• Title/Summary/Keyword: Iso surface

Search Result 319, Processing Time 0.028 seconds

Identification of an Actinomycetes Strain, MSA-1, Originated from Sponge, Halichondria okadai, and its Antimicrobial Component (검정해면으로부터 항균성을 가진 방선균의 분리 동정 및 항균물질의 구조)

  • LEE Jong-Soo;CHOI Jong-Duck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.516-522
    • /
    • 1998
  • An Actinomycetes strain, MSA-1, containing antimicrobial component was isolated from the black sponge, Halichondzia okadai, and was identified to a genus level by morphological and chemotaxonornic methods. The gray colored spores were oval type with smooth surface and formed flexibilis spore chains. The cell wall of this strain was type I containing D-aminopimellic acid (D-DAP) and no specific sugar was detected. Phospholipid of the cell membrane was PII type including phophoethanolamine and the major fatty acids of total lipid were branched anteiso-15 : 0, iso-16 : 0, 16 : 0 and iso-17 ; 0. From these results and other characteristics described in the Bergey's Manual, this strain was identificated as a Streptomyces sp. Meanwhile, 10mg of pale yellow colored antimicreobial component was isolated by HPLC method from the cultured Streptomyces sp. (70g of cryophillized mycellis). By crystallographyc analysis, HIRESMS and NMR assignment, the antimicrobial component produced from the strain MSA-1 was elucidated as the staurosporine (indolo[2,3-a]carbazole alkaloid).

  • PDF

A Study on Establishment of Design Criteria for Development of New TWSIs (신형 점자블록 개발을 위한 설계원칙 설정 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Kim, Sang-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Since the end of the 1990s the question of detecting blind and vision-impaired persons' tactile walking surface indicators have been rasied, the study of detecting tactile walking surface indicators has been started in Japan, German, and Sweden. Through the study, Japan, German, Sweden, and international's standard was revised. The Korean standard of tactile walking surface indicators was revised in 2013, the remarkable point was missed. Therefore, this study suggested deriving a range of types and dimensions of tactile walking surface indicators reasonable, and presenting the design principles for the development of new tactile walking surface indicators though domestic and international literature review. Method: This study was proceeded by comparison analysis of results from various tactile walking surface indicators' literature review from Japan, German, and Sweden, the most suitable range of types and dimensions was abstracted. Then, the range of types and dimensions was compared to the international standards and international reference standard, the ground rules were confirmed to apply new tactile walking surface indicators design. Results: Rationally, the wide and diameter of projecting line and projecting point should be downsized in order to improve detecting blind and vision-impaired persons' tactile walking surface indicators. And with same purpose, the ratio of the wide and diameter of projecting line and projecting point should be decided. The design of the tactile walking surface indicators in addition to the size and spacing of the protrusions should be to reflect the common elements that have been suggested a number of standard criteria. Implication: In this study, the design principles was derived through test results and theoretical studies, and new tactile walking surface indicators would need to be validated in local user.

Development of Strength and Durability Estimation System for Power Transmission Cylindrical Gears (원통치차의 강도평가 시스템 개발연구)

  • 정태형;변준형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.112-119
    • /
    • 1993
  • A strength and durability estimation system of involute cylindrical gears which are commonly used as power transmission devices is developed on the personal computer, which analyzed and/or evaluates the gear design and the service performance at the point of view of strength and durability. The typical considerations are the bending strength and the sunface durability, and the strength and durability estimations are carried out using the reliable standards of AGMA&ISO. In addition, the finite element analysis (FEM) of tooth bending stress is conducted in order to compare the real maximum stress with the estimaed bending stress by the standard. Therefore, the system is built so that the variables or factors considered differently in those standards and the strength & durability are appraised seperately by each method, and a series of the estimation processes is integrated into the system can be used in the initial design at the view point of strength and durability. And it is useful to the purpose of the trouble-shooting of gear system and the purpose of introducing the methods for maintaining design strength in service, with appraising the strength and durability after design or with appraising the influencing factors, as a whole. Therefore, this strength and durability estimation system can help the aim of automatic design of cylindrical gears.

Determination of the pH of Iso-Selectivity of the Interfacial Diffusion Layer of Fe

  • Ha, Heon Young;Kwon, Hyuk Sang
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-44
    • /
    • 2008
  • Passive metal forms an interfacial diffuse layer on the surface of passive film by its reaction with $H^+$ or $OH^-$ ions in solution depending on solution pH. There is a critical pH, called pH point of iso-selectivity ($pH_{pis}$) at which the nature of the diffuse layer is changed from the anion-permeable at pH<$pH_{pis}$ to the cation-permeable at pH>$pH_{pis}$. The $pH_{pis}$ for a passivated Fe was determined by examining the effects of pH on the thickness of passive film and on the dissolution reaction occurring on the passive film under a gavanostatic reduction in borate-phosphate buffer solutions at various pH of 7~11. The steady-state thickness of passive film formed on Fe showed the maximum at pH 8.5~9, and further the nature of film dissolution reaction was changed from a reaction producing $Fe^{3+}$ ion at $pH\leq8.5$ to that producing $FeO_2{^-}$ at $pH\geq9$, suggesting that the $pH_{pis}$ of Fe is about pH 8.5~9. In addition, the passive film formed at pH 8.5~9, $pH_{pis}$, was found to be the most protective with the lowest defect density as confirmed by the Mott-Schottky analysis. Pitting potential was decreased with increasing $Cl^-$ concentration at $pH\leq8.5$ due probably to the formation of anion permeable diffuse layer, but it was almost constant at $pH\geq9$ irrespective of $Cl^-$ concentration due primarily to the formation of cation permeable diffuse layer on the film, confirming again that $pH_{pis}$ of Fe is 8.5~9.

A Study on Effective Integration for IMS and ISO Management Systems (정보화경영체제와 ISO 경영시스템의 효과적인 통합방안 연구)

  • Kim, Kyung-Ihl
    • Journal of Convergence Society for SMB
    • /
    • v.3 no.2
    • /
    • pp.41-49
    • /
    • 2013
  • According to the globalized trend in the market, corporations of complex business environment have introduced variety of ISO standard in management field to accept all of client demands. However, in most cases, each special management systems have been forced and operated by way of independent form because of surface reason such as international standard or matter of internal concern. Because of this reason, some organization cannot utilize not only corporation and function task but also valuable system data. As a result, these inefficiency cause contradiction of stake, and come into obstacle in competitive situation. Thus, corporates consider plan that they more efficiently by linking different management systems. This is reason why need integration management system. To achieve desired goals by uniting two or more management systems, corporations should understand purpose, form and level. Ultimate purpose of this study is pushing to systematic cooperation by recognizing positive effect of combination, understanding progress step and apprehend problems.

  • PDF

Corrosion Behavior of Titanium for Implant in Simulated Body Fluids (인공 체액 조건에서 임플랜트용 티타늄 소재의 부식 특성)

  • 이중배;최기열
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.110-118
    • /
    • 2004
  • The corrosion of pure titanium (CP- Ti Grade 2) and titanium alloy (Ti6Al4V ELI) were studied under various conditions of simulated body fluids. The static immersion test and the electrochemical test were performed in accordance with ISO 10271 : 2001. For the electrochemical test, the open circuit potential was monitored as a function of time, and the cyclic polarization curve was recorded. The corrosion resistance was evaluated from the values of corrosion potential, passivation current density, breakdown potential, and the shape of hysteresis etc. The effects of alloy type, surface condition, temperature, oxygen, and constituents in the fluids such as acid, chloride were estimated. Both specimens had extremely low dissolution rate in the static immersion test. They showed strong passivation characteristics in the electrochemical test. They maintained negligible current density throughout the wide anodic potential range. The passive layer was not broken up to 2.0 V (vs. SCE). The hysteresis and the shift of passivation potential toward the anodic direction was observed during the reversed scan. The passivation process appeared to be accelerated by oxygen in air or that dissolved in the fluids. The passivation also proceeded without oxygen by the reaction of constituents in the fluids. Acid or chloride in the fluids, specially later weakened the passive layer, and then induced higher passivation current density and less shift of passivation potential in the reversed scan. CP-Ti Grade 2 was more reactive than Ti6Al4V ELI in the fluids containing acid or chloride, but thicker layer produced on its surface provided higher corrosion resistance.

자유곡면 볼엔드 밀링공정에서 CUSP PATTERN 조정

  • 심충건;양민양
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.106-110
    • /
    • 2001
  • The ball-end milling process is widely used in the die/mold industries, and it is very suitable for the machining of free-form surfaces. However, this process is inherently inefficient process to compared with the end-milling or face milling process, since it relays upon the machining at the cutter/surface contact point. The machined part is the result of continuous point-to-point machining on the free-form surface. And cusps (or scallops) remain at the machined part along the cutter paths and they give the geometrical roughness of the workpiece. Thus, for the good geometrical roughness of the workpiece, it is required very tightly spaced cutter paths in this ball-endmilling process. However, with the tight cutter paths, the geometrical roughness of the workpiece is not regular on the workpiece since the cusp height is variable in the previously developed ISO-parametric or Cartesian machining methods. This paper suggests a method of tool path generation which makes the geometrical roughness of workpiece be constant through the machined surface. In this method, Ferguson Surface design Model is used and cusp height is derived from the instantaneous curvatures. And, to have constant cusp height, an increment of parameter u or v is estimated along the reference cutter path. In ball-end milling experiments, the cusp pattern was examined, and it was proved that the geometrical roughness could be regular by suggested tool path generation method.

An Experimental Study on the Effect of Air Space on the Absorption Property of Composite Absorption System (배후공기층이 복합흡음구조의 흡음특성에 미치는 영향에 관한 실험적 연구)

  • Oh, Yang-Ki
    • KIEAE Journal
    • /
    • v.1 no.2
    • /
    • pp.47-54
    • /
    • 2001
  • Single sound absorbers such as porous materials, panels, and Helmholts resonators have limited performance with some extents of frequency region. For example, porous materials do not attenuate low frequency sounds, while panels do not absorb high frequency sounds. Composite absorption structure with coverings, porous materials, and air gaps are an alternative for wide band sound absorption. Slits, panels, perforated panels are those materials for coverings, glass wool, mineral wool, polyester, and polyurethane are frequently used porous materials. Air gap between the porous material and background surface is one of major factors which governs the absorption characteristics of composite absorption structures, especially in the low frequency area. Calculations and measurements show that the absorption coefficients of composite absorption structure, in mid and low frequency bands, are getting higher with increased air gaps. Perforated panels rather than slits and panels are good coverings with higher number as far as absorption coefficient is concerned. Perforated panels with porous materials and 37 cm of air gaps in background have high absorption coefficients for all frequency bands, above 0.7 to 1.0. All measurements are performed in reverberation chamber, Mokpo National University, according to ISO 354 and ISO 3382.

  • PDF

Pool Combustion of Iso-Propanol Fuel including IPA and PCBs in different Type Vessels

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.102-108
    • /
    • 2006
  • On the refutation demanded for a control of various toxic substances. PCBs(poly chlorinated biphenyl) has a fatal poisonous matter in the ecosystem and the environmental pollution as it Is a kind of stable chemical substance. Especially, the gross Product of PCBs is estimated at about one million tonnage all over the world. However it is kept on storing in untreated state, then has a deterioration by the Prolonged storage and a risk of overflowing. Therefore, this research examined the fundamental characteristics of combustion and emission for the target of using the IPA (iso-propyl alcohol) solution as a part of PCBs control. IPA was filled to three kinds of Vessel, i.e. Vessel I, II, and III, and then was investigated as follows combustion shape, flame temperature. mass burning velocity, and PM(Particulate matter). A radial thermometer and a C-A thermocouple measured the flame temperature, and the optical extinction method by using He-Ne laser and the filter weight method used in the PM measurement. As a result, with an increasing of L/S ratio, the flame length become shorter and the burning velocity is more rapid, but the particulate matters is higher. It is supposed that the air flow rate is high on Vessel. and then the combustion is Promoted in the surface area of the upstream zone. The future works plan to investigate the characteristics with an using of the mixing of IPA and PCBs

Mechanical Properties and Biodegradability of HDPE/TPS Blends (HDPE/TPS블렌드의 물성 및 생분해도)

  • 이상일;홍경민;서석훈;신용섭;김봉식;신부영
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.145-151
    • /
    • 2002
  • Thermoplastic starch(TPS) was prepared from mixing starch and glycerol by twin extruder. The blends were then prepared from high density polyethylene(HDPE) and TPS. Mechanical properties, thermal properties, and morphology of the blends were investigated. Their biodegradability was also studied by using aerobic composting method(ISO14855). Tensile strength, modulus and elongation at break decreased as the content of TPS increased. In particular elongation at break decreased rapidly even at the lower content of TPS. The melting temperatures of the blends were not changed, which showed that HDPE and TPS were immiscible. The morphology of the fractured surface of blend films was investigated by scanning electron microscopy(SEM). It was found that phases were separated. After composting for 45days, the biodegradability of the blends increased as the content of TPS increased.