• 제목/요약/키워드: Isolator Mass

검색결과 38건 처리시간 0.023초

The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.425-434
    • /
    • 2019
  • The most effective passive vibration control and seismic resistance options in a reinforced concrete (RC) high-rise building (HRB) are the base isolation and the tuned mass damper (TMD) system. Many options, which may be suitable or not for different soil types, with different types of bearing systems, like rubber isolator, friction pendulum isolator and tension/compression isolator, are investigated to resist the base straining actions under five different earthquakes. TMD resists the seismic response, as a control system, by reducing top displacement or the total movement of the structure. Base isolation and TMDs work under seismic load in a different way, so the combination between base isolation and TMDs will reduce the harmful effect of the earthquakes in an effective and systematic way. In this paper, a comprehensive study of the combination of TMDs with three different base-isolator types for three different soil types and under five different earthquakes is conducted. The seismic response results under five different earthquakes of the studied nine RC HRB models (depicted by the top displacement, base shear force and base bending moment) are compared to show the most suitable hybrid passive vibration control system for three different soil types.

Seismic performance of a building base-isolated by TFP susceptible to pound with a surrounding moat wall

  • Movahhed, Ataallah Sadeghi;Zardari, Saeid;Sadoglu, Erol
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.87-100
    • /
    • 2022
  • Limiting the displacement of seismic isolators causes a pounding phenomenon under severe earthquakes. Therefore, the ASCE 7-16 has provided minimum criteria for the design of the isolated building. In this research the seismic response of isolated buildings by Triple Friction Pendulum Isolator (TFPI) under the impact, expected, and unexpected mass eccentricity was evaluated. Also, the effect of different design parameters on the seismic behavior of structural and nonstructural elements was found. For this, a special steel moment frame structure with a surrounding moat wall was designed according to the criteria, by considering different response modification coefficients (RI), and 20% mass eccentricity in one direction. Then, different values of these parameters and the damping of the base isolation were evaluated. The results show that the structural elements have acceptable behavior after impact, but the nonstructural components are placed in a moderate damage range after impact and the used improved methods could not ameliorate the level of damage. The reduction in the RI and the enhancement of the isolator's damping are beneficial up to a certain point for improving the seismic response after impact. The moat wall reduces torque and maximum absolute acceleration (MAA) due to unexpected enhancement of mass eccentricity. However, drifts of some stories increase. Also, the difference between the response of story drift by expected and unexpected mass eccentricity is less. This indicates that the minimum requirement displacement according to ASCE 7-16 criteria lead to acceptable results under the unexpected enhancement of mass eccentricity.

수치 해법을 이용하여 제진대에 부착된 가속도 센서의 진동 측정 (Using Numerical Solutions of the Vibration Measurement Accelerometers attached Vibration Isolator)

  • 신동호;이정우;이종원;오재응;이정윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.875-880
    • /
    • 2012
  • According to the fixation detailed drawing and lightweight anger tendency of the product the vibration control of precision equipments is essential and establishes under the equipments. so It is important to know vibration characteristics of vibration isolator. For this reason the accelerometer attaches in vibration isolator and measures an acceleration response. The acceleration response which is measured will lead double integral and will be able to predict a displacement of vibration isolator. However, in compliance with the effect of the accelerometer can not be accurately. From this paper, mass, damping ratio and natural frequency of the accelerometers by changing the vibration isolator to predict the acceleration response and the results were compared.

  • PDF

Seismic responses of asymmetric steel structures isolated with the TCFP subjected to mathematical near-fault pulse models

  • Tajammolian, H.;Khoshnoudian, F.;Bokaeian, V.
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.931-953
    • /
    • 2016
  • In this paper, the effects of mass eccentricity of superstructure as well as stiffness eccentricity of isolators on the amplification of seismic responses of base-isolated structures are investigated by using mathematical near-fault pulse models. Superstructures with 3, 6 and 9 stories and aspect ratios equal to 1, 2 and 3 are mounted on a reasonable variety of Triple Concave Friction Pendulum (TCFP) bearings considering different period and damping ratio. Three-dimensional linear superstructure mounted on nonlinear isolators are subjected to simplified pulses including fling step and forward directivity while various pulse period ($T_p$) and Peak Ground Velocity (PGV) amounts as two crucial parameters of these pulses are scrutinized. Maximum isolator displacement and base shear as well as peak superstructure acceleration and drift are selected as the main engineering demand parameters. The results indicate that the torsional intensification of different demand parameters caused by superstructure mass eccentricity is more significant than isolator stiffness eccentricity. The torsion due to mass eccentricity has intensified the base shear of asymmetric 6-story model 2.55 times comparing to symmetric one. In similar circumstances, the isolator displacement and roof acceleration are increased 49 and 116 percent respectively in the presence of mass eccentricity. Furthermore, it is demonstrated that torsional effects of mass eccentricity can force the drift to reach the allowable limit of ASCE 7 standard in the presence of forward directivity pulses.

수치 해석을 이용하여 제진대와 제진대에 부착된 가속도계의 가속도 비교 (Comparison of Acceleration of Vibration Isolator and Accelerometer Attached Vibration Isolator Using Numerical Analysis)

  • 신동호;이정우;오재응;이정윤
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.17-24
    • /
    • 2013
  • The process of producing high precision and light weight product is always exposed to impact load or shock. Because of this, isolator device is required. To measure the response of the isolator, accelerometer is practically used. However, the measured response of the accelerometer is different to the response of the isolator. To predict the response of the accelerometer and the isolator, 2-DOF damped system with an input shock is modeled using numerical analysis. 1-DOF damped system with a base excitation is also used to predict the response of the isolator. The mass ratio, damping ratio, and natural frequency ratio are then varied. The predicted responses from the two modeling approaches are compared and large errors are found.

설계 파라미터를 고려한 HSLDS 마그네틱 진동절연체의 실험적 성능평가 (Experimental Evaluation of the Performance of the HSLDS Magnetic Vibration Isolator with Consideration of the Design Parameter)

  • 신기홍
    • 한국소음진동공학회논문집
    • /
    • 제21권4호
    • /
    • pp.352-356
    • /
    • 2011
  • The isolation performance of a linear vibration isolator is limited to the ratio of stiffness to mass it supports. The stiffness of the isolator must be large enough to hold the weight. This results in the deterioration of the isolation performance. Recently, to overcome this fundamental limitation, the HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was introduced and its isolation characteristic was investigated theoretically. In this paper, the isolation performance of the HSLDS magnetic isolator is examined experimentally. Considerable amount of experiments are performed by carefully considering nonlinear characteristics. The experimental results verify the practical usability promisingly and agree with the theoretical studies, i.e. its performance is largely dependent on the key design parameter.

면진된 전단 거동 구조물의 층응답스펙트럼에 대한 편심효과 (In-Structure Response Spectra of Seismically Isolated Shear Buildings Considering Eccentricity Effect)

  • 이승재;김정한
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2024
  • For important structures such as nuclear power plants, In-Structure Response Spectrum (ISRS) analysis is essential because it evaluates the safety of equipment and components installed in the structure. Because most structures are asymmetric, the response can be affected by eccentricity. In the case of seismically isolated structures, this effect can be greater due to the difference between the center of mass of the structure and the center of rigidity of the isolator layer. Therefore, eccentricity effects must be considered when designing or evaluating the ISRS of seismically isolated structures. This study investigated the change of the ISRS of an isolated structure by assuming accidental eccentricity. The variables that affect the ISRS of the isolated structure were analyzed to see what additional impact they had due to eccentricity. The ISRS of the seismically isolated structure with eccentricity was amplified more than when there was non-eccentricity, and it was boosted more significantly in specific period ranges depending on the isolator's initial stiffness and seismic intensity. Finally, whether the displacement requirement of isolators can be applied to the variation of the ISRS due to eccentricity in the design code was also examined.

Vibration isolation with smart fluid dampers: a benchmarking study

  • Batterbee, D.C.;Sims, N.D.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.235-256
    • /
    • 2005
  • The non-linear behaviour of electrorheological (ER) and magnetorheological (MR) dampers makes it difficult to design effective control strategies, and as a consequence a wide range of control systems have been proposed in the literature. These previous studies have not always compared the performance to equivalent passive systems, alternative control designs, or idealised active systems. As a result it is often impossible to compare the performance of different smart damper control strategies. This article provides some insight into the relative performance of two MR damper control strategies: on/off control and feedback linearisation. The performance of both strategies is benchmarked against ideal passive, semi-active and fully active damping. The study relies upon a previously developed model of an MR damper, which in this work is validated experimentally under closed-loop conditions with a broadband mechanical excitation. Two vibration isolation case studies are investigated: a single-degree-of-freedom mass-isolator, and a two-degree-of-freedom system that represents a vehicle suspension system. In both cases, a variety of broadband mechanical excitations are used and the results analysed in the frequency domain. It is shown that although on/off control is more straightforward to implement, its performance is worse than the feedback linearisation strategy, and can be extremely sensitive to the excitation conditions.

Effects of ground motion frequency content on performance of isolated bridges with SSI

  • Neethu, B;Das, Diptesh;Garia, Siddharth
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.353-363
    • /
    • 2017
  • The present study considers a multi-span continuous bridge, isolated by lead rubber bearing (LRB). Dynamic soilstructure interaction (SSI) is modelled with the help of a simplified, sway-rocking model for different types of soil. It is well understood from the literature that SSI influences the structural responses and the isolator performance. However, the abovementioned effect of SSI also depends on the earthquake ground motion properties. It is very important to understand how the interaction between soil and structure varies with the earthquake ground motion characteristics but, as far as the knowledge of the authors go, no study has been carried out to investigate this effect. Therefore, the objectives of the present study are to investigate the influence of earthquake ground motion characteristics on: (a) the responses of a multi span bridge (isolated and non-isolated), (b) the performance of the isolator and, most importantly, (c) the soil-structure interaction. Statistical analyses are conducted by considering 14 earthquakes which are selected in such a way that they can be categorized into three frequency content groups according to their peak ground acceleration to peak ground velocity (PGA/PGV) ratio. Lumped mass model of the bridge is developed and time history analyses are carried out by solving the governing equations of motion in the state space form. The performance of the isolator is studied by comparing the responses of the bridge with those of the corresponding uncontrolled bridge (i.e., non-isolated bridge). On studying the effect of earthquake motions, it is observed that the earthquake ground motion characteristics affect the interaction between soil and structure in such a way that the responses decrease with increase in frequency content of the earthquake for all the types of soil considered. The reverse phenomenon is observed in case of the isolator performance where the control efficiencies increase with frequency content of earthquake.

고감쇠 면진베어링에 의해 지지된 면진구조물의 지진응답해석 (Seismic Response Analysis of a Base-Isolated Structure Supported on High Damping Rubber Bearings)

  • 유봉;이재한;구경회
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.99-106
    • /
    • 1995
  • The seismic responses of a base Isolated Pressurized Water Reactor(PWR) are investigated using a mathematical model which expresses the superstructure as a linear lumped mass-spring and the seismic Isolator as an equivalent spring-damper. Time history analyses are performed for the 1940 El Centre earthquake with linear amplification. In the analysis 5% of structural damping is used for the superstructure. The effects of high damping rubber bearing on seismic response of the superstructure in base isolated system are evaluated for four stiffness model types. The acceleration responses in base isolated PWR superstructure with high damping rubber bearings are much smaller than those in fixed base structure. In the higher strain region where stiffness behaves non-linearly, the acceleration responses modelled by one equivalent stiffness are smaller than those in nonlinear spring model, and the higher stiffness spring model of isolator exhibits larger peak acceleration response at superstructure in the frequency range above 2.0 Hz. when subjected to linearly amplified 1940 El Centre earthquake.

  • PDF