• Title/Summary/Keyword: Issue Detection

Search Result 587, Processing Time 0.025 seconds

Mapping Studies on Visual Search, Eye Movement, and Eye track by Bibliometric Analysis

  • Rhie, Ye Lim;Lim, Ji Hyoun;Yun, Myung Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.377-399
    • /
    • 2015
  • Objective: The aim of this study is to understand and identify the critical issues in vision research area using content analysis and network analysis. Background: Vision, the most influential factor in information processing, has been studied in a wide range of area. As studies on vision are dispersed across a broad area of research and the number of published researches is ever increasing, a bibliometric analysis towards literature would assist researchers in understanding and identifying critical issues in their research. Method: In this study, content and network analysis were applied on the meta-data of literatures collected using three search keywords: 'visual search', 'eye movement', and 'eye tracking'. Results: Content analysis focuses on extracting meaningful information from the text, deducting seven categories of research area; 'stimuli and task', 'condition', 'measures', 'participants', 'eye movement behavior', 'biological system', and 'cognitive process'. Network analysis extracts relational aspect of research areas, presenting characteristics of sub-groups identified by community detection algorithm. Conclusion: Using these methods, studies on vision were quantitatively analyzed and the results helped understand the overall relation between concepts and keywords. Application: The results of this study suggests that the use of content and network analysis helps identifying not only trends of specific research areas but also the relational aspects of each research issue while minimizing researchers' bias. Moreover, the investigated structural relationship would help identify the interrelated subjects from a macroscopic view.

Dual-band Monopulse Receiver for Tracking Radar (추적 레이다용 Dual-band 모노펄스 수신기)

  • Yang Seong-Uk;Park Dong-Min;Na Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.767-772
    • /
    • 2006
  • The receiver of this paper is Dual-band monopulse type for prototype of tracking radar. Localization of radar technology is an issue of SamsungThales and go into development. Dual-band radar in comparison with Single-band radar requires higher cost and power consumption but there are many advantages of dealing with jamming, detection range, image signal rejection, cloud-rain influence, clutter, resolution. The receiver is comprised of X-band RF head module, Ka-band RF head module and common IF module. Each signal of X-band and Ka-band is selected by the switch in If module. Phase shifter in IF module of local stage controls the phase of sum, azimuth, elevation channel. In the test result, gain is $40{\pm}3 dB$, isolation of transmitter/receiver is 39 dBc, dynamic range is 110 dB and noise figure of each channel is 4.5dB and 6.9dB.

A Study on the Development of a Control and Monitoring System for Impressed Current Corrosion Protection (선박용 차세대 외부전원방식 제어 및 감시 시스템 UNIT 개발)

  • Kim, Y.B.;Kim, B.Y.;Suh, J.H.;Kim, J.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.104-110
    • /
    • 2006
  • Corrosion has been around for all of recorded history. Cathodic protection is the electrical solution to the corrosion problem. Corrosion is not exactly a new topic. It has been around since the beginning of time. Corrosion is simply the loss of material resulting from current leaving a metal, following through a medium, and returning to the metal at a different point. Corrosion takes many forms and has various names, such as oxidation, rust, chemical, and bacteria action. Regardless of the agent, all corrosion is the result of electrical current flow. Various methods are used to treat corrosion or to try to prevent ti. Some of these include chemical treatment. coatings, and electrical current. Especially, proper impressed current can stop corrosive action on the protected surface. In this article, we introduce the Impressed Current Cathodic Protection (ICCP) Control and monitoring system developed by ourselves. The ICCP system is composed of a power supply, anode, reference electrode and controller. The main issue is to control the current flow on the desired value such that it is possible to force a metal to be more negative(cathodic) than the natural state. From the this process, we can achieve the cathodic protection. Of course, in the developed system, the necessary functions are possessed, such as remote control, monitoring of system fault detection etc. Some experimental results show the system performance and usefulness.

  • PDF

Design of an USB Security Framework for Double Use Detection (이중사용 방지를 위한 USB 보안 프레임워크의 설계)

  • Jeong, Yoon-Su;Lee, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.93-99
    • /
    • 2011
  • Recently, the development of internet technology makes user's personal data used by being saved in USB. But there is a critical issue that personal data can be exposed with malicious purpose because that personal data doesn't need to be certificate to use. This paper proposes USB security framework to prevent a duplicate use of personal data for protecting the data which in USB. The proposed USB security framework performs certification process of user with additional 4bite of user's identification data and usage choice of USB security token before certification data when the framework uses USB security product in different network. It makes communication overhead and service delay increased. As a result of the experiment, packet certification delay time is more increased by average 7.6% in the proposed USB security framework than simple USB driver and USB Token, and procedure rate of certification server on the number of USB is also increased by average 9.8%.

Nondestructive Evaluation of Nanostructured Thin Film System Using Scanning Acoustic Microscopy (초음파현미경을 이용한 나노 구조 박막 시스템의 비파괴평가)

  • Miyasaka, Chiaki;Park, Ik-Keun;Park, Tae-Sung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.437-443
    • /
    • 2010
  • In recent years, as nano scale structured thin film technology has emerged in various fields such as the materials, biomedical and acoustic sciences, the quantitative nondestructive adhesion evaluation of thin film interfaces using ultra high frequency scanning acoustic microscopy(SAM) has become an important issue in terms of the longevity and durability of thin film devices. In this study, an effective technique for investigating the interfaces of nano scale structured thin film systems is described, based on the focusing of ultrasonic waves, the generation of leaky surface acoustic waves(LSAWs), V(z) curve simulation and ultra high frequency acoustical imaging_ Computer simulations of the V(z) curve were performed to estimate the sensitivity of detection of micro flaws(i.e., delamination) in a thin film system. Finally, experiments were conducted to confirm that a SAM system operating at a frequency of 1 GHz can be useful to visualize the micro flaws in nano structured thin film systems.

Tissue CA125 and HE4 Gene Expression Levels Offer Superior Accuracy in Discriminating Benign from Malignant Pelvic Masses

  • Fawzy, Amal;Mohamed, Mohamed R;Ali, Mohamed AM;El-Magied, Mohamed H Abd;Helal, Amany M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.323-333
    • /
    • 2016
  • Background: Ovarian cancer remains a major worldwide health care issue due to the lack of satisfactory diagnostic methods for early detection of the disease. Prior studies on the role of serum cancer antigen 125 (CA125) and human epididymis protein 4 (HE4) in detecting ovarian cancer presented conflicting results. New tools to improve the accuracy of identifying malignancy are urgently needed. We here aimed to evaluate the diagnostic utility of tissue CA125 and HE4 gene expression in comparison to serum CA125 and HE4 in discriminating benign from malignant pelvic masses. Materials and Methods: One-hundred Egyptian women were enrolled in this study, including 60 epithelial ovarian cancer (EOC) patients and 20 benign ovarian tumor patients, as well as 20 apparently healthy women. Preoperative serum levels of CA125 and HE4 were measured by immunoassays. Tissue expression levels of genes encoding CA125 and HE4 were determined by quantitative real time polymerase chain reaction (qRT-PCR). The diagnostic performance of CA125 and HE4, measured either as mRNA or protein levels, was evaluated by receiver operating characteristic (ROC) curves. Results: The serum CA125+HE4 combination and serum HE4, with area under the curve (AUC) values of 0.935 and 0.932, respectively, performed significantly better than serum CA125 (AUC=0.592; P<0.001). Tissue CA125 and HE4 (AUC=1) performed significantly better than serum CA125 (P<0.001), serum HE4 (P=0.016) and the serum CA125+HE4 combination (P=0.018). Conclusions: Measurement of tissue CA125 and HE4 gene expression not only improves discriminatory performance, but also broadens the range of differential diagnostic possibilities in distinguishing EOC from benign ovarian tumors.

Economic Evaluation of Prostate Cancer Screening Test as a National Cancer Screening Program in South Korea

  • Shin, Sangjin;Kim, Youn Hee;Hwang, Jin Sub;Lee, Yoon Jae;Lee, Sang Moo;Ahn, Jeonghoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3383-3389
    • /
    • 2014
  • Background: Prostate cancer is rapidly increasing in Korea and professional societies have requested adding prostate specific antigen (PSA) testing to the National Cancer Screening Program (NCSP), but this started a controversy in Korea and neutral evidence on this issue is required more than ever. The purpose of this study was to provide economic evidence to the decision makers of the NCSP. Materials and Methods: A cost-utility analysis was performed on the adoption of PSA screening program among men aged 50-74-years in Korea from the healthcare system perspective. Several data sources were used for the cost-utility analysis, including general health screening data, the Korea Central Cancer Registry, national insurance claims data, and cause of mortality from the National Statistical Office. To solicit the utility index of prostate cancer, a face-to-face interview for typical men aged 40 to 69 was conducted using a Time-Trade Off method. Results: As a result, the increase of effectiveness was estimated to be very low, when adopting PSA screening, and the incremental cost effectiveness ratio (ICER) was analyzed as about 94 million KRW. Sensitivity analyses were performed on the incidence rate, screening rate, cancer stage distribution, utility index, and treatment costs but the results were consistent with the base analysis. Conclusions: Under Korean circumstances with a relatively low incidence rate of prostate cancer, PSA screening is not cost-effective. Therefore, we conclude that adopting national prostate cancer screening would not be beneficial until further evidence is provided in the future.

Comparison of Cervical Cell Morphology Using Two Different Cytology Techniques for Early Detection of Pre-Cancerous Lesions

  • Moosa, Najla Yussuf;Khattak, Nuzhat;Alam, Muhammad Irfan;Sher, Alam;Shah, Walayat;Mobashar, Shumaila;Alam, Muhammad Imran;Javid, Asima
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.975-981
    • /
    • 2014
  • Cervical cancer is an issue of foremost importance globally, specifically affecting the developing nations. Significant advances have taken place with regard to diagnosis of cervical cancer, especially with screening. Appropriate screening measures can thus reduce the incidence of cervical cancer. The most desirable screening technique should be less invasive, easy to perform, cost-effective and cover a wide range of diagnostic icons. Manual liquid based cytology (MLBC) can be considered as one of the suitable technique for screening with the above-mentioned benefits. The aim of the current study was to compare two cervical screening techniques on the basis of different morphological parameters and staining parameters by using modified acetic acid Pap staining to see the possibility of reducing time economy involved in conventional Pap staining (CPS). The study was conducted on a total 88 cases and all were analyzed with both MLBC and CPS. Forty eight cases that were regarded as satisfactory on the basis of Bethesda system by both methods were further recruited for investigation. Their morphological parameters and staining quality were compared and scored according to a scoring system defined in the study. Quality indices was calculated for both staining procedures and smear techniques.

Novel Approach of a Phage-Based Magnetoelastic Biosensor for the Detection of Salmonella enterica serovar Typhimurium in Soil

  • Park, Mi-Kyung;Chin, Bryan A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2051-2059
    • /
    • 2016
  • To date, there has been no employment of a magnetoelastic (ME) biosensor method to detect Salmonella enterica serovar Typhimurium in soil. The ME biosensor method needs to be investigated and modified for its successful performance. The filtration method, cation-exchange resin method, and combinations of both methods were employed for the extraction of S. Typhimurium from soil. The number of S. Typhimurium and the resonant frequency shift of the ME sensor were then compared using a brilliant green sulfa agar plate and an HP 8751A network analyzer. A blocking study was performed using bovine serum albumin (BSA), polyethylene glycol (PEG), and casein powder suspension. Finally, the modified ME biosensor method was performed to detect S. Typhimurium in soil. The number of S. Typhimurium was significantly decreased from 7.10 log CFU/soil to 4.45-4.72 log CFU/soil after introduction of the cation-exchange resin method. The greatest resonant frequency shift of the measurement sensor was found when employing centrifugation and filtration procedures. The resonant frequency shift of the PEG-blocked measurement sensor was $3,219{\pm}755Hz$, which was significantly greater than those of the BSA- and casein-blocked ME sensor. The optimum concentration of PEG was determined to be 1.0 mg/ml after considering the resonant shift and economic issue. Finally, the modified ME biosensor method was able to detect S. Typhimurium in soil in a dose-response manner. Although these modifications of the ME biosensor method sacrificed some advantages, such as cost, time effectiveness, and operator friendliness, this study demonstrated a novel approach of the ME biosensor method to detect S. Typhimurium in soil.

Remote Sensing-assisted Disaster Monitoring and Risk Analysis (원격탐사를 활용한 연속적 재난상황 인지 및 위험 모니터링 기술)

  • Im, Jungho;Sohn, Hong-Gyoo;Kim, Duk-jin;Choi, Jinmu
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1007-1011
    • /
    • 2020
  • Recently, natural and anthropogenic disasters have rapidly increased due to the on-going climate change and various human activities. Remote sensing (RS) technology enables the continuous monitoring and rapid detection of disastrous events thanks to its advantages covering vast areas at high temporal resolution. Moreover, RS technology has been very actively used in disaster monitoring and assessment since cluster- and micro-satellites and drones were introduced and became popular. In this special issue, nine papers were introduced, including the processing and applications of remote sensing data for monitoring, assessment, and prediction of various natural disasters. These papers are expected to serve as useful references for disaster management in the future.