• Title/Summary/Keyword: Isotope

Search Result 1,511, Processing Time 0.025 seconds

Study in vivo metabolism using nuclear medical examination of the dose rate reduction (체내대사를 이용한 핵의학적 검사의 선량률 저감에 관한 연구)

  • Kang, Yong-Gil;Na, Soo-Kyung;Hong, Jin-Woong;Lee, Gui-Won;Kim, Nak-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • The purpose of this study was administered to the body for examination and treatment, high-energy radioactive isotope(F-18, I-131) in vitro discharge experiments. Increasing exposed dose of radiation to health professionals is caused by the increase of PET/CT use and a radioactive isotope. Therefore, the high-energy isotope F-18 and I-131 after administration about using Metabolite excretion was studied. As a results of this study, patients had plenty of fluids for testing and treatment alone administered radiopharmaceuticals can be more than twice as fast excretion induced emissions. Also was able to get a better image space to reduce the dose rate.

  • PDF

Development of an Isotope-Dilution Flow-Injection Electrospray/ Mass Spectrometric Method for the Accurate Determination of Glucosamine in Pharmaceutical Formulation

  • Kim, Gui-Nam;Kim, Byung-Joo;Ahn, Seong-Hee;Hwang, Eui-Jin;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.363-367
    • /
    • 2009
  • An isotope-dilution flow-injection electrospray/mass spectrometric method was developed for the accurate determination of glucosamine contents in pharmaceutical formulations. Samples were extracted by methanol. After spiking glucosamine-1-$^{13}C_1$ as an internal standard, the extracts were then analyzed by flow-injection ESI/MS in a selected ion monitoring (SIM) mode to detect [M+H]$^+$ ions of the analyte and its isotope analogue at m/z 180 and m/z 181, respectively. Confirmatory measurements were made by selectively monitoring the collisionally induced dissociation channels of m/z 180 $\rightarrow$ m/z 72 and m/z 181 $\rightarrow$73, respectively, to test the possibility of bias in the SIM method due to matrix interferences, but any significant bias in the SIM mode was not observed. Repeatability and reproducibility studies showed that the flow-injection ESI/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0 %. Other results for the method validation are reported.

Kinetics and Mechanism of Michael-type Reactions of Ethyl Propiolate with Alicyclic Secondary Amines in H2O and MeCN: Solvent Effect on Reactivity and Transition-State Structure

  • Kim, Song-I;Baek, Hye-Won;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2909-2912
    • /
    • 2009
  • The amines studied in this study are less reactive toward ethyl propiolate (3) in MeCN than in H$_2$O although they are 7 to 9 pK$_a$ units more basic in the aprotic solvent. The reactivity of morpholine and deuterated morpholine toward 3 is found to be identical, indicating that proton transfer occurs after rate-determining step (RDS). The fact that kinetic isotope effect is absent excludes a stepwise mechanism in which proton transfer occurs in RDS as well as a concerted mechanism in which nucleophilic attack and proton transfer occur concertedly through a 4-membered cyclic transition state (TS). Thus, the reactions have been concluded to proceed through a stepwise mechanism in which proton transfer occurs after RDS. Brønsted-type plots are linear with small ${\beta}_{nuc}$ values, i.e., ${\beta}_{nuc}$ = 0.29 in H$_2$O and ${\beta}_{nuc}$ = 0.51 in MeCN, indicating that bond formation is not advanced significantly in RDS. The small ${\beta}_{nuc}$ value also supports the conclusion drawn from the study of kinetic isotope effect.

Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

  • Shin, Hyun-Ju;Kim, Byung-Joo;Lee, Joon-Hee;Hwang, Eui-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3663-3667
    • /
    • 2010
  • Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-$^{13}C_2$, $^{15}N$-acetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z $152{\rightarrow}110$ and m/z $155{\rightarrow}111$ for acetaminophen and acetyl-$^{13}C_2$, $^{15}N$-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

Flow Analysis for Fission Moly Target Cooling in HANARO (하나로 Fission Moly 표적 냉각에 대한 유동해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.502-507
    • /
    • 2003
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is under normal operation since it reached the initial critical in February 1995. The HANARO is used for fuel performance tests, radio isotope productions, reactor material performance tests, silicone semiconductor productions and etc. Specially, the HANARO is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and is under developing a target handling tool for loading and unloading those at a flow tube (OR-5). The target should be sufficiently cooled in the flow tube without an interference with the cooling of the others and an induction of extremely vibration. This topic is described an analectic analysis for the cooling characteristics of the fission moly-99 target to find the minimum cooling water. It was confirmed through the analysis results that the minimum cooling water, about 2.717 kg/s flew through the flow tube under the worst case that the guide tube got no perforating holes for cooling water to pass through the holes and that the target was safely cooled under about seventy percent (70%) of the maximum allowable temperature of the target.

  • PDF

Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석)

  • Suh, Jungkee;Woo, Jinchoon;Min, Hyungsik;Yim, Myeongcheul
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR THE DETERMINATION OF 237Np IN SPENT NUCLEAR FUEL SAMPLES BY ISOTOPE DILUTION METHOD USING 239Np AS A SPIKE

  • Joe, Kihsoo;Han, Sun-Ho;Song, Byung-Chul;Lee, Chang-Heon;Ha, Yeong-Keong;Song, Kyuseok
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.415-420
    • /
    • 2013
  • A determination method for $^{237}Np$ in spent nuclear fuel samples was developed using an isotope dilution method with $^{239}Np$ as a spike. In this method, inductively coupled plasma mass spectrometry (ICP-MS) was taken for the $^{237}Np$ instead of the previously used alpha spectrometry. $^{237}Np$ and $^{239}Np$ were measured by ICP-MS and gamma spectrometry, respectively. The recovery yield of $^{237}Np$ in synthetic samples was $95.9{\pm}9.7$% (1S, n=4). The $^{237}Np$ contents in the spent fuel samples were 0.15, 0.25, and $1.06{\mu}g/mgU$ and these values were compared with those from ORIGEN-2 code. A fairly good agreement between the measurements (m) and calculations (c) was obtained, giving ratios (m/c) of 0.93, 1.12 and 1.25 for the three PWR spent fuel samples with burnups of 16.7, 19.0, and 55.9 GWd/MtU, respectively.

Simulation Study of a High Current Proton Beam Transport for a 70MeV Cyclotron Injection

  • Choi, Y.K.;Kim, Y.S.;Hong, S.K.;Kim, J.H.;Kim, J.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.183.1-183.1
    • /
    • 2013
  • 70 MeV 사이클로트론의 인젝션 빔 라인은 Multi-CUSP 이온원에서 인출된 H- 빔을 펄스 또는 번칭하여 인플렉터를 통해 사이클로트론의 가속영역인 Dee로 전송하는 역할을 한다. 이 때, 빔을 번칭 시킴으로써 가속효율을 높이고, 손실을 줄여 높은 전류의 빔을 공급할 수 있도록 해야한다. 인젝션 시스템은 einzel lens, chopper, buncher, solenoid 등으로 구성된다. Einzel lens는 빔을 buncher의 중심으로 집속시켜 buncher의 번칭 효율을 높이고, buncher는 전기장을 이용하여 빔을 진행방향으로 집속시키는 기능을 갖는다. Chopper는 번칭된 빔을 일정 주기로 편향을 시켜 펄스 빔의 형태로 전송하는 역할을 한다. 솔레노이드는 적절한 자기장을 이용하여 빔을 집속시켜 인플렉터로 전송한다. 본 연구에서는 사이클로트론의 고전류 인젝션 시스템을 구축하고 각각의 구성요소에서 빔 envelope를 계산하고 비교하였다. SIMION code는 user가 지정한 특성을 가진 개별 입자의 궤도를 추적하는 프로그램으로 인젝션 시스템을 구성하는 각각의 컴포넌트에서의 입자의 진행모습과 buncher를 이용하여 빔의 전송 밀도가 향상됨을 확인하였다. 아울러 TRANSPORT 및 TURTLE 프로그램을 이용하여 SIMION을 통해 계산된 빔의 envelope과 비교하였다.

  • PDF

ANALYSIS OF HIGH BURNUP PRESSURIZED WATER REACTOR FUEL USING URANIUM, PLUTONIUM, NEODYMIUM, AND CESIUM ISOTOPE CORRELATIONS WITH BURNUP

  • KIM, JUNG SUK;JEON, YOUNG SHIN;PARK, SOON DAL;HA, YEONG-KEONG;SONG, KYUSEOK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.924-933
    • /
    • 2015
  • The correlation of the isotopic composition of uranium, plutonium, neodymium, and cesium with the burnup for high burnup pressurized water reactor fuels irradiated in nuclear power reactors has been experimentally investigated. The total burnup was determined by Nd-148 and the fractional $^{235}U$ burnup was determined by U and Pu mass spectrometric methods. The isotopic compositions of U, Pu, Nd, and Cs after their separation from the irradiated fuel samples were measured using thermal ionization mass spectrometry. The contents of these elements in the irradiated fuel were determined through an isotope dilution mass spectrometric method using $^{233}U$, $^{242}Pu$, $^{150}Nd$, and $^{133}Cs$ as spikes. The activity ratios of Cs isotopes in the fuel samples were determined using gamma-ray spectrometry. The content of each element and its isotopic compositions in the irradiated fuel were expressed by their correlation with the total and fractional burnup, burnup parameters, and the isotopic compositions of different elements. The results obtained from the experimental methods were compared with those calculated using the ORIGEN-S code.

Recent shell midden studies in Korea (우리나라 패총 연구의 최근 동향)

  • Deog-im, An
    • Korean Journal of Heritage: History & Science
    • /
    • v.39
    • /
    • pp.39-58
    • /
    • 2006
  • This study reviews recent shell midden studies in Korea. With more interest in biological materials, recent shell midden studies have attempted to reconstruct palaeoenvironment, and understand subsistence economy, the formation processes and function of sites and past culture. Especially, one of the major topics in prehistoric Korean shell midden studies is the transitional process from hunter-gatherer to farmer. To solve these questions related with shell middens, new sampling strategies and excavation techniques have been adopted. Analytical methods combined with scientifical technologies also have been introduced to shell middle studies. These methods indude stable isotope analyses(Oxygen isotope and Carbon and Nitrogen isotope analyses) and growth-line analysis, etc.