• Title/Summary/Keyword: J value

Search Result 3,183, Processing Time 0.028 seconds

Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$ ($28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성)

  • 홍현권;김규태;박세일;김구현;남두우
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.

The effects of heat treatment condition on critical characteristics of HTSC bulk (열처리조건이 초전도벌크의 임계특성에 미치는 영향)

  • 임성훈;한태희;박경국;조동언;이중근;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.356-359
    • /
    • 1997
  • The Effects of different melting temperature and holding time in the melting temperature on J$\sub$c/ of YBa$_2$Cu$_3$O$\sub$x/ based superconducting bulk using MPMG process were investigated. the value of critical current density was the largest at l120$^{\circ}C$, the melting temperature which is appointed to the mid point of (Y$_2$BaCuO$\sub$5/ + Liquid)region. With the melting temperature in which the value of J$\sub$c/ is the largest, J$\sub$c/ was again measured to see whether the holding time at this proper melting temperature has the effect on the critical characteristics. From the result above it was concluded that the melting temperature and holding time were important to improve the J$\sub$c/ and the formation of the Y$_2$BaCuO$\sub$5/. In this paper, the melting temperature obtained was l120$^{\circ}C$ and propel holding time could be obtained as 20 minute and the more holding time was not effective in the J$\sub$c/ improvement as well as the formation of Y$_2$BaCuO$\sub$5/.

  • PDF

Fabrication of $MgB_2$ tape with metal powder addition (금속분말이 첨가된 $MgB_2$ 선재의 제조 및 특성)

  • Ko, Jae-Woong;Yoo, Jai-Moo;Kim, Young-Kuk;Chung, Kook-Chae;Yoo, Sang-Im;Wang, Xio Lin;Dou, Shi Xue
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • The $MgB_2$ tapes with several metal powder addition were fabricated by PIT method with or without heat treatment. The $J_c$ value of $5.600A/cm^2$ and $16.000A/cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol % of Cu added $MgB_2$ tape without heat treatment respectively. The $J_c$ value of $8.000A/cm^2$ and $35,000A/cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol. % of Al added $MgB_2$ tape with heat treatment, respectively. The $J_c-B$ curve shows enhancement in $J_c$ under magnetic field. which suggests enhancement in workability and grain connectivity with several metal powder addition.

Effect of Reverse Cyclic Loading on the Fracture Resistance Curve of Nuclear Piping Material (역사이클하중이 원자력 배관재료의 파괴저항곡선에 미치는 영향)

  • Weon, Jong-Il;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1112-1119
    • /
    • 1999
  • Fracture resistance(J-R) curves, which are used for the elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to study the effect of reverse cyclic loading on J-R curves in CT specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio(R) and the other was the incremental plastic displacement(${\delta}_{cycle}/{\delta}_i$), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance test on CT specimens with varying load ratio and incremental plastic displacement were performed. For the SA 516 Gr. 70 steel, the results showed that the J-R curves were decreased with decreasing the load ratio and the incremental plastic displacement. When the load ratio was set to -1, the results of the J-R curves and the $J_i$ value were about $40{\sim}50$ percent of those for the monotonic loading condition. Also on condition that the incremental plastic displacement reached 1/40, the J-R curves and the $J_i$ value were about $50{\sim}60$ percent of those for the incremental plastic displacement of 1/10.

Kinetics of Anhydride Curing of Epoxy : Effect of Chain Length of Anhydride (에폭시 무수화물 경화의 동력학적 연구: 무수화물의 사슬 길이 효과)

  • Chung, I.;Lee, J.
    • Elastomers and Composites
    • /
    • v.40 no.1
    • /
    • pp.3-11
    • /
    • 2005
  • The ruling kinetics of epoxy resins with 3 different kinds or alkenylsuccinic anhydride (ASA) having C-8, C-12, and C-16 pendant side chain length with two different catalysts was studied by using differential scanning calorimetry (DSC). Nonisothermal and isoconversional method has been used for characterizing the effect of the pendant side chain length in the curing process. Results or nonisothermal method showed that there was no significant difference in the effect of the pendant side chain length of ASA. But isoconversional analysis showed that the value of the activation energy for the initiation reaction or C-8, C-12, and C-16 were $61.7{\sim}57.7kJ/mol$, $63.0{\sim}57.3 kJ/mol$, and $130.4{\sim}94.2 kJ/mol$, respectively, depending on the catalyst used. The values of activation energy for the initiation is different as reported value of 20 kJ/mol which indicating the difference in the effect of the pendant side chain length of ASA in the initial stage of the reaction.

The Added-Value Metric - A Complementary Performance Measure for Six Sigma and Lean Production

  • Setijono, Djoko;Dahlgaard, Jens J.
    • International Journal of Quality Innovation
    • /
    • v.8 no.1
    • /
    • pp.1-14
    • /
    • 2007
  • The Six Sigma and Lean Production methodologies suggest that creating value for customers is the objective of a production process or an organisation. In the production context, "added value" dominates the discussion about the creation of value to customers. However, "added value" is often only defined conceptually or discussed at a strategic level, and the link between added value and customer value has not yet been well conceptualised. Therefore, the purpose of the paper is to develop a methodology to measure added value in order to complement the existing performance measures in Six Sigma and Lean Production by conceptualising the link between customer value and added value. The conceptual link "confirms" that quality, time, and costs are the elements of added value, which are transformed into a metric to express customer value. The implementation of the metric recommends the adoption of Lean (Six) Sigma and Lean Accounting (Activity Based Costing), which thus implies that "leanness" is an important "feature" of added value.

Fabrication and superconducting property of $MgB_2$ tape with Al metal powder addition

  • Ko, Jae-Woong;Yoo, Jai-Moo;Chung, Kuk-Chae;Kim, Young-Kuk;Wang, Xiaolin;Dou, Shi Xue;Yoo, Sang-Im;Chung, Woo-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.2
    • /
    • pp.15-18
    • /
    • 2007
  • The sub micron sized spherical $MgB_2$ powders were synthesized by spray reaction method. $MgB_2$ tapes with Al addition were fabricated by Powder in Tube (PIT) method. The superconducting property and microstructure of Al doped $MgB_2$ tapes were characterized by X-ray diffraction, optical microscopy and transport measurement under magnetic field. The $J_c$ value of $MgB_2$ tapes was increased with 10 vol. % Al addition. The $J_c$ value of 5,500 A/$cm^2$ and 11,000 A/$cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol. % of Al added $MgB_2$ tape without heat treatment, respectively. The $J_c$ value of 8,000 A/$cm^2$ and 33,000 A/$cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol. % of Al added $MgB_2$ tape with heat treatment, respectively. The $J_c$-B curves show enhancement in $J_c$ (B), which suggests that the microstructure and transport properties of $MgB_2$ tapes have been improved with Al addition.

Experimental Study on the Thermal Mixing and the Critical Heat Flux in the 5${\times}$5 Rod Bundle with the Hybrid Mixing Vane (복합혼합날개를 장착한 5${\times}$5 봉다발에서 부수로 혼합 및 임계열유속 실험 연구)

  • Kang, K.H.;Shin, C.H.;Choo, Y.J.;Youn, Y.J.;Park, J.K.;Moon, S.K.;Chun, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2303-2308
    • /
    • 2007
  • Experiments were performed to determine the thermal (or turbulent) diffusion coefficient (TDC) and to investigate the critical heat flux (CHF) performance in the 5${\times}$5 rod bundle with 5 unheated rods which are supported by Hybrid Mixing Vane. In this study, HFC-134a fluid was used as working fluid and the fluid temperature were measured in the important subchannels. To determine the TDC value, the measured fluid temperatures were compared with the predicted values obtained from the MATRA code. The best optimized value of ${\beta}$ was found to be 0.02 by considering prediction statistics, i.e., average and standard deviations of the differences between the experimental results and code calculations. Using the best optimized value of ${\beta}$ as 0.02, the MATRA code predicts the test results of the fluid temperature within ${\pm}$1.0 % of error. According to the experimental results on CHF of 5 non-heating guide tubes, the case with non-heating guide tube showed a little good performance in terms of CHF.

  • PDF

Design and Estimation of a Spindle System for Centerless Grinding Machine (무심연삭기 주축계의 설계 및 성능평가)

  • Park C.H.;Hwang J.H.;Oh Y.J.;Cho S.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.86-89
    • /
    • 2005
  • Design and estimation of a spindle system which was composed of grinding spindle and regulating spindle for the centerless grinding of ferrule was performed and prototypes of each spindle were manufactured. Loop stiffness of the spindle system was 130 N/${\mu}m$. Although the value was lower than the target value of 150 N/${\mu}m$, as there included 20% of the safety factor, it was enough to machine the ferrule. Rotational accuracies of each spindle were about 0.2${\mu}m$ at the primary speed of 2,300 rpm(grinding spindle) and 300 rpm(regulating spindle). Temperature rises at the same speed were about $4.4\;\~\;4.7^{\circ}C$ in the case of grinding spindle and $1.8^{\circ}C$in the case of regulating spindle, which were well agreed with the designed value. From these results, it was estimated that the prototype of spindle system had a enough performances for the centerless grinding machine to machine the ferrule.

  • PDF

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 -)

  • Kim, Y.J.;Kim, H.J.;Seo, M.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.