysts.