• Title/Summary/Keyword: Isolation Technology

Search Result 1,841, Processing Time 0.034 seconds

The study of isolation driver for Reversible Power Converter (가역전력변환기 구동의 절연에 관한 연구)

  • Chun, J.H.;Lee, H.W.;Taniguchi, Hatsunori
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1349-1351
    • /
    • 2005
  • In this paper discusses isolation driver of single phase AC-DC reversible power converter The reversible power converter driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality with out filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/BC-AC multi-level reversible converter.

  • PDF

Combining approach in Fault Detection and Isolation for GPS applications

  • Chey, Jay-Won;Jee, Gyu-In;Lee, Jang-Gyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1949-1952
    • /
    • 2004
  • GPS is widely used for outdoor positioning in many applications. But it is not suitable for positioning in an obstacle environment such as urban area, tunnels and so on, due to variable signal level. So new technology of the positioning is required to provide the consistent error level regardless of any changes in any environment. Abrupt changes of GPS signal can be detected by various fault detection and isolation methods. Conventional FDI (Fault Detection and Isolation) methods are categorized into two approaches. One approach is the snapshot method that uses measurements only at present step. The other approach is the filtering method that uses measurements stacked from previous step to present step. The FDI result of the snapshot method can be considered reliable independently with previous results and the FDI result of the filtering method is more reliable and detection time is a little longer. Therefore combining approach of two methods is proposed for increasing FDI performance in this paper. Three approaches that are the snapshot method, the filtering method and the combining method are compared to show the probability of correct FDI in simulations. The combining approach presents best result of FDI among them and shows the consistent accuracy irrespective of any changes in outdoor environment.

  • PDF

An Interference Isolation Method for Wireless Power and Signal Parallel Transmissions on CPT Systems

  • Zhou, Wei;Su, Yu-Gang;Xie, Shi-Yun;Chen, Long;Dai, Xin;Zhao, Yu-Ming
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.305-313
    • /
    • 2017
  • A novel interference isolation method is proposed by using several designed coils in capacitive power transfer systems as isolation impedances. For each designed coil, its stray parameters such as the inter-turn capacitance, coil resistance and capacitance between the coil and the core, etc. are taken into account. An equivalent circuit model of the designed coil is established. According to this equivalent circuit, the impedance characteristic of the coil is calculated. In addition, the maximum impedance point and the corresponding excitation frequency of the coil are obtained. Based on this analysis, six designed coils are adopted to isolate the interference from power delivery. The proposed method is verified through experiments with a power carrier frequency of 1MHz and a data carrier frequency of 8.7MHz. The power and data are transferred parrallelly with a data carrier attenuation lower than -5dB and a power attenuation on the sensing resistor higher than -45dB.

A Study on Soft Switching Buck-Boost Converter added Electric Isolation (소프트 스위칭에 의한 절연형 벅-부스트 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young;Lee, Bong-Seob;Choi, Shin-Hyeong;Kim, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.922-923
    • /
    • 2008
  • This paper is proposed to a novel DC-DC buck-boost converter added electric isolation by using a soft switching method. To be achieved of high efficiency system, the proposed converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

A Study on the Characteristic analyses of High Performance Buck-Boost Converter added Electric Isolation (고성능 절연형 벅-부스트 컨버터의 특성 해석에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Do-Young;Lee, Bong-Seob;Kim, Choon-Sam;Shim, Jae-Sun;Yang, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.142-144
    • /
    • 2008
  • This paper is studied on the characteristic analyses of a high performance buck-boost converter added electric isolation by using a soft switching method. To be achieved of a high performance system, the proposed buck-boost converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a Partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with the system development of high efficiency. The soft switching operation and system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (II-Proposal for the Seismic Design Procedure) (마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(II-내진설계 절차 제안))

  • Gil, Heungbae;Park, Sun Kyu;Han, Kyoung Bong;Yoon, Wan Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.169-178
    • /
    • 2020
  • In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the "Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges" is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.

Dynamic characteristics of combined isolation systems using rubber and wire isolators

  • Lee, Seung-Jae;Truong, Gia Toai;Lee, Ji-Eon;Park, Sang-Hyun;Choi, Kyoung-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1071-1084
    • /
    • 2022
  • The present study aims to investigate the dynamic properties of a novel isolation system composed of separate rubber and wire isolators. The testing program comprised pure compressive, pure-shear, compressive-stress dependence, and shear-strain dependence tests that used full-scale test specimens according to ISO 22762-1. A total of 22 test specimens were fabricated and investigated. Among the tests, the pure compressive test was a destructive test that reached up to the failure stage, whereas the others were nondestructive tests before the failure stage. Similar to the pure-shear test, at each compressive-stress level in the compressive dependence test or at each shear-strain level in the shear-strain dependence test, the cyclic loading was conducted for three cycles. In the nondestructive tests, examination of the dynamic shear properties in the X-direction was independent of the Y-direction. The test results revealed that the increase in the shear strain increased the energy dissipation but decreased the damping ratio, whereas the increase in the compressive stress increased the damping ratio. In addition, a macro model was developed to simulate the load-displacement response of the isolation systems, and the prediction results were consistent with the experimental results.

Isolation of Dihydrophaseic Acid from Seed Extract of Nelumbo nucifera (연자육으로부터 식물호르몬 Dihydrophaseic Acid의 분리 및 동정)

  • Seo, Jee-Hee;Choi, Yeon-Hee;Yoo, Mi-Young;Hong, Kyung-Sik;Lee, Byung-Hoi;Yon, Gyu-Hwan;Kim, Young-Sup;Kim, Young-Kyoon;Ryu, Shi-Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.37 no.4 s.147
    • /
    • pp.290-293
    • /
    • 2006
  • Phytochemical investigation of the seed extract of Nelumba nucifera Gaerth (Nymphaeaceae) resulted in the isolation of a plant hormon, dihydrophaseic acid (1), a abscisic acid derivative. The chemical structure of 1 was elucidated by 2D-NMR spectroscopic analysis, COSY, DEPT, HMQC and HMBC.

Analysis of Radiation Characteristics of Plate-Inserted IBBD Array Antennas (평판이 삽입된 IBBD 배열 안테나의 복사 특성 분석)

  • Choi, Hwan-Gi;Choi, Hak-Keun;Kim, Do-Kyung;Jung, Young-Bae;Jeon, Soon-Ik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1213-1222
    • /
    • 2008
  • In this paper, the isolation of the IBBD array antenna is analyzed as functions of the element spacing and the height of the flat plate inserted between array elements for the intelligent antenna system. It is found that the isolation between array elements improves with increasing the array spacing. The array configuration with the plate between the elements is enhanced by about 13 dB more In the isolation than the one without the plate. The plate-inserted $4{\times}4$ elements IBBD array antennas are fabricated and the radiation characteristics are measured and analyzed for the various heights of the plate. It is found that the gain decreases slightly with increasing the height of plate but the shape of radiation pattern does not show a remarkable change.