• Title/Summary/Keyword: Isolation Level

Search Result 798, Processing Time 0.031 seconds

Design and fabrication of Diplexer for Dual-band GSM/DCS Application using High-Q Multilayer Inductors (고품질 적층형 인덕터를 이용한 이중 대역 GSM/DCS 대역 분리용 다이플렉서의 설계 및 제작)

  • Sim, Sung-Hun;Kang, Chong-Yun;Choi, Ji-Won;Yoon, Young-Joong;Yoon, Seok-Jin;Kim, Hyun-Jai
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.294-298
    • /
    • 2003
  • In this paper, the modeling and design of high-Q multilayer passives have been investigated, and multilayer diplexer for GSM/DCS applications has been designed and fabricated using the passives. To minimize the system, the configuration of a multilayer inductor has involved a square spiral structure. Modeling of a multilayer inductor was performed by the subsystems of distributed components, and using the modeling the optimal structures of the high-Q multilayer inductor could be designed by analyzing parasitics and couplings which affect their frequency characteristics. Multilayer diplexer for GSM/DCS application has been designed and fabricated using LTCC technology. LPF for GSM band had the passband insertion loss of less than 0.55 dB, the return loss of more than 12 dB, and the isolation level of more than 26 dB by locating attenuation pole at 1800 MHz. HPF for DCS band had the passband insertion loss of less than 0.82 dB, the return loss of more than 11 dB, and the isolation level of more than 38 dB by locating attenuation pole at 930 MHz.

  • PDF

Isolation and Characterization of a Thermophilic Bacillus sp. producing a Thermostable $\alpha$-glucosidase (내열성$\alpha$-glucosidase를 생산하는 호열성 Bacillus sp. 균주의 분리 및 특성)

  • 이용억
    • Journal of Life Science
    • /
    • v.8 no.4
    • /
    • pp.387-394
    • /
    • 1998
  • A thermophilic bacterium (strain DG0303) producing a thermostable $\alpha$-glucosidase was isolated from manure and identified as Bacillus sp. Strain DG0303 produced high level of $\alpha$-glucosidase compared with other thermophilic Bacillus strains. The cellular protein patterns were also compared with other Bacillus strains by sodium dodecyl sulfatepolyacrylamide gel electrophoresis(SDS-PAGE). On the basis of 16S rDNA analysis the Bacillus sp. DG0303 was found to be a member of Bacillus rDNA group 5. The optimum temperature for growth was 65$\circ$C and no growth was obtained at 40$\circ$C or 75$\circ$C. The optimum pH for growth was 5.5 to 8.5. $\alpha$-glucosidase activity was produced during growth and most activity was detected in the culture supernatant. The $\alpha$-glucosidase production was constitutive in the absence of carbohydrates. High level of enzyme activity was detected when the culture was grown on medium containing starch. Addition of glucose resulted in the repression of the $\alpha$-glucosidase production. The optimum pH and tempoerature for enzyme activity were pH 5.0 and 65$\circ$C, respectively. When analyzed by zymogram, the culture supernatant showed a single $\alpha$-glucosidase band with a molecular weight of approximately 60,000.

  • PDF

Design of the Resistive Mixer MMIC with high linearity and LO-RF isolation (고선형성과 높은 LO-RF 격리도를 갖는 새로운 구조의 저항성 Mixer MMIC 설계)

  • Lee, Kyoung-Hak
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.7-11
    • /
    • 2014
  • In this paper, we designed resistive MMIC mixer using $0.5{\mu}m$ p-HEMT process. This Mixer is designed to have a similar performance in -4 ~ 4 dBm local oscillator signal power level and to maintain a constant conversion loss and linear performance due to the variation of local signal. In order to have such characteristics, we designed new feedback circuit topology by using FET, and minimized performance change for LO signal power level variation, also obtain MMIC mixer characteristics which is able to apply in wideband. In the design result, When the LO signal power is -4 ~ 4 dBm, there was 6 dB conversion loss and it came up with the excellent result that IIP3 got over 30 dBm in 0.5 ~ 2.6GHz frequency band.

Relationship between Health-Related Physical Fitness, Cognitive Function and Isolation in the Elderly (노인의 건강관련체력과 인지기능 및 고립감의 관계)

  • Lee, Kyung-Ha;Choi, Jae-won;Lee, Na-Eun;Kang, Sung-Goo;Jung, Hye-Yeon;Chun, Myung-Up;Yoo, Ha-Na;Park, Ji-Su;Park, Jung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.285-301
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between health-related physical fitness factors and cognitive function and isolation on 308 elderly over 65 years old in Seoul and Gyeonggi do. The measuring instrument were as follows demographic characteristics(age, education level, drink, spouse, participation on in exercise) and health-related physical fitness(grip strength, leg strength, flexibility, balance), cognitive function (MMSE-K, digit span test) and emotional/social aspects of loneliness and isolation was measured. As a results, first, depending on the degree of demographic characteristics of elderly had significant difference. Second, health-related physical fitness and cognitive function are positive correlated, negative correlation between cognitive function and isolation. Third, health-related physical fitness of the elderly had a significant effect on cognitive function. Fourth, health-related fitness of the elderly had a significant effect on isolation. Fifth, the cognitive function of the elderly had a significant effect on isolation. In conclusion, this study will provide basic data for future aged man welfare studies and contribute to extended studies.

A Study on Need for Safe Baseline Isolation Standard for Chemical Plant Equipment (화학공장 설비의 안전한 격리 표준 필요성에 대한 연구)

  • Su-Ji Choi;Sang-Gil Kim;Gyu-Sun Cho
    • Industry Promotion Research
    • /
    • v.8 no.4
    • /
    • pp.37-46
    • /
    • 2023
  • Due to the aging, advancement, and complexity of chemical facilities, non-routine work such as facility inspection, repair, or maintenance work is increasing. Of the 1,483 accidents that occurred over the past 10 years at chemical product manufacturing sites subject to PSM, accidents that occurred during non-routine work accounted for 56% (932 Cases) of the total. It can be seen that more accidents occur during non-routine work than during routine work. In particular, in order to improve the economy and efficiency of factory operation, there are cases where some facilities are stopped without stopping the entire factory and then inspection, repair, or maintenance work is performed while isolated from the operating facilities. Therefore, first, a safe isolation method must be selected by establishing an isolation standard (Baseline Isolation Standard) based on the chemicals handled, operating conditions, and risk level of the equipment in the chemical plant. Second, since current domestic laws and standards do not suggest the need for specific quarantine standards, it is necessary to institutionalize the preparation of quarantine standards. Technical and institutional improvements are needed to prevent fires, explosions, and poisoning accidents caused by leaks of chemical substances.

A Study on the Design and Electrical Characteristics of High Performance Smart Power Device (고성능 Smart Power 소자 설계 및 전기적 특성에 관한 연구)

  • Ku, Yong-Seo
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.1-8
    • /
    • 2003
  • In this study, the high performance BCD device structure which satisfies the high voltage and fast switching speed characteristics is devised. Through the process and device simulation, optimal process spec. & device spec. are designed. We adapt double buried layer structure, trench isolation process, n-/p-drift region formation and shallow junction technology to optimize an electrical property as mentioned above. This I.C consists of 20V level high voltage bipolar npn/pnp device, 60V level LDMOS device, a few Ampere level VDMOS, 20V level CMOS device and 5V level logic CMOS.

  • PDF

A winding design of Tap Level Converter (Tap Level 제어 전력 변환기의 권선설계)

  • Chun J.H.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.53-55
    • /
    • 2006
  • In this paper discusses winding methode of single phase AC-DC reversible power converter The reversible power converter driven by multi Tap winding at both side switching control. It has a advantage that simple drive of main switching device. and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Cost Effectiveness Evaluation of Seismic Isolated Bridges in Low and Moderate Seismic Region (중약진 지역에서의 지진격리교량의 비용효율성 평가)

  • 고현무
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.440-447
    • /
    • 2000
  • In order to evaluate the cost effectiveness of seismic isolation for bridges in low and moderate seismic region, a method of calculation minimum life-cycle cost of seismic-isolated bridges under specific acceleration level and soil condition is developed. Input ground motion is modeled as spectral density function compatible with response spectrum for combination of acceleration coefficient and site coefficient. Failure probability is calculated by spectrum analysis based on random vibration theories to simplify repetitive calculations in the minimization procedure. Ductility of piers and its effects on cost effectiveness are considered by stochastic linearization method. Cost function and cost effectiveness index are defined by taking into consideration the characteristics of seismic isolated bridges. Limit states for calculation of failure probability are defined on superstructure, isolator and pier, respectively. The results of example design and analysis show that seismic isolation is more cost-effective in low and moderate seismic region than in high seismic region.

  • PDF

비 격리교량의 연성도를 목표로 하는 지진격리교량의 응답수정계수

  • 고현무
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.432-439
    • /
    • 2000
  • According as ground acceleration becomes to exceed gravity acceleration recently, design is impossible or economical efficiency is poor in existing seismic design method. So increase of seismic isolated bridges is currently in progress. However, because base isolation design method is developed in high seismic regions. it may not be compatible in Korea. Therefore, this research has objective to evaluate ductility of pier and response modification factor according to the ductility of pier in seismic isolated bridges and to adapt to seismic characteristics in Korea. For this purpose, nonlinear analysis is accomplished with so many time histories derived from spectral density function compatible with response spectrum described in the design code and base isolation system modeled linear system, bi-linear system, and friction system. Through application of the proposed method, we had result that it may be compatible that response modification factor for the seismic isolated bridges is smaller than half of that for the conventional bridges when natural period of structures exceeds proper level.

  • PDF

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.