• Title/Summary/Keyword: Jang-Nam(章楠)

Search Result 80, Processing Time 0.024 seconds

Design Process for Fashion Product Development Applying Taekuki (태극기를 응용한 패션상품개발을 위한 디자인 프로세스)

  • Kim Hyun-Joo;Seo Soo-Hyun;Jang Nam-Kyung
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.4 s.94
    • /
    • pp.1-15
    • /
    • 2005
  • For every country, the flag is a major symbol that represents the country. Establishing image though the use of the country's symbol is more important for achieving national competitiveness in this global age. In Korea, Taekuki has not been actively applied to fashion products, however Korean people began to realize the Taekuki as a motif of fashion with 2002 World Cup. Thus, research on fashion product development applying Taekuki is needed. This research developed designs for fashion product development applying Taekuki. In addition, through suggesting various applied motives, this research explored the product possibility of global fashion design that represents Korean identity and fashion. For research method, after research on fashion design process, design development was progressed according to the 4-phases that comprehends processes previous researchers presented. First, in the problem recognition phase, background on the introduction of Taekuki to products and Taekuki fashion during 2002 World Cup was analyzed. Then, the need and possibility of fashion product development applying Taekuki's formative characteristics were found. Second, in research and analysis phase, meaning and history of Taekuki as well as flag fashion product developments in the U.S. and England examples were reviewed. Also, individual interviews with experts and consumers were conducted to collect qualitative data regarding product and design direction. Third, in idealization for problem solving phase, 62 designs including 43 apparels and 19 accessories were emerged. Finally, in evaluation phase, 40 university students majoring design evaluated designs' creativity, function, uniqueness, symbol, aesthetics, and harmony. Through this research, it is expected that fashion products applying Taekuki will be formly established as a fashion item. Furthermore, it is also expected that product development in other categories, brand planning, and product development using other national symbols such as name, anthem, and flower will be followed.

Effect of PVP Molecular Weight on Size of Sn Nanoparticles Synthesized by Chemical Reduction (주석 나노 입자의 상온 환원 합성에서 PVP Capping Agent의 분자량에 따른 입도 변화)

  • Jang, Nam-Ie;Lee, Jong-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.27-32
    • /
    • 2011
  • Tin nanoparticles were synthesized at room temperature by a compulsive reduction reaction using tin(II) acetate and tin(II) chloride precursors. When an identical amount (0.015 g) of polyvinyl pyrrolidone (PVP) was added, it was concluded that the probability of abnormally big particles forming increased with an increase in PVP molecular weight, resulting in the wide distribution of Sn nanoparticles. Differential scanning calorimetry measurements were carried out using diethylene glycol solution containing synthesized tin nanoparticles. When the population of specific particles with sizes below 35 nm was adequate, the melting point depression peaks of tin nanoparticles corresponding to the specific size were observed besides an evaporation endothermic peak of DEG during the first heating. Because DEG was evaporated and tin nanoparticles in contact became molten and coarsened during the first heating, a melting peak of bulk tin was only observed at $232^{\circ}C$ during the second heating.

A Study on the Heavy Metal Content of Permanent Wave Products (퍼머넌트 웨이브제의 중금속 함량에 관한 연구)

  • Yoo, Tai-Soon;Jang, Nam-Soon;Jung, Yeon
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.2 no.2 s.2
    • /
    • pp.93-100
    • /
    • 2004
  • This study is to measure the heavy metal content of permanent wave products which on marketing correctly as estimating the extent of exposure by a hair permanent wave scientifically. We would like to prevent an affair from arising health obstruction as to the heavy metal who is using those and also show the basic data for proposing the new standard. The results were as follows.: in case of the average heavy metal content for a wave type thioglycol acid ingredient includes 1.61ppm(Pb), 0.03ppm(Cd), 0.05ppm(Ni), 0.27ppm(Mn), 0.82ppm(Cu) and those were recognized the significant gap between products all the heavy metals. In case of a cysteine acid ingredient includes 0.86ppm(Pb), 0.01ppm(Cd), 0.05ppm(Ni), 0.20ppm(Mn) and 0.66ppm(Cu) and those were recognized the significant gap between products except a nickel. Straight type of permanent wave reductant includes 2.11ppm(Pb), 0.01ppm(Cd), 0.27ppm(Ni), 0.66ppm(Mn), 2.53ppm(Cu) and those were recognized the significant gap between products all the heavy metals. Permanent wave reducing agent includes 1.43ppm(Pb), 0.01ppm(Cd), 0.09ppm(Ni), 0.66ppm(Mn), 0.75ppm(Cu) and those were approved the significant gap between products except a cadmium. Exposure level of the heavy metal contents per onetime permanent waving were 242.3ppm(Pb), 2.5ppm(Cd), 17.7ppm(Ni), 89.0ppm(Mn), 174.7ppm(Cu).

  • PDF

A Study on the Fabrication of Polarimetric Fiber Optic Current Sensor (편광측정법에 의한 광섬유 전류 센서 제작에 관한 연구)

  • Jang, Nam-Young;Chio, Pyung-Suk;Eun, Jae-Jeong;Park, Hae-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.33-41
    • /
    • 2004
  • In this paper, a polarimetric fiber optic current sensor(P-FOCS) is experimented and fabricated, and then a possibility to the commercial utilization of the P-FOCS is also investigated. The P-FOCS measures an applied current by a Faraday rotation linearly proportional to a magnetic field generated by the applied current. The bending-induced linear birefringence in the sensing fiber is minimized by using the low birefringent fiber. Also, all fiber-optic components are used to avoid optical losses coming from the use of bulk components. A signal processing circuit is constructed and used to eliminate the effects of intensity variations in the output signal due to losses coming from misalignments of components such as fiber connectors. Using the optical source of 632.8nm wavelength, Faraday rotation is measured by passing through the sensing fiber within the solenoid of about 1500 turns which is equivalent to a current source of about 7500A. In the range of 1000A to 7500A, the measurement error for linearity is within about 1.5%.

A study on the pressure loss coefficient of non-Newtonian fluids in the stenotic tubes (비뉴턴 유체의 협착관내 압력손실계수에 관한 연구)

  • Seo, Sang-Ho;Yu, Sang-Sin;Jang, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1603-1612
    • /
    • 1996
  • The pressure loss coefficient of Newtonian and non-Newtonian fluids such as water, aqueous solutions of Carbopol-934 and Separan AP-273 and blood in the stenotic tubes are determined experimentally and numerically. The numerical analyses for flows of non-Newtonian fluids in the stenotic tubes are conducted by the finite element method. The effect of the contraction ratio and the ratio of length to diameter on the pressure drop are investigated by the experiments and numerical analysis. The pressure loss coefficients are significantly dependent upon the Reynolds number in the laminar flow regime. As Reynolds number increases, the pressure loss coefficients of both Newtonian and non-Newtonian fluids decrease in the laminar flow regime. As the ratio of length to diameter increases the maximum pressure loss coefficient increases in the laminar flow regime for both Newtonian and non-Newtonian fluids. Newtonian fuid shows the highest values of pressure loss coefficient and blood the next, followed by Carbopol solution and Separan solution in order. Experimental results are used to verify the numerical analyses for flows of Newtonian and non-Newtonian fluids. Numerical results for the maximum pressure loss coefficient in the stenotic tubes are in fairly good agreement with the experimental results. The relative differences between the numerical and experimental results of the pressure loss coefficients in the laminar flow regime range from 0.5% to 14.8%.

Female College Students' Buying Propensity of Clothing in Regard to Their Credit Card Use - Focusing on Impulse Buying, Fashion Consciousness and Conspicuous Consumption - (여자 대학생의 신용카드 사용과 관련된 의류 구매 성향에 관한 연구 - 충동 구매 성향, 유행 추구 성향, 과시 소비 성향을 중심으로 -)

  • Chung, Woo-Young;Chung, Sung-Ji;Jang, Nam-Kyung
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.5 s.58
    • /
    • pp.819-832
    • /
    • 2005
  • The purpose of the study was to examine female college students' credit card usage characteristics and to investigate differences in buying propensity of clothing including impulse buying, consciousness, and conspicuous consumption among their buyer groups according to credit card use and personal characteristics. The questionnaires were administered to female college students in Seoul. The total of 588 questionnaires were collected and statistically analyzed by descriptive statistics, factor analysis, Analysis of Variance (ANOVA), and Duncan's test. Female college students' arrear as well as credit card use have been increasing, and they tend to purchase low price clothing item using credit card. Buying propensity was classified into three factors. There were differences in buying propensity of clothing including impulse buying, fashion consciousness, and conspicuous consumption among buyer groups according to the credit card use and personal characteristics. Students who have credit card and arrear experience, are heavy credit user, and purchase more clothing showed high impulse buying propensity. Students who purchase more clothing monthly with credit card were more fashion-conscious. Students who have credit card, are heavy credit user, and purchase more clothing showed high conspicuous consumption propensity. Implications and future research directions were discussed.

  • PDF

Surface Characteristics based on Material and Process Changes in Surface Treatment using Fast Tool Servo (FTS를 이용한 나노표면개질공정의 공정변화와 소재에 따른 표면특성)

  • Kim, Mi Ru;Lee, Deug Woo;Lee, Seung Jun;Liang, Li;Kim, Jong Man;Jang, Nam-Su
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.639-646
    • /
    • 2015
  • A treatment for improving the characteristics of a surface is very important in increasing the life of machine parts. Many studies have been carried out on the surface characteristics after such treatments. For enhanced eco-technology, an alternative to a conventional chemical surface treatment process is essential. Ultrasonic nano-crystal surface modification (UNSM) technology is a physical environmentally friendly surface treatment method. This technology was developed in domestic and currently being used. As the mechanism of UNSM technology, a ball tip attached to an ultrasonic vibration device strikes the metal surface at nearly 20,000 times per second. The resulting modified surface layer improves the surface characteristics. This paper describes a self-developed fast tool servo system applied to the UNSM process as a vibration module within a high-frequency bandwidth. After describing the surface modification process based on the material and process changes, the surface characteristics are compared.

Design and Implementation of Optical Signal Processor in Fiber-Optic Current Transducer for Electric Equipments (전력기기용 고안정성 광섬유 CT 센서의 광 신호처리기 설계 및 구현)

  • Jang, Nam-Young;Choi, Pyung-Suk;Eun, Jae-Jeong;Cheong, Hyeon-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.171-177
    • /
    • 2007
  • In this paper, we have designed and implemented an optical signal processor in order to use in a fiber-optic current CT for electric equipments where its properties were discussed. The fabricated optical signal processor is used to reduce a measurement current error that induced by the effects of intensity variation in the optical output signal due to losses coming from optical components or polarization variation in a PFOCS. Also, the optical signal processor was fabricated in compact/lightweight with unification of opto-electronic transducer part, analog signal process part, and real-time measurement part consisted of a level shift and ${\mu}-processor$. The experiment of optical signal processor has been performed in the range of $0{\sim}7,500A$ using the PFOCS made all fiber-optic components. As a result of experiment, the linearity error of measurement current is less than 1.7% and its average error is less than 0.3% in the range of $1,000A{\sim}7,000A$.

  • PDF

A Study for Complexity Improvement of Automatic Speaker Verification in PDA Environment (PDA 환경에서 자동화자 확인의 계산량 개선을 위한 연구)

  • Seo, Chang-Woo;Lim, Young-Hwan;Jeon, Sung-Chae;Jang, Nam-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.170-175
    • /
    • 2009
  • In this paper, we propose real time automatic speaker verification (ASV) system to protect personal information on personal digital assistant (PDA) device. Recently, the capacity of PDA has extended and been popular, especially for mobile environment such as mobile commerce (M-commerce). However, there still exist lots of difficulties for practical application of ASV utility to PDA device because it requires too much computational complexity. To solve this problem, we apply the method to relieve the computational burden by performing the preprocessing such as spectral subtraction and speech detection during the speech utterance. Also by applying the hidden Markov model (HMM) optimal state alignment and the sequential probability ratio test (SPRT), we can get much faster processing results. The whole system implementation is simple and compact enough to fit well with PDA device's limited memory and low CPU speed.

  • PDF

A Study on the Low-Cost Fiber-Optic Gyroscope Using the Single Mode Fiber and Depolarizer (단일모드 광섬유와 편광소멸기를 이용한 저가형 광섬유 자이로스코프에 관한 연구)

  • Jang, Nam-Young;Ham, Hyung-Jae;Song, Hui-Young;Chio, Pyung-Suk;Eun, Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.179-187
    • /
    • 2008
  • In this paper, we carried out the performance evaluation of depolarized fiber optic gyroscope(D-FOG) that was designed and fabricated with the low-cost optical communication single mode fiber and depolarizer. In order to reduce the phase error of D-FOG, the circuit of stabilized current and temperature of the light source was made and the performance was analyzed. The current and the temperature stability of the fabricated stabilization circuit were less than $200{\mu}A$ and $0.0098^{\circ}C$, respectively. Also, the D-FOG's experimental result showed that the value of the dynamic range of rotated rate, the scale factor error with a good linearity, and the zero bias drift were ${\pm}50^{\circ}/s$, 2.8881%, and $19.49^{\circ}/h$, respectively. The results indicated that a low-cost FOG was able to fabricate which was more cost effective than conventional FOG with a high-cost high-birefringent polarization maintaining fiber.

  • PDF