• Title/Summary/Keyword: Jaw relation record

Search Result 11, Processing Time 0.009 seconds

JAW RELATION WITH PERMANENT RECORD BASES IN THE EDENTULOUS PATIENTS (총의치 환자에 있어 Permanent record base를 이용한 악간관계 기록)

  • Heo, Yun-Seok;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.231-239
    • /
    • 1995
  • When the complete denture is made, the record base for jaw relation is divided into temporary record base and permanent record base. However, The temporary record base include some disadvantages such as, the lackness of intimate contact between model and base, the lackness of retention during the jaw relation registration, When we obtained jaw relation the permanent record bases made from heat curing resin were utilized. We could get several advantages as follows : 1. The permanent record base provided intimate contact between the model and record base. 2. In fabricating occlusal rim on record base, the dimensional change of record base was little because the permanent record base was lesser influenced to thermal change of occlusal rim than the temporary record base. 3. At the stage of jaw relation, the retention of final denture could be early checked. 4. It could be able to get more accurate registration of jaw relation because all procedure were done on the same base during the jaw relation, artificial teeth arrangement, try-in, and final denture construction. 5. Although there was an inconvenience due to double curing procedure, the shrinkage rate in resin polimerization was relatively reduced so that more dimensional stability could be taken.

  • PDF

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

Gothic arch tracing to record centric relation for dentures (Gothic arch tracing을 이용한 의치의 중심위 기록)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.238-245
    • /
    • 2014
  • In order to create denture occlusion that is functional, comfortable and balanced, it is necessary to both determine a vertical dimension of occlusion that is in harmony with the patient's musculature and to record a relatively repeatable jaw relation position. This require clinical skill to establish an accurate, verifiable and reproducible vertical dimension of occlusion (VDO) and centric relation (CR). Correct vertical relation depends upon a consideration of several factors, including muscle tone, inter-dental arch space and parallelism of the ridges. Centric relation is considered to be a repeatable position from which all opening and lateral mandibular movements begin and recording this position is a critical step in the fabrication of dentures. Any errors made while taking maxillo-mandibular jaw relation records will result in denture that are uncomfortable. The purpose of this paper is to review a very simple and efficient technique for accomplishing these two important steps in denture fabrication.

Accuracy of interocclusal record established by different occlusal scans (교합스캔의 이용 방식에 따른 교합면간기록의 정확성)

  • Minjee Kang;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.142-148
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of digital mounting with occlusal scans in the interocclusal record for a full-mouth fixed prosthetic treatment condition. Materials and Methods: The entire maxillary teeth were prepared in a dentiform model and attached to an articulator in maximum intercuspation. Temporary crowns were fabricated and occlusion was adjusted. After scanning the arch with tooth preparation, digital mounting was performed using an occlusion scan of the anterior or posterior teeth areas. The accuracy of the positioned jaw relation was evaluated three-dimensionally through positional deviation and angular error of the occlusal plane. Afterwards, the same procedure was repeated on the partially edentulous model to evaluate the accuracy of digital interocclusal record. Kruskal-Wallis test and Mann-Whitney U test were used for statistical analysis, and the significance level was set at 0.05. Results: There was no significant difference in the positional error at the center of the arch in the digitally established jaw relation depending on the scan area used and remaining tooth conditions (P = 0.53). The angular error of the occlusal plane was larger when the anterior teeth were used as the overlapping area, and a smaller error value was observed when both posterior teeth were used as the overlapping area (P < 0.001). Conclusion: The use of bilateral posterior occlusal scans is recommended when digitally mounting the jaw relation established with temporary teeth during full-mouth fixed prosthetic treatment.

RELATIVE POSITION OF MANDIBULAR CONDYLE AND COMPARISON OF REPRODUCIBILITY UTILIZING DIFFERENT CENTRIC RELATION RECORD TAKING METHODS (중심위 교합채득 방법에 따른 하악과두의 상대적 위치와 재현도 비교에 관한 연구)

  • Mun, Heoung-Youp;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.945-956
    • /
    • 1994
  • In the past the jaw and occlusal relationship in centric occlusion were merely considered in case of orthodontic diagnosis and treatment planning. As the fact that functional disturbance of the temporomandibular joint may be caused by occlusal interference was recognized, the importance of functional occlusion and centric relation is emphasized today. Known the importance of centric relation, there are various opinions about definition of centric relation and its taking methods. The purpose of this study was to investigate the relative centric condyle position and to compare the reproducibility of the recordings utilizing different centric relation records obtained by different taking methods. The 15 adults with normal occlusion were participated in this study. Every four centric relation records were taken in each of three methods - leaf gauge, Dawson and myomonitor method. Then the relative centric condyle position, the distance between the condylar position in centric occlusion and the position in centric relation and the reproducibility were studied using SAM 2 articulator and mandibular position indicator. The results were as follows ; 1. The trend of condyle position was different depending on centric relation taking methods. 2. The position of condyle in centric relation by leaf gauge and Dawson methods was superior to that by myomonitor method, and the position by myomonitor method was relatively antero-inferior. 3. The distance between the condylar positions in centric occlusion and the position in centric relation was longest in myomonitor method. 4. The reproducibility had little differences in transverse direction among three methods, while leaf gauge method showed the highest reproducibility and myomonitor method did the lowest reproducibility in antero-posterior and supero-inferior direction.

  • PDF

Complete denture rehabilitation of a fully edentulous patient with unilateral facial nerve palsy: A case report (편측성 안면 신경마비 환자에서의 총의치 수복 증례)

  • Choi, Eunyoung;Lee, Ji-Hyoun;Choi, Sunyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.451-457
    • /
    • 2017
  • Bell's palsy is an acute-onset unilateral peripheral facial neuropathy. For patients with sequelae of facial paresis, the successful rehabilitation of fully edentulous arches is challenging. This case report described the treatment procedures and clinical considerations to fabricate complete dentures of a patient who showed unilateral displacement of mandible, unilateral chewing pattern and parafunctional jaw movement due to sequelae of Bell's palsy. Gothic arch tracing was used to record reproducible centric relation and lingualized occlusion was performed to provide freedom to move between centric relation and the patient's habitual functional area in fabricating satisfactory dentures in terms of function and esthetics.

Full mouth prosthodontic reconstruction on patient with occlusion collapse & decreased vertical dimension (교합 붕괴 환자의 수직고경거상을 동반한 완전 구강회복 증례)

  • Yoo, H.J.;Choi, M.H.;Kim, C.H.;Park, Y.R.;Kang, D.W.
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • One of the important things in the full mouth reconstruction is the determination of therapeutic position. Centric jaw relation is used as a therapeutic position for the full mouth reconstruction. There are several techniques associated with recording this position. Five clinically acceptable techniques are as follows: 1) Swallowing or free closure, 2) Chin point guidance, 3) Bimanual method 4) Myo-monitor technique, 5) Anterior deprogrammer. Centric relation obtained utilizing the anterior acrylic resin platform in this case. Another important thing in full mouth reconstruction is provisional restoration. Provisional restorations are an excellent diagnostic instrument, especially in full remain esthetics, phonetics, function, parafunction, and dysfunction after evaluation and acceptance through clinical trial with the provisional restorations should be accurately transferred to the final restorations to ensure the same clinical success. Especially, anterior guidance should be accurately transferred to the final restorations. An accurate anterior guidance is critical for optimal esthetics, phonetics, comfort, function, stress minimization, and longevity of teeth and restorations. To record optimum anterior guidance, customized anterior guide table is used in this case. Considering previously mentioned points, we did successive treatment. And it resulted in a better situation esthetically and functionally. Followings are what we cared in treating a patient in this case. 1) Accurate centric relation recording 2) Accurate transference of anterior guidance to the final restorations.

Fabrication of complete dentures for a patient with odontogenic myxoma: A case report (치성 점액종 환자의 총의치 수복증례)

  • Jeong, Da-Woon;Kim, Hyun-Hee;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.64-69
    • /
    • 2018
  • Odontogenic myxoma of the jaws is a rare benign odontogenic tumor. In this case, a 61-year-old male patient had a chief complaint about maxillary anterior gingival mass and excisional biopsy result confirmed odontogenic myxoma. The clear acrylic resin custom tray was designed to minimize displacement of flabby tissue which remained after the surgery. Neutral zone and external impression technique could provide satisfactory result in terms of denture stability and retention during jaw relation record and wax denture try-in procedure. This clinical report describes fabrication of complete dentures for a patient with odontogenic myxoma in regard to flabby tissue and neutral zone.

Accuracy of Bite Registration Using Intraoral Scanner Based on Data Trimming Strategy for Fremitus Teeth

  • Jeong, Yuwon;Shim, June-Sung;Kim, Jee-Hwan;Kim, Jong-Eun;Lee, Hyeonjong
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.61-67
    • /
    • 2022
  • Purpose: This study aimed to evaluate the accuracy of bite registration using intraoral scanner based on data trimming strategy for fremitus teeth. Materials and Methods: A reference model was designed by Medit Model Builder software (MEDIT Corp., Seoul). Tooth number 24 and 25 were separated as dies and tooth number 26 was prepared for full-coverage crown. Those were printed using a 3D printer (NextDent 5100). The scanning procedure was performed by a single trained operator with one intraoral scanner (i700; MEDIT Corp.). The scanning groups were divided as follows: group 1 (G1), no fremitus; group 2 (G2), 0.5 mm buccal fremitus in the maxillary left first and second premolar; and group 3 (G3), 1.5 mm buccal fremitus in the maxillary left first and second premolar. Each group was scanned 10 times and were analyzed using the reference model data. Surface-based occlusal clearance was analyzed at the prepared tooth to evaluate accuracy. Result: Mean values of control group (G1) were 1.587±0.021 mm. G2 showed similar values to those from the control group (1.580±0.024 mm before trimming strategy and 1.588±0.052 mm after trimming strategy). G3 showed significantly greater values (1.627±0.025 mm before trimming strategy and 1.590±0.024 mm after trimming strategy) and the differences were found between trimming strategy (P=0.004). Conclusion: Bite trimming strategy for fremitus teeth is a reliable technique to reduce inaccuracies caused by the mobility at maximum intercuspation.

Fabrication of mandibular suction denture for complete edentulous patient: A case report (하악 흡착식 의치를 이용한 완전 무치악 환자의 총의치 수복 증례)

  • Park, Minhyuk;Park, Sang-Won;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.257-267
    • /
    • 2020
  • The goal of suction denture is to enhance retention of dentures by the formation of negative pressure between the denture base and the underlying tissue and sealing around the denture by the mucosa. This patient has been converted to a completely edentulous state after the extraction of residual teeth. Fabrication of suction denture was planned because it was estimated that the conventional compete would be hard to achieve retention due to the absorption of residual ridge and lack of sublingual fold. Through appropriate clinical and laboratory technique such as preliminary impression on the mandibular rest position, provisional vertical dimension determination with Centric Tray® (Ivoclar Vivadent AG, Schaan, Liechtenstein), closed mouth definitive impression and jaw relation record using individual tray with Gnathometer M® (Ivoclar Vivadent AG, Schaan, Liechtenstein), artificial teeth arrangement considering stability of the denture, and proper polymerization technique that minimizes polymerization shrinkage, restoring the patient with suction denture resulted in satisfaction throughout the function and asesthetics.