• Title/Summary/Keyword: Isolated grid

Search Result 73, Processing Time 0.029 seconds

Simplified Wind Turbine Modeling and Calculation of PCC Voltage Variation according to Grid Connection Conditions (간략화된 풍력발전기 모델링과 계통연계 조건에 따른 PCC 전압 변동량 계산)

  • Im, Jl-Hoon;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2402-2409
    • /
    • 2009
  • This paper proposed a simple and helpful analysis model of voltage variation in order to predict the voltage variation at PCC (Point of Common Coupling), when a wind turbine is connected in an isolated grid. The PCC voltage flucuates when the wind turbine outputs active power to an isolated grid. This voltage variation is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And It is different according as where wind turbine is connected. To solve the problem of voltage variation, this paper proposed the reactive power control. To verify the proposed analysis model, this paper utilized PSCAD/EMTDC Simulation and the field measurement data of the voltage variation during the wind power generation.

A Study on Grounding Resistance Measurement of Power Supplying Substation using Grounding Current Division Factor and FOP Profile Method (접지전류 분류계수 및 전위강하곡선법을 이용한 운전 중인 변전소의 접지저항 측정 방법에 관한 연구)

  • An, Yong-Ho;Choi, Jong-Ki;Kim, Yong-Hak;Han, Jeong-Yeol;Lee, You-Jin;Han, Byoung-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.100-107
    • /
    • 2011
  • Since transmission and distribution neutral wires are connected with a substation grounding grid, it is very difficult to measure grounding resistance of isolated substation grounding grid after the substation is energized. It is impractical to isolate the grounding grid from other parallel connections such as distribution line neutrals and overhead ground wires for grounding resistance measurement only. In this paper, we proposed and demonstrated a novel measurement method of grounding resistance of isolated substation grounding grid. For this method, grounding current division factor and conventional FOP(Fall-Of-Potential) profiles were measured at power supplying 154[kV] substation. The obtained FOP profile was processed with the measured grounding current division factor to produce the grounding resistance of isolated grounding grid. Simulated FOP profile agreed well with the measured one showing the validity of the proposed method.

Microgrid Island Operation Based on Power Conditioning System with Distributed Energy Resources for Smart Grid (스마트 그리드를 위한 분산자원과 전력변환장치 기반 마이크로그리드 독립운전)

  • Heo, Sewan;Park, Wan-Ki;Lee, Ilwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.5
    • /
    • pp.1093-1101
    • /
    • 2017
  • Microgrid as a unit component consisting a smart grid is an isolated system, which has a decentralized power supply system. This paper proposes an electrical isolation of the microgrid from the utiliy grid based on a power conditioning system, and also proposes an operation method maintaining the isolated state efficiently using diverse distributed energy resources such as renewable energy sources and energy storage system. The proposed system minimizes the influence of the grid connection on the internal load though a phase detection and synchrnoization to the utiligy grid and the microgrid can be stable even if the grid is failed.

A Simple Prediction Model for PCC Voltage Variation Due to Active Power Fluctuation of a Grid Connected Wind Turbine

  • Kim, Sang-Jin;Seong, Se-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.85-92
    • /
    • 2009
  • This paper studies the method to predict voltage variation that can be presented in the case of operating a small-sized wind turbine in grid connection to the isolated small-sized power system. In order to do this, it makes up the simplified simulation model of the existing power plant connected to the isolated system, load, transformer, and wind turbine on the basis of PSCAD/EMTDC and compares them with the operating characteristics of the actual established wind turbine. In particular, it suggests a simplified model formed with equivalent impedance of the power system network including the load to analytically predict voltage variation at the connected point. It also confirms that the voltage variation amount calculated by the suggested method accords well with both simulation and actually measured data. The results can be utilized as a tool to ensure security and reliability in the stage of system design and preliminary investigation of a small-sized grid connected wind turbine.

Flyback-type Snubber of High Efficiency for 10kV IGCT in 7MW Wind Turbine Systems

  • Shirmohammadi, Siamak;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.359-360
    • /
    • 2015
  • 10kV IGCT has been recently developed and has the potential to push wind turbine systems to higher power and voltage rating. Converters employing IGCTs need snubber and OVP circuit to limit the rate of rise of current and peak over voltage across IGCT during turn on and off state respectively. The conventional RCD snubber which is used in such power converter dissipates a significant amount of power. In order to reduce the amount of energy lost by conventional RCD snubber, this paper proposes an isolated inductor snubber circuit that not only meets all of the IGCTs characteristics during on and off-state but also significantly saves the power loss. Loss analysis of conventional di/dt snubber and OVP circuit is performed for the 3-level NPC type back-to-back VSC supplied from grid voltage of 6.9kV. In comparison with the conventional snubber, isolated inductor snubber has a fewer number of components and improved efficiency leading to a reliable and efficient wind turbine systems.

  • PDF

Performance Comparison of Signal Reference Grid and Insulated/Isolated Ground Using HIFREQ Simulator (기준신호용 그리드와 절연/독립접지방식의 비교)

  • Paik, Seung-Hyun;Kim, Kyung-Chul;Choi, Jong-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.69-73
    • /
    • 2004
  • This paper deals with the transient performance of zero signal reference grid(ZSRG) and insulated/isolated ground(IG) in case of lightning strike or surge currents in buildings. Using HIFREQ, which is a commercial code for electromagnetic field analysis, the difference of transient performances of ZSRG and IG type grounding structure have been presented based on the numerical calculations. It is expected that the quantitative and numerical calculation based analysis, which is adopted in this paper, will attribute to the selection of optimal grounding method in the intelligent buildings.

A Dual Buck Three-Level PV Grid-Connected Inverter

  • Ji, Baojian;Hong, Feng;Wang, Jianhua;Huang, Shengming
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.910-919
    • /
    • 2015
  • The use of a PV grid-connected inverter with non-isolated topology and without a transformer is good for improving conversion efficiency; however, this inverter has become increasingly complicated for eliminating leakage current. To simplify the complicated architecture of traditional three-level dual buck inverters, a new dual Buck three-level PV grid-connected inverter topology is proposed. In the proposed topology, the voltage on the grounding stray capacitor is clamped by large input capacitors and is equal to half of the bus voltage; thus, leakage current can be eliminated. Unlike in the traditional topology, the current in the proposed topology passes through few elements and does not flow through the body diodes of MOSFET switches, resulting in increased efficiency. Additionally, a multi-loop control method that includes voltage-balancing control is proposed and analyzed. Both simulation and experimental results are demonstrated to verify the proposed structure and control method.

Novel Topology and Control Strategy of HVDC Grid Connection for Open Winding PMSG based Wind Power Generation System

  • Zeng, Hengli;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.215-221
    • /
    • 2014
  • To satisfy the high voltage direct current (HVDC) grid connection demand for wind power generation system, a novel topology and control strategy of HVDC grid connection for open-winding permanent magnet synchronous generator (PMSG) based wind power generation system is proposed, in which two generator-side converter and two isolated DC/DC converters are used to transmit the wind energy captured by open winding PMSG to HVDC grid. By deducing the mathematic model of open winding PMSG, the vector control technique, position sensorless operation, and space vector modulation strategy is applied to implement the stable generation operation of PMSG. Finally, the simulation model based on MATLAB is built to validate the availability of the proposed control strategy.

MUTUAL COUPLING EFFECTS ON THE PERFORMANCE OF A SPACE-TAPERED RECTANGULAR PHASED ARRAY (공간체감된 구형 위상어레이의 성능에 미치는 상호결합의 영향)

  • Chang Byong-Kun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.415-421
    • /
    • 2005
  • The radiating or receiving characteristics of array elements (i.e., antennas) are changed from those of isolated elements due to mutual coupling effects and the array performance becomes different from those originally designed by assuming isolated elements. The effects of mutual coupling on the performance of a rectangular array with triangular grid geometry of dipoles above a ground plane are discussed with respect to element pattern. The concept of element gain function is used to examine the effects of mutual coupling on the array performance in terms of sidelobe level in the uniformly spaced and space-tapered rectangular arrays with triangular grid geometry of dipoles. It was shown that the sidelobe performance improved in the space-tapered array compared to the uniformly spaced array in the presence of mutual coupling effects. Computer simulation results are presented.

Stability Control of Energy Storage Voltage Source Inverters in Isolated Power Systems

  • Hu, Jian;Fu, Lijun
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1844-1854
    • /
    • 2018
  • Isolated power systems (IPS) are often characterized by a weak grid due to small power grids. The grid side voltage is no longer equivalent to an ideal voltage source of an infinitely big power grid. The conversion control of new energy sources, parameter perturbations as well as the load itself can easily cause the system voltage to oscillate or to become unstable. To solve this problem, increasing the energy-storage power sources is usually used to improve the reliability of a system. In order to provide support for the voltage, the energy-storage power source inverter needs an method to control the voltage source. Therefore, this paper has proposed the active damping control of a voltage source inverter (VSI) based on virtual compensation. By simplifying the VSI double closed-loop control, two feedback compensation channels have been constructed to reduce the VSI output impedance without changing the characteristics of the voltage gain of a system. This improvement allows systems to operate stably in a larger range. A frequency-domain analysis, and simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method.