• 제목/요약/키워드: Joint performance evaluation

검색결과 338건 처리시간 0.025초

Computational methodology to determine the strength of reinforced concrete joint

  • Sasmal, Saptarshi;Vishnu Pradeesh, L.;Devi, A. Kanchana;Ramanjaneyulu, K.
    • Advances in Computational Design
    • /
    • 제1권1호
    • /
    • pp.61-77
    • /
    • 2016
  • Seismic performance of structures depends on the force flow mechanism inside the structure. Discontinuity regions, like beam-column joints, are often affected during earthquake event due to the complex and discontinuous load paths. The evaluation of shear strength and identification of failure mode of the joint region are helpful to (i) define the strength hierarchy of the beam-column sub-assemblage, (ii) quantify the influence of different parameters on the behaviour of beam-column joint and, (iii) develop suitable and adequate strengthening scheme for the joints, if required, to obtain the desired strength hierarchy. In view of this, it is very important to estimate the joint shear strength and identify the failure modes of the joint region as it is the most critical part in any beam-column sub-assemblage. One of the most effective models is softened strut and tie model which was developed by incorporating force equilibrium, strain compatibility and constitutive laws of cracked reinforced concrete. In this study, softened strut and tie model, which incorporates force equilibrium equations, compatibility conditions and material constitutive relation of the cracked concrete, are used to simulate the shear strength behaviour and to identify failure mechanisms of the beam-column joints. The observations of the present study will be helpful to arrive at the design strategy of the joints to ensure the desired failure mechanism and strength hierarchy to achieve sustainability of structural systems under seismic loading.

프리캐스트 콘크리트 계단 접합부의 접합방식에 따른 성능평가 (Performance Evaluation of the Stair Joints Constructed with Partial Precast Concrete System)

  • 장극관;이은진;진병창
    • 콘크리트학회논문집
    • /
    • 제20권6호
    • /
    • pp.833-840
    • /
    • 2008
  • 부분 프리캐스트 콘크리트 부재를 계단실에 적용할 때 현장타설이나 PC공법에 비해 시간 및 비용을 절감할 수 있다. 부분 프리캐스트 계단 부재는 각 부재의 접합방식에 따라 피난용도로 사용되는 계단실의 성능이 매우 달라질 수 있으므로 계단 접합부의 종류에 따른 성능평가를 실험적 연구를 통해 알아보고자 하였다. 현장타설되는 일체형 접합부는 계단참 끝단에 응력이 집중되어 많은 보강이 필요하고, PC공법에서 사용되는 핀접합부는 경사계단의 중앙부에 최대응력이 발생되며, 접합부의 휨성능을 무시하기 때문에 철근 배근량이 증가할 뿐만 아니라 사용성이 현저히 떨어지게 된다. 이러한 단점을 보완한 볼트형 반강접 접합부는 일체형에 가까운 내력을 보유하였으며, 연성비는 일체형에 비해 약 0.7배, 핀접합형에 비해 약 2.8배의 성능을 가져 지진하중 등의 횡하중에 대한 성능도 뛰어남을 알 수 있었다. Eurocode 접합부 분류기준에서는 semi rigid-full strength에 속하는 반강접합으로 볼 수 있고, 강성감소율 40%를 적용한 모델을 이용하여 거동을 예측할 수 있다.

브래킷형 완전강접합 모듈러 시스템의 반복가력실험과 해석적 평가 (Cyclic Loading Test and an Analytical Evaluation of the Modular System with Bracket-typed Fully Restrained Moment Connections)

  • 박재성;강창훈;손수덕;이승재
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.19-28
    • /
    • 2018
  • Key factors that ensure competitiveness of modular unit include consistent high quality and connection condition that ensures high structural performance while minimizing the overall scale of the on-site process. However, it is difficult to evaluate the structural performance of the connection of modular unit, and its structural analysis and design method can be different depending on the connection to its development, which affects the seismic performance of its final design. In particular, securing the seismic performance is the key to designing modular systems of mid-to-high-rise structure. In this paper, therefore, the seismic performance of the modular system with bracket-typed fully restrained moment connections according to stiffness and the shapes of various connection members was evaluated through experimental and analytical methods. To verify the seismic performance, a cyclic loading test of the connection joint of the proposed modular system was conducted. As a result of this study, theoretical values and experimental results were compared with the initial stiffness, hysteresis behavior and maximum bending moment of the modular system. Also, the connection joint was modeled, using the commercial program ANSYS, which was then followed by finite element analysis of the system. According to the results of the experiment, the maximum resisting force of the proposed connection exceeded the theoretical parameters, which indicated that a rigid joint structural performance could be secured. These results almost satisfied the criteria for connection bending strength of special moment frame listed on KBC2016.

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.

Evaluation of the seismic performance of butt-fusion joint in large diameter polyethylene pipelines by full-scale shaking table test

  • Jianfeng Shi;Ying Feng;Yangji Tao;Weican Guo;Riwu Yao;Jinyang Zheng
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3342-3351
    • /
    • 2023
  • High-density polyethylene (HDPE) pipelines in nuclear power plants (NPPs) have to meet high requirements for seismic performance. HDPE pipes have been proved to have good seismic performance, but joints are the weak links in the pipelines, and pipeline failures usually initiate from the defects inside the joints. Limited data are available on the seismic performance of butt-fusion joints of HDPE pipelines in NPPs, especially in terms of defects changes inside the joints after earthquakes. In this paper, full-scale shaking table tests were performed on a test section of suspended HDPE pipelines in an NPP, which included straight pipes, elbows, and 10 butt-fusion joints. During the tests, the seismic load-induced strain of the joints was analyzed by strain gauges, and it was much smaller than the internal pressure and self-weight-induced strain. Before and after the shaking table tests, phased array ultrasonic testing (PA-UT) was conducted to detect defects inside the joints. The locations, numbers, and dimensions of the defects were analyzed. It was found that defects were more likely to occur in elbows joints. No new defect was observed after the shaking table tests, and the defects showed no significant growth, indicating the satisfactory seismic performance of the butt-fusion joints.

유닛 모듈러 기둥-보 조인트의 구조 성능에 대한 실험적 평가 (An Experimental Evaluation of Structural Performance for the Beam to Column Joints in Unit Modular System)

  • 이상섭;배규웅;박금성;홍성엽
    • 한국강구조학회 논문집
    • /
    • 제25권3호
    • /
    • pp.255-265
    • /
    • 2013
  • 본 연구는 박스형 철골조 유닛 모듈러를 이용하여 고층으로 적층할 수 있는 공업화된 구조시스템을 개발하고자 하는 것이다. 이러한 목표를 달성하기 위해 효율적인 유닛 모듈러 건축시스템의 실용화를 위한 조인트의 상세 개발과 내진성능 확보기술에 대해 기본적인 실험 및 이론해석 연구가 필요하다. 본 연구에서는 고층형 유닛 모듈러 골조를 구성하는 중요 요소인 조인트의 2가지 접합 상세를 도출하였으며, 도출된 조인트에 대한 구조 성능을 실험적으로 평가하였다. 새롭게 개발된 유닛 모듈러 기둥-보 조인트에 대한 실험결과, 6.0T 기둥 및 연결구의 두께를 확보한 조인트는 강도 및 내진 성능의 확보에 있어서 조인트의 소성회전각의 유지가 가능한 것으로 나타났으며 응력이 집중되는 부근에서의 보강을 고려하면 충분히 적용 가능하리라 판단된다.

Ply-lam CLT의 합판 접합방식에 따른 휨 성능 평가 (Evaluation of Flexural Performance According to the Plywood Bonding Method of Ply-Lam CLT)

  • CHOI, Gyu Woong;YANG, Seung Min;LEE, Hyun Jae;KIM, Jun Ho;CHOI, Kwang Hyeon;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권2호
    • /
    • pp.107-121
    • /
    • 2021
  • 본 연구에서는 층재 수종과 길이방향의 합판 접합방식과 접합부의 접착제 도포 여부에 따른 휨 성능 및 파괴 양상 분석을 통하여 합판을 코어로 사용한 CLT에 적합한 합판의 접합 방식을 최적화 하고자 하였다. 더글라스 퍼 층재의 경우 길이방향 접합에 의해 휨탄성계수 약 11.5% 감소, 휨강도는 접착제 도포 및 접합방식에 따라 증가 또는 감소하였다. 접착제 미도포 butt joint, 접착제 도포 half lap joint, butt joint 조건이 최적조건으로 도출 되었다. 낙엽송 층재의 경우 길이방향 접합에 의해 휨강도는 약 15%, 휨탄성계수는 약 40% 감소하였으며 접합방식에 따른 차이를 나타내지 않았다. half lab joint와 tongue & groove joint 사용 시 합판 층의 접합부에서 휨에 파괴를 1차적으로 방지해줌으로써 중층의 층재로 전달되는 하중을 감소시켜 주는 것으로 판단된다. 본 연구 결과를 통해 Ply-lam CLT 제조과정에서 낙엽송 층재를 사용하는 경우 접합방법에 따른 차이를 나타내지 않았으며 더글라스퍼 층재를 사용할 경우 butt joint와 half lap 접합 방식이 적합할 것으로 판단된다.

보강된 이음부가 적용된 조립식 프리캐스트 콘크리트 아치의 단면 강도 평가 (Strength Evaluation on Sectional Members of Prefabricated Precast Concrete Arch with Reinforced Joint)

  • 주상훈;정철헌;배재현
    • 대한토목학회논문집
    • /
    • 제34권5호
    • /
    • pp.1363-1372
    • /
    • 2014
  • 선행연구에서 제안된 조립식 프리캐스트 콘크리트 아치의 구조성능이 실험적으로 평가되었다. 본 연구에서는 이에 대하여 재료 및 접촉 비선형을 고려한 유한요소해석을 수행하였으며, 실험결과와 비교하여 콘크리트 블록 간의 마찰계수를 결정하였다. 아치부재 단면의 강도를 평가하기 위해 탄성해석으로 단면력을 산정하여 이를 단면의 공칭강도와 비교하였다. 모든 실험체에서 평가된 최대 하중은 부재단면의 공칭강도를 상회하였으며, 실험과 유사한 결과를 보였다. 따라서 탄성해석과 단면의 극한강도모델에 의한 방법은 설계시 콘크리트 블록과 보강된 이음부로 구성된 조립식 프리캐스트 콘크리트 아치의 단면 강도를 효과적으로 평가할 수 있을 것으로 판단된다.

Development of a Tele-Rehabilitation System for Outcome Evaluation of Physical Therapy

  • Park, Hyung-Soon;Lee, Jeong-Wan
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.179-186
    • /
    • 2008
  • This paper presents a portable tele-assessment system designed for remote evaluation of the hypertonic elbow joint of neurologically impaired patients. A patient's upper limb was securely strapped to a portable limb-stretching device which is connected through Internet to a portable haptic device by which a clinician remotely moved the patient's elbow joint and felt the resistance from the patient. Elbow flexion angle and joint torques were measured from both master and slave devices and bilaterally fed back to their counterparts. In order to overcome problems associated with the network latency, two different tele-operation schemes were proposed depending on relative speed of tasks compared to the amount of time delay. For slow movement tasks, the bilateral tele-operation was achieved in real-time by designing control architectures after causality analysis. For fast movement tasks, we used a semi-real-time tele-operation scheme which provided the clinicians with stable and transparent feeling. The tele-assessment system was verified experimentally on patients with stroke. The devices were made portable and low cost, which makes it potentially more accessible to patients in remote areas.

병렬구조를 이용한 새로운 6자유도 역감제시 장치의 제어 및 평가 (Control and Evaluation of a New 6-DOF Haptic Device Using a Parallel Mechanism)

  • 윤정원;류제하
    • 제어로봇시스템학회논문지
    • /
    • 제7권2호
    • /
    • pp.160-167
    • /
    • 2001
  • This paper presents control and evaluation of a new haptic device with a 6-DOF parallel mechanism for interfacing with virtual reality. This haptic device has low inertial, high bandwidth compactness, and high output force capability mainly due to of base-fixed motors. It has also wider orientation workspace mainly due to a RRR type spherical joint. A control method is presented with gravity compensation and with force feedback by an F/T sensor to compensate for the effects of unmodeled dynamics such as friction and inertia. Also, dynamic performance has been evaluated by experiments. for force characteristics such as maximum applicable force, static-friction force, minimum controllable force, and force bandwidth Virtual wall simulation with the developed haptic device has been demonstrated.

  • PDF