• Title/Summary/Keyword: Joint prosthesis

Search Result 141, Processing Time 0.024 seconds

Histologic Change of Extracorporeal Irradiated Autogenous Joint Transplantation in Rabbit's Knee (가토에서 체외 방사선 조사후 재이식한 자가관절의 조직학적 변화)

  • Kim, Jae-Do;Cho, Myung-Rae;Yoo, Kyung-Sik;Kim, Young-Chang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1999
  • A new method of limb sparing by resection, extracorporeal irradiation and reimplantation has several theoretical advantages. This method preserves the mobility of a joint and avoids the problem of loosening or breakage of tumor prosthesis. This study involved using extracorporeal irradiated autogenous joint transplantation for reconstruction after en bloc resection, and observed the periods of functional union and histological changes in irradiated tissue of the knee joint. This study also aimed to clarify whether the degeneration of articular cartilage is induced in rabbits by a single 50Gy dose of irradiation at the knee joint. Twenty New Zealand rabbits about three kilograms were randomized into two groups of 10 rabbits each. In group 1, as control, we resected the knee joint followed by reimplantation without irradiation. Group 2 received extracorporeal irradiation on the resected knee joint followed by reimplantation. Following are the results of these observations. The osteotomy site showed external callus formation in the roentgenographic finding eight weeks after reimplantation. There was marked degenerative changes in the collagen fiber of the irradiated anterior cruciate ligament and meniscus during the fourth week, but new blood-vessel formation was observed in the vicinity. There was degenerative changes in the collagen fiber of articular cartilage treated extracorporeal irradiation at four and eight weeks in the scanning electron micrographic findings. These findings was in contrast to those of subchondral bone which showed decreased cellularity and empty lacuna at four and eight weeks. Autoradiography demonstrated active [$^3H$]uridine incorporation by irradiated chondrocyte at eight weeks after reimplantation. These results indicate that when destruction of the articular cartilage and soft tissue of the knee joint is not severe, extracorporeal irradiation and reimplantation can be used with several advantage in maintaining movement of the joint while avoiding problems of tumor prosthesis and rejection, and therefore extracorporeal irradiated autogenous joint transplantation can be used as a limb-sparing procedure for temporary biological spacer in the childhood bone tumor around the knee.

  • PDF

Total joint reconstruction using computer-assisted surgery with stock prostheses for a patient with bilateral TMJ ankylosis

  • Rhee, Seung-Hyun;Baek, Seung-Hak;Park, Sang-Hun;Kim, Jong-Cheol;Jeong, Chun-Gi;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.41.1-41.6
    • /
    • 2019
  • Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.

Design and Optimization of an Knee Joint of Fully-active Transfemoral Prosthesis for Stair Walking (계단 보행을 위한 능동형 대퇴의지 무릎 관절의 설계 및 최적화)

  • Ahn, Hyoung-Jong;Lee, Kwang-Hee;Hong, Yi;Lee, Chul-Hee
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2016
  • In this study, a fully active transfemoral prothesis with a knee joint is designed considering stair walking conditions. Since the torque at the knee joint required for stair walking condition is relative high compared with the one in normal walking condition, the proposed design has high torque generating mechanism. Moreover, the transfemoral prothesis is designed in compact size to reduce its weight, which is related to comfortable fit and fatigue of patients. Flat type BLDC motor is used for simple and compact structure and various components are used to generate required torque with target working angle and speed. The weight reduction of structure is carried out using optimization method after the initial design process is complete. The optimization is conducted under the load conditions of stair walking. The optimized design is validated via finite element analysis and experiments. As a result, the weight is reduced using topology and shape optimization but maintaining the safety of structure. Also the space efficiency is improved due to its compact size.

Periprosthetic Hip Joint Infection with Flavonifractor plautii: A Literature Review and Case Report

  • Alexander Wilton;Constantine Michael Glezos;Hasitha Pananwala;Han Kiong Lim
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.255-261
    • /
    • 2022
  • The purpose of this case report and review of the literature is to provide documentation on periprosthetic hip joint infection with Flavonifractor plautii (formerly known as Eubacterium plautii), a strictly anaerobic bacterium, and to report on a successful pathway for management including staged surgical revisions and extended antibiotic therapy. A systematic review of the literature was conducted, which identified this case as only the fifth documented case of human infection with this organism; as a result, conduct of further research is warranted, based on the paucity of reports in the literature addressing anaerobic periprosthetic joint infection.

Analysis of Loosening Phenomenon in Artificial Hip Joint Application Related to Design Parameters (인공고관절의 설계인자들이 해리현상에 미치는 영향에 대한 해석)

  • Kim, Young-Eun;Chung, Chung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.155-162
    • /
    • 1993
  • The human's biomechanical structure keeps an optimal state by adapting the original biomechanical structure according to a change in the physical environment. This phenomenon is believed to be the main cause of loosening of the total hip replacement which is used widely in these days. In this study the bone density change due to artificial hip joint, which is generally believed as bone-remodeling, was investigated by the finite element method. For this, 2-D FEM models with 4 nodal point elements were constructed for intact and implanted cases. The density was calculated by comparing the relative amounts of effective stress for these two cases. In this way, calculated new density values were used in the next step as input values and this procedure repeated until convergence was obtained. Severe density change was detected at the femoral cortex of the proximal-medial side as expected. Moreover, following surprising result was found from this analysis. Titanium alloy prosthesis showed less density change compared to stainless steel prosthesis at earlier stage, however, almost same amount of the density change was detected at final stage. It was also found that other design parameters could not significantly affect its density change.

  • PDF

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.

RECONSTRUCTION OF UNILATERAL TMJ ANKYLOSIS WITH METALLIC CONDYLAR PROSTHESIS;REPORT OF A CASE (금속 이식물을 이용한 악관절 강직증의 치험례)

  • Lee, Dong-Keun;Yim, Chang-Joon;Kang, Moon-Jeong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.2
    • /
    • pp.40-46
    • /
    • 1989
  • Destruction of normal temporomandibular joint architechture may produce serious functional and cosmetic deficiencies. The literature is well documented as to the etiology and pathogenesis of temporomandibular joints. Numorous surgical procedure have been advocated for temporomandibular joint ankylosis from condylectomy to arthroplasty, cartilage transplant, metallic prosthesis, interpositional implant. These were to able reconstruct the normal mandibular function, and any even procedure could obtain the satisfactory results. In this paper, we reviewed young adult patient with TMJ ankylosis and facial asymmetry who was treated with metallic condylar prosthesis and orthognathic surgery.

  • PDF

Comparison of Costochondral Graft and Customized Total Joint Reconstruction for Treatments of Temporomandibular Joint Replacement

  • Lee, Woo-Young;Park, Young-Wook;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.135-139
    • /
    • 2014
  • Purpose: We review published research on temporomandibular joint (TMJ) total replacement that compares costochondral graft and customized total joint reconstruction (especially TMJ concepts), focusing on effectiveness. Methods: We searched PubMed databases, including prospective, retrospective, case-control or longitudinal studies and significant statistical analysis. In data analysis, we divided outcomes into 'Acceptable' or 'Non-acceptable'. Results: There were seven articles found dealing with costochondral graft and 180 patients. The majority of patients had satisfactory treatment outcomes (n=109, 61%). There were six articles including 275 patients using the alloplastic material TMJ concepts. Almost all patients had satisfactory treatment outcomes (n=261, 95%). Conclusion: Comparing customized total joint reconstruction with costochondral graft, use of TMJ concepts resulted in increased quality of life and fewer complications. In conclusion, we judged that alloplastic material such as TMJ concepts is more effective device in total joint replacement than costochondral graft.

Mechanical Failure of Kotz Prosthetic Replacement for Osteosarcoma - A Case Report - (골육종에 시행한 Kotz prosthesis의 역학적 실패 - 증례 보고 -)

  • Cho, Duck-Yun;Kim, Hee-Chun;Shim, Myoun-Bo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.101-105
    • /
    • 1996
  • Prosthetic reconstruction of musculoskeletal defects about the knee for tumor has many advantages, particularly the maintenance of motion and immediate functional restoration. But, prosthetic reconstruction has inherent limitations in terms of long-term durability. The authors have reported here a patient who had mechanical failure at 61 months later following use of a modular resection system to reconstruct the segmental defect of proximal tibia in osteosarcoma. In this case, another technique of extensor mechanism reconstruction using Achilles tendon allograft was attempted. Because of the concerns involving durability of tumor prosthesis, increased emphasis has to be placed on innovation in prosthetic design.

  • PDF

Shoulder Prosthesis Mechanics (인공 견관절 역학)

  • Jeong, Jin-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.153-160
    • /
    • 2010
  • Purpose: The goal of prosthetic replacement of the shoulder is the restoration of the normal anatomy of the joint. Materials and Methods: The physician should review the variations in normal anatomy because it does vary widely and the placement of the prosthetic needs to be modified to accommodate the variations. Results and Conclusion: Several factors including anatomic, prosthetic and surgical ones can lead to the best clinical results, and these are described.