• 제목/요약/키워드: Isolated power supply

검색결과 86건 처리시간 0.026초

제주지역 계통특성을 고려한 다기(Multi-Infeed) HVDC 시스템 운전 방안에 관한 연구 (A Study on the Operation Strategies of Multi-Infeed HVDC System in Jeju Island Power System)

  • 이승엽;윤민한
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1675-1681
    • /
    • 2017
  • As recently the demand on electric power has been increasing, the requirement of power supply reliability has been increased. Accordingly, the number of HVDC transmission systems in the world has been steadily increased, which have been installed in the power system to transmit a large capacity power to the long distant and interconnect the power grid between different countries. etc. #1 HVDC Transmission System was installed between Haenam and Jeju island in 1998, which is the first HVDC system furnished in korea. and has been operated until now. Before #1 HVDC Transmission System being installed, the power system of the Jeju Island is a isolated power system from that of Korea mainland. After the construction of #1 HVDC the system has made the Jeju power system more reliable and also been able to supply the mainland power, which was cheaper than that of Jeju island, to Jeju island. The construction of additional HVDC transmission system between mainland and the Jeju Island has been currently underway to cope with recent changes of the power market of the Jeju island, for examples the increase of power demand and the capacity of wind power generation. etc. #2 HVDC Transmission System construction was completed in 2012. #3 HVDC Transmission System will be also installed according to the plan. If all goes as planned, the Jeju power system will be operated with Multi-Infeed HVDC system connected to mainland power system. So the additional studies are needed in order to maintain the stability of the Jeju power system and get the efficiency of the Multi-Infeed HVDC system. Therefore, in this paper, the optimal operation strategies of the Multi-Infeed HVDC system between the mainland of Korea and the Jeju are suggested to ensure the stability of the power system in Jeju Island when the Multi-Infeed HVDC system is operated between two power system.

태양광발전을 위한 새로운 3상한 시스템에 관한 연구 (A novel three-phase power system for a simple photovoltaic generator)

  • 박성준;김정훈;김진영;김종현;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.181-184
    • /
    • 2005
  • Operating conditions of photovoltaic power generator is very sensitive to the PV modules. The PV module's control is an importance issue in the removing DC ripple noise. In this paper, the phase-shifted-carrier technique, which is a new three-step dc-dc power multi-converter schemes, is applied to solar generator system to improve the output current waveform. The novel type of three-step dc-dc converter presented has many features such as the good output waveform, high efficiency, low switching losses, low acoustic noise. The circuit configuration is constructed by the conventional full-bridge type converter circuit using the isolated DC power supply for which the solar cell is very suitable. In the end, a circuit design for understanding three-step dc-dc converter and new solar power system were presented

  • PDF

20W급 보조전원용 다출력 QR 플라이백 컨버터의 출력전압 안정화에 관한 연구 (A Study on Output Voltage Stabilization of 20W Class Multi-output QR Flyback Converter for Auxiliary Power)

  • 유정상;길용만;김현배;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.157-160
    • /
    • 2021
  • In this paper, a 20W class multi-output QR flyback converter for auxiliary power supply was designed to stabilize 4 output voltages, and the efficiency and load characteristics were compared and analyzed. It was checked if each output affects other output characteristics through experiment. As a result, the experimental circuit reached a high efficiency of 82.5% or more at a load power of over 20W, and the maximum power loss was 2.6W. Consequently, it was confirmed that all of 4 output voltages of the multi-output QR flyback converter constructed in this paper were stabilized within 0.5% in full-load range, and each output was independently controlled in an electrically isolated state.

소방 방재설비용 연료전지 발전시스템의 비절연형 고효율 전력변환기 설계 (High Efficiency Power Conversion System of Non Isolated Type Applied in Fuel Cell Generator Used to Fire Prevention Installation)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.19-26
    • /
    • 2006
  • 본 논문은 예비 전력공급설비의 일환으로 비상시 소방 방재설비에 적용되는 연료전지 발전시스템에 대해 연구된다. 제안된 시스템은 비상시 상용 전력공급의 차단에 대비하여 소방 방재설비들의 전력공급원으로 이용된다. 연료전지 발전시스템에서 가장 손실이 큰 부분은 전력변환부이다. 또한 전력변환부의 손실은 전력변환을 위해 사용된 전력용 반도체 스위치의 스위칭 손실로 주어진다. 본 논문에서는 이러한 연료전지 발전시스템의 출력을 최대한 활용하기 위하여 부분공진의 기법이 적용된 고효율의 전력변환기가 제안된다. 또한 연료전지 발전시스템에 적용된 고효율 전력변환기는 비절연형으로 설계되고 사용된 제어스위치들은 새로운 소프트 스위칭 회로토폴로지에 의해 무손실로 동작되어 시스템의 효율을 증대시킨다. 다양한 컴퓨터 시뮬레이션과 특성실험을 통해 이론적 해석의 타당성이 입증된다.

  • PDF

Design of a Digital PWM Controller for a Soft Switching SEPIC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.152-160
    • /
    • 2004
  • This paper presents analysis, modeling, and design of a low-harmonic, isolated, active-clamped SEPIC for future avionics applications. Simpler converter dynamics, high switching frequency, zero voltage-Transition-PWM switching, and a single-layer transformer construction result. This paper describes complete design of a digital controller for a high-frequency switching power supply. Guidelines for the minimum required resolution of the analog-to-digital converter, the pulse-width modulator, and the fixed-point computational unit is derived. A design example based on a SEPIC converter operating at the high switching frequency is presented. The controller design is based on direct digital design approach and standard root-locus techniques.

커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로 (Low-cost crowbar system and protection scheme in capacitor bank module)

  • 임근희;조주현;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

국내 계통분리 상정시 과도 상태 분석 (Transient state Analysis at domestic electric power system separation)

  • 이소영;장병태;조경보;오화진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.281-283
    • /
    • 2003
  • In the rower systems of Korea, there is little chance of the separation of power systems as well as a blackout due to the large disturbance. However, that possibility shouldn't be ignored, and always exists. In this paper, we present the results of the analysis of transient stabilities for the case of contingencies of power systems separation in the isolated power systems where the regional concentration of supply and demand exists.

  • PDF

차량 충전용 고효율 절연형 컨버터 개발 (The development of high efficiency isolated converter for vehicle charger)

  • 박민준;진호상;이건희;황광규;김우섭;이재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.101-102
    • /
    • 2015
  • This paper is about the suggestion for the development in the commercialization for 3.6kW Class On-Board charger. It is suggesting non-insulation AC-DC Boost Power Factor correction circuit and insulation DC-DC resonant Converter for circuit design. In addition, Input AC voltage in the power supply is DCM control which can be designed to decrease the inductance for the inductor size to be reduced. DCM controls and Interleaved PFC can be designed to decrease the inductor size increasing the power conversions. Also, using the insulation DC-DC resonant converter, the efficiency can be increased. This system is verified using prototype hardware.

  • PDF

주파수 안정도 유지를 위한 부하차단 시뮬레이션-가스분리플랜트 사례 (LOAD SHEDDING SIMULATION FOR MAINTAINING FREQUENCY STABILITY-GAS SEPARATION PLANT CASE)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.72_73
    • /
    • 2009
  • The industrial power system has the radial plant distribution system and domestic generators to supply the essential loads. When the system is isolated from the utility tie line, the system frequency drops resulting in the trip of generators. The load shedding scheme shall be properly designed to secure the essential load. In this paper two kinds of load shedding schemes, those are, the Fast Act Load Shedding(FALS) and Under Frequency Load Shedding(UFLS) are simulated and compared taking an example of petrochemical gas separation plant.

  • PDF

Weak Feed 전력계통의 블랙스타트와 고조파 공진 사례연구 (A Case Study of Harmonic Resonance & Black Start in Weak Feed Power System)

  • 박영철;이은섭;손효수;이석현
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.40-50
    • /
    • 2016
  • In order to recover the power system during the wide power outage or power failure in the power plant, black start system should be properly operated without any problem. Especially power for black start in the geographically isolated areas of electric island is supplied from small emergency start-up generator, and loads are aux systems of gas turbines such as SFC(Static frequency converter). This paper introduces the international practices to overcome the voltage drop problem with harmonics of the system having the DC output such as SFC during black start in weak feed system and analyzes the relationship between house load inputs and harmonics. By varying the house load and input of power supply, this paper identified boundaries between weak feed and strong feed power. In order to verify the theory of stable condition in weak feed power system with DC output, house load is simulated using ETAP. Additionally MATLAB was used for harmonic analysis between the load inertia moment and non load inertia moment.