Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Community Composition and Functional Feeding Groups of Aquatic Insects According to Stream Order from the Gapyeong Creek in Gyeonggi-do, Korea (경기도 가평천의 하순에 따른 수서곤충 군집조성과 섭식기능군)

  • Won, Doo-Hee;Hoang, Duc-Huy;Jin, Young-Hun;Hwang, Jeong-Mi;Bae, Yeon-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.1 s.102
    • /
    • pp.21-28
    • /
    • 2003
  • Community composition and functional feeding groups of aquatic insects according to stream order were investigated from the Gapyeong Creek, a typical mid-sized Korean stream in Gyeonggi -do, Korea, in April 2000. For field investigations, the main watercourse and three major tributaries of the stream that belong to stream order ll to Vll were divided into reaches (ca. $1{\sim}4$ km in distance). Aquatic insects were sampled from one or two sites each reach (total 30 sites) using a Surber sampler ($50{\times}50$cm, mesh 0.75 mm). As a result of the quantitative samplings(two Surber samplings at riffle and pool/run per site; total $2{\times}30$=60 Surber samplings) and additional qualitative samplings, a total of 164 species of aquatic insects in 103 genera, 54 families, and 8 orders were collected from the stream. Those aquatic insects were composed of Trichoptera (56spp.: 34.1%), Ephemeroptera (43 spp.: 26.2%), Diptera (25spp.: 15.2%), Plecoptera (23 spp.: 14.0%), Coleoptera (6 spp.: 3.7%), Odonata (6 spp.:3.7%), Hemiptera (3 spp.: 1.8%), and Megaloptera (2 spp.: 1.2%); EPT-group (122 spp.:74.4%) or EPT-group plus Diptera (147 spp.: 89.6%) occupied most of the aquatic insect community; relatively larger number of species occurred in the mid-stream reaches (order III-Vl). The quantitative samplings throughout the study sites yielded a total of 26,286 individuals of aquatic insects ($136{\sim}2522$ inds./0.5 $m^2$, mean 906.4inds./0.5 $m^2$) that belongs to Ephemeroptera (11,994 inds.: 45.6%), Diptera (8730 inds.:33.2%), Trichoptera (4123 inds.: 15.7%), Plecoptera (1213 inds.: 4.6%), Coleoptera (204 inds.: 0.8%), Odonata (13 inds.: 0.05%), Megaloptera (5 inds.: 0.02%), and Hemiptera (4inds.: inds.: 0.02%); average number of individuals of aquatic insects increased as the stream order increased: average numbers of individuals of Bllecoptera and Trichoptera decreased and increased, respectively, as the stream order increased. Tolerant species such as Chironomidae spp., Uracanthella rufa and Hydropsychidae spp. were particularly abundant in the down stream reaches (order Vll) . Species diversity indices (H`) and dominance indices (Dl) were relatively higher and lower, respectively, in the mid-stream reaches (order $IV{\sim}VI$). Shredders occupied the smallest partand collector-gatherers were most abundant among the functional feeding groups(FFGs); collector-filterers considerably increased in the down stream reaches (orders Vl and VII); scrappers were relatively evenly distributed throughout the stream reaches: predators were relatively more abundant in the uppermost stream reaches(order ll) . Overall, the characteristics of aquatic insect comminity and FFGs in the Gapyeong Creek are largely similar to those in the normal streams of temperate deciduous forest in the northern hemisphere that is explained by the river confineum concept.

Clinical Efficacy of Clomiphene Citrate and Letrozole Combined with Gonadotropins for Superovulation in Patients with Clomiphene-Induced Thin Endometrium (클로미펜에 얇은 자궁내막을 보이는 환자에서 성선자극호르몬 병합 과배란유도시 클로미펜과 레트로졸의 임상적 효용성)

  • Lee, Eun-Joo;Park, Hyun-Jong;Yang, Hyo-In;Lee, Kyung-Eun;Seo, Seok-Kyo;Kim, Hye-Yeon;Cho, Si-Hyun;Choi, Young-Sik;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2009
  • Objective: The aim of this study was to compare the clinical efficacy of clomiphene citrate (CC) and letrozole combined with gonadotropins for controlled ovarian stimulation (COS) in patients with CC-induced thin endometrium Methods: Fifty-one intrauterine insemination cycles performed in patients who previously had a thin endometrium (<8 mm) to ovulation induction using CC were included in this study. A CC 100 mg/day (CC+gonadotropin group, n=26) or letrozole 2.5 or 5 mg/day (letrozole+gonadotropin group, n=25) was administered on day 3~7 of the menstrual cycle, combined with gonadotropins at dose 75~150 IU every other day starting on day 5~7. We compared total dose of gonadotropin used, endometrial thickness, endometrial pattern, number of follicles ${\geq}14\;mm$ on hCG day, pregnancy rate and multiple pregnancy rate between the two groups, which were statistically analyzed using Mann-Whitney U test or Fisher's exact test, where appropriate. Results: There were no significant differences in clinical characteristics such as age, duration of infertility, number of previous IUI cycles, basal serum hormone levels and cause of infertility between the two groups. In both groups, the endometrium was significantly thicker than that of previous ovulation induction cycles using CC. No significant differences were found in the total dose of gonadotropin used, day of hCG administration, the rate of triple endometrium and pregnancy rate. The number of follicles ${\geq}14\;mm$ was significantly lower ($3.7{\pm}1.7$ vs. $2.8{\pm}1.7$, p=0.03) and the endometrium on hCG day was significantly thicker ($7.7{\pm}1.5$ vs. $9.1{\pm}1.7$, p=0.001) in letrozole+gonadotropin group compared to CC+gonadotropin group. Conclusion: The clomiphene citrate and letrozole combined with gonadotropins appear to avoid the undesirable effects on the endometrium frequently seen with CC for ovulation induction. However, in terms of adequate endometrial development or optimal follicular growth, letrozole may be more beneficial than CC for gonadotropin-combined COS in patients with CC-induced thin endometrium. Further prospective randomized controlled studies in a larger scale will be necessary to confirm our findings.

The Effect of Spiritual Well-being on the Mental Health of the Cho-Sun Tribal Women Residing in P.R. of China (중국거주 조선족 여성의 영적 안녕정도가 정신건강에 미치는 영향)

  • Cheung, Seung-Deuk;Lee, Jong-Bum;Kim, Jin-Sung;Seo, Wan-Seok;Bai, Dai-Seg;Park, Soon-Jae;Joo, Yeol;Youm, Hyoung-Uk;Jin, Cheung-Yuan;Jin, Jiu-Miao;Ahn, Yeung-Log;Huang, Da-Hong;Biao, Mei-Zi;Zheng, Tai-Ji;Zhao, Chang-Lie
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.151-166
    • /
    • 2004
  • Background: Spirituality has been an important part of Transpersonal Psychology and is believed to have a large effect on the mental health because it has been systematized. The aim of this study was to determine the level of spiritual disposition on human beings along with its effects on one's mental health. Materials and Methods: The study targeted 400 women residing in Youn-Gil city of JiLin Prov., which is a district of the Cho-Sun tribe in China. Their spiritual well-being was studied using the Spiritual Well-being Scale-Korean Version. The spiritual well-being scale consists of 2 sub-scales of religious well-being and existential well-being. The study was evaluated using a lie scale, psychotic trend, and a combined anxiety-depression scale. The results were considered to be factors of one's mental health. The correlation between the spiritual well-being and each tendency was analyzed by regression analysis. Results: The total score of the Cho-Sun tribal women according to the spiritual well-being scale was 68.29 which was much less than the 100.65 of Korean Christian women. There was no significant correlation between the spiritual well-being and the Lie trend. However, it was found that 86%(344) of Cho-Sun tribal women scored above 70 in the Lie trend with a mean score of 74.57 which is higher than normal populations. Regarding the correlation between the spiritual well-being and psychotic trend, the psychotic trend became significantly higher when the religious well-being was at a high level. On the other hand, the psychotic trend became significantly lower when the existential well-being was at a high level. Regarding the correlation between the spiritual well-being and anxiety, the anxiety was significantly higher when the religious well-being was at a high level. However, the anxiety level was significantly low when the existential well-being was at a high level. Regarding the correlation between the spiritual well-being and depression, the depression level was somewhat significantly high when the religious well-being was at a high level. However, the depression level was significantly low when the existential well-being was at a high level. Conclusion: This study evaluated the effects of spiritual well-being on a person's mental health among Cho-Sun tribal women in Youn-Gil city of JiLIn Prov., P.R. of China. The results found that the religious well-being, which is a sub-scale of spiritual well-being, had negative effects while the existential well-being had positive effects on the mental health. These results proved that a person's religious disposition had negative effects on their mental health in a communitarian society.

  • PDF

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.