• 제목/요약/키워드: Irrigation system

검색결과 722건 처리시간 0.033초

The use of auxiliary devices during irrigation to increase the cleaning ability of a chelating agent

  • Prado, Marina Carvalho;Leal, Fernanda;Simao, Renata Antoun;Gusman, Heloisa;do Prado, Maira
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.105-110
    • /
    • 2017
  • Objectives: This study investigated the cleaning ability of ultrasonically activated irrigation (UAI) and a novel activation system with reciprocating motion (EC, EasyClean, Easy Equipamentos $Odontol\acute{o}gicos$) when used with a relatively new chelating agent (QMix, Dentsply). In addition, the effect of QMix solution when used for a shorter (1 minute) and a longer application time (3 minutes) was investigated. Materials and Methods: Fifty permanent human teeth were prepared with K3 rotary system and 6% sodium hypochlorite. Samples were randomly assigned to five groups (n = 10) according to the final irrigation protocol: G1, negative control (distilled water); G2, positive control (QMix 1 minute); G3, QMix 1 minute/UAI; G4, QMix 1 minute/EC; G5, QMix 3 minutes. Subsequently the teeth were prepared and three photomicrographs were obtained in each root third of root walls, by scanning electron microscopy. Two blinded and pre-calibrated examiners evaluated the images using a four-category scoring system. Data were statistically analyzed using Kruskal-Wallis and Dunn tests (p < 0.05). Results: There were differences among groups (p < 0.05). UAI showed better cleaning ability than EC (p < 0.05). There were improvements when QMix was used with auxiliary devices in comparison with conventional irrigation (p < 0.05). Conventional irrigation for 3 minutes presented significantly better results than its use for 1 minute (p < 0.05). Conclusions: QMix should be used for 1 minute when it is used with UAI, since this final irrigation protocol showed the best performance and also allowed clinical optimization of this procedure.

밭작물 가뭄피해 경감을 위한 소류천 유출수 저수 시스템 개발 (Development of a Long-slope Water Harvesting System in Natural Channel for Drought Mitigation in Upland)

  • 김영진;최용훈;이상봉;김민영;전종길
    • 한국농공학회논문집
    • /
    • 제62권6호
    • /
    • pp.111-118
    • /
    • 2020
  • This study developed a rainwater harvesting system for the irrigation of upland on sloping area. The assessment of water supply capacity was evaluated in farm field experience. This system consists of a water catchment device and a collapsible storage tank. The water catchment device was designed to collect runoff water in natural channel of 500 mm width into a pipe of 50 mm inner diameter. The device has funnel-shaped plan and cross-section of square. The storage capacity of the collapsible water tank was caculated to meet the water demand for irrigation in 30 a cultivated land for 10-year frequancy drought. The tank has a cuboid shape with a capacity of 30 ㎥, 5 m in width and length, 1.2 m in height. This system can supply 92% of the water required for drop irrigation of red pepper and 88% of the water required for drop irrigation of onions in 30 a cultivation land during the month of May and June. In the case of 16-dry days of 10-years frequency, this system is capable to irrigate 100% of required water for red pepper and onion, 76.7% of required water for Omija (Schisandra chinensis), and 51.5% of required water for autumn kimchi cabbage.

대형 수이젝터를 이용한 다목적댐 관개용수 펌핑시스템에 관한 연구 (A study on the irrigation water pumping system of multipurpose dams by the large water ejector)

  • 윤석훈;오철;손근홍;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.73-80
    • /
    • 1994
  • The water ejector is a low pressure high flow rate volumetric pump. It utilize the energy of a low mass flow, high velocity stream to induce a large mass flow, low velocity stream. In addition, it has a very good resistances to cavitation compared to the other type of pumps, and the maintenance cost is practically nil. There has been enormous energy loss to supply the upper part water of dam which has large potential energy as mere irrigation water in domestic multipurpose dam. The new type of energy saving system which developed through the present study can economizes over 950,000 kWh per year by mixing the upper part water of dam with the waste water by the large water ejector. This paper estimates the economical efficiency of the new type of irrigation water pumping system, and further more, represents the change of performance characteristics of large water ejector, which was adapted to this system, according to the fluctuation of upper water level that seasonally changes.

  • PDF

관개용수 공급체계 변경을 통한 하천의 수질개선 (Water Quality Improvement in the River through Reformation of Irrigation Water Supply Systems)

  • 이광야;김해도;이종남;박종훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.540-545
    • /
    • 2006
  • The objective of the study is to assess the water quality improvement resulted from the rearrangement of the irrigation water supply systems at Mankyeong River and Ansung Chun basin. There is a mixed type of watershed composed of urban and rural areas in the region. The water intake facilities for agricultural use such as reservoir, weir and pumping station are generally located at upstream river where the water quality maintains relatively clean. However, this study focuses on moving the water intake to downstream and rearranging the irrigation water supply system, then investigating how effective they are for water quality improvement in the river. When the water intake is moved downstream, the stream flow is increased as much as the amount of irrigation water that is to be taken upstream. The augmented flow which is frequently referred to as environmental flow can function as dilution water for improving the quality of polluted water that is originated from the wastewater in tributaries.

  • PDF

양액재배 급액제어모델 개발에 관한 기초연구 (A Fundamental Study on the Development of Irrigation Control Model in Soilless Culture)

  • 남상운
    • 한국농공학회지
    • /
    • 제41권2호
    • /
    • pp.37-43
    • /
    • 1999
  • This study was conducted to develop the simple and convenient irrigation control model which can maintain the appropriate rates of irrigation and drainage of nutrient solution according to the enviornmental conditions and growth stages in soilless culture of cucumber. In order to obtain fundamental data for development of the model, investigation of the actual state of soilless culture practices was carried out. Most irrigatioin systems of soillness culture were controlled by the time colock. Evapotranspiration of cucumber in soilness culture was investigated and correlations with environmental conditions were analyzed , and its estimating model was developed. In order to develop the irrigation system which can control the amount of nutrient solution applied according to seasons, weather conditions, and growth stages, a irrigation clock control was developed. Applicability of the model was tested by simulation. Drainage rates of nutrient solution controlled by conventional time clock, integrated solar radiation, and the developed model were 61% , 20%, and 32% , respectively in cucumber perlite culture.

  • PDF

부족조절관개와 실용상의 문제점 (Regulated Deficit Irrigation and Its Several Problemsin Practical Use)

  • Cai, Huanjie;Hang, Shazhong
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.30-40
    • /
    • 1999
  • 부족 (또는 적자) 조절관개는 용수절약 및 작물수량 증수를 위한 주요 방법중의 하나이다. 부족조절관개는 작물과 물의 관계에 근거를 두고 있다. 부족조절관개의 이론은 Shaanxi 및 Gansu 성에서의 실험자료을 이용하여 분석되었다. 부족조절관래에서의 실용상의 문제점은 ; 작물-물관계의 불확실성, 부족조절관개에서의 적정 생육기와 물부족의 정도, 관개조직과 기술에 대한 부족조절관개의 필요조건등이다.

  • PDF

분무경 시스템에서 팔레놉시스 유묘 생육에 적합한 분무간격 (Optimum Irrigation Interval for the Growth of Phalaenopsis Hybrid Seedling in the Aeroponic System)

  • 이동수;권오근;이용범;예병우;이영란
    • 생물환경조절학회지
    • /
    • 제19권4호
    • /
    • pp.234-239
    • /
    • 2010
  • 분무경시스템에서 분무간격과 분무시간은 식물의 생육어l 필요한 양분과 수분을 공급하기 위한 중요한 요소들이다. 이 실험은 분무경에서 분무간격이 팔레놉시스 유묘의 생육에 미치는 영향에 대하여 알아보고자 수행되었다. 배지 없이 뿌리가 나출된 생체중 16g 크기의 유묘를 사용하였다. 분무간격은 각각 10, 20, 30, 40, 50분 간격이었으며, 분무시간은 10분이었다. 총생체중, 총건물중, 분지된 뿌리수와 상대생장률은 20분과 30분 간격에서 10분, 40분, 50분 간격보다 높았다. 특히, 뿌리의 생체중은 30분 간격에서 기장 높았다. 엽장은 30분 간격에서 길었으나, 엽폭은 처리간 차이가 없었다. 10분 간격 처리에서 유묘 한 개체가 30일간 소비한 물량은 0.71L였으며, 분무간격이 증가함에 따라 그 양은 감소하였다. 15일간 소비된 양분은 칼륨이외에는 처리간 차이가 없었으며, 칼륨은 30분 간격에서 가장 많이 흡수되었다. 결과를 요약하면, 분무경 시스템에서 팔레놉시스 유묘 생산을 위한 적정 분무간격은 30분이었다.

An Optimal Design of Paddy Irrigation Water Distribution System

  • Ahn, Tae-Jin;Park, Jung-Eung
    • Korean Journal of Hydrosciences
    • /
    • 제6권
    • /
    • pp.107-118
    • /
    • 1995
  • The water distribution system problem consists of finding a minimum cost system design subject to hydraulic and operation constraints. The design of new branchin network in a paddy irrigation system is presented here. The program based on the linear programming formulation is aimed at finding the optimal economical combination of two main factors : the capital cost of pipe network and the energy cost. Two loading conditions and booster pumps for design of pipe network are considered to obtain the least cost design.

  • PDF

Climate change impact assessment of agricultural reservoir using system dynamics model: focus on Seongju reservoir

  • Choi, Eunhyuk
    • 농업과학연구
    • /
    • 제48권2호
    • /
    • pp.311-331
    • /
    • 2021
  • Climate change with extreme hydrological events has become a significant concern for agricultural water systems. Climate change affects not only irrigation availability but also agricultural water requirement. In response, adaptation strategies with soft and hard options have been considered to mitigate the impacts from climate change. However, their implementation has become progressively challenging and complex due to the interconnected impacts of climate change with socio-economic change in agricultural circumstances, and this can generate more uncertainty and complexity in the adaptive management of the agricultural water systems. This study was carried out for the agricultural water supply system in Seongju dam watershed in Seonju-gun, Gyeongbuk in South Korea. The first step is to identify system disturbances. Climate variation and socio-economic components with historical and forecast data were investigated Then, as the second step, problematic trends of the critical performance were identified for the historical and future climate scenarios. As the third step, a system structure was built with a dynamic hypothesis (causal loop diagram) to understand Seongju water system features and interactions with multiple feedbacks across system components in water, agriculture, and socio-economic sectors related to the case study water system. Then, as the fourth step, a mathematical SD (system dynamics) model was developed based on the dynamic hypothesis, including sub-models related to dam reservoir, irrigation channel, irrigation demand, farming income, and labor force, and the fidelity of the SD model to the Seongju water system was checked.

Outcomes of the GentleWave system on root canal treatment: a narrative review

  • Hernan Coaguila-Llerena;Eduarda Gaeta;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.11.1-11.11
    • /
    • 2022
  • This study aimed to describe the outcomes of the GentleWave system (GW) (Sonendo) on root canal treatment. Published articles were collected from scientific databases (MEDLINE/PubMed platform, Web of Science, Scopus, Science Direct and Embase). A total of 24 studies were collected from August/2014 to July/2021, 20 in vitro and 4 clinical. GW System was not associated with extrusion of the irrigant, promoted faster organic dissolution than conventional syringe irrigation (CSI), passive ultrasonic irrigation (PUI) continuous ultrasonic irrigation (CUI) and EndoVac, reduced more bacterial DNA and biofilm than PUI and CUI, promoted higher penetration of sodium hypochlorite into dentinal tubules than PUI and CUI in vitro, and removed more intracanal medication than CSI and PUI. GW was able to remove pulp tissue and calcifications. Moreover, its ability to remove hard-tissue debris and smear layer was better than that of CSI, and its ability to remove root canal obturation residues was lower or similar to that of PUI, and similar to that of CSI and EndoVac. Regarding root canal obturation of minimally instrumented molar canals, GW was associated with high-quality obturation. Clinically, the success rate of endodontic treatment using GW was 97.3%, and the short-term postoperative pain in the GW group was not different from CSI. Further research, mainly clinical, is needed to establish whether GW has any advantages over other available irrigation methods.