• Title/Summary/Keyword: Irradiation Ratio

검색결과 512건 처리시간 0.031초

미세먼지 농도가 직산분리 모델의 신뢰성에 미치는 영향에 관한 연구 (A Study on the Effect of Particulate Matter Concentration on the Reliability of Decomposition Model)

  • 이상혁;이경수
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.55-67
    • /
    • 2019
  • Recently, as the amount of particulate matter blowing from China increases, the domestic air environment is rapidly deteriorating. This pollution of the atmosphere greatly affects the light energy reaching the ground. Particularly, since the light enters the solar cell module in various forms, the amount of input energy of the solar power generation system may be changed depending on the ratio of direct beam irradiation and diffused horizontal irradiation. In this paper, we analyze how the ratio of direct beam component and diffused component on global horizontal irradiation varies with the atmospheric conditions. In addition, the reliability of the regression equation, designed to decompose the global horizontal irradiation into horizontal direct beam irradiation and diffused horizontal irradiation, was verified according to the level of air pollution. So, we derive the most suitable decomposition model for use in domestic climatic conditions in Korea by comparing the ratio of direct and diffuse component on the horizontal which is calculated with Perez model and Watanabe model using the meteorological weather data observed for 14 months. Finally, to reduce the error of the transposition result, we verified the reliability of the decomposition which depends on the atmospheric environment.

방사선조사와 온열요법이 백서신에 미치는 조직 변화에 관한 실험적 연구 (An Experimental Study on the Effects of Hyperthermia and Irradiation on the Rat's Kidney)

  • 유명희;이경자;이정식
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.157-169
    • /
    • 1989
  • Radiological and clinical evidences indicate that hyperthermia combined with irradiation produce a significant improvement in therapeutic effect of cancer The experiences obtained from 90 rats' kidney A single dose of irradiation ranged from 6Gy, 8Gy and 10Gy was delivered on the rat's kidney. The combined therapy group had the same irradiation after hyperthermia at $42\~44^{\circ}C$ for 30 minutes. Microscopic examination and calculation of thermal enhancement ratio were carried out, and the results were as follows: 1. In the group of hyperthermia alone, there were moderate glomerular congestion and mild tubular degeneration on light microscopic examination. 2. In the group of irradiation alone, tubular degeneration was noted in 6Gy irradiation and its severity was increased along with radiation dose. 3. In the group of hyperthermia combined with irradiation, tubular degeneration and necrosis were appeared in 6Gy and 10Gy irradiation, respectively. 4. On electron microscopic examination, proximal convoluted tubular and glomerular changes in irradiation group were similar to that of combined with hyperthermia, and its severity was increased along with observation periods. 5. Thermal enhancement ratio (TER) was 1.0 after evaluation of histipathologic changes in rat's kidney, with combination therapy.

  • PDF

Improvement of Device Characteristic on Solution-Processed InGaZnO Thin-Film-Transistor (TFTs) using Microwave Irradiation

  • Moon, Sung-Wan;Cho, Won-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.249-254
    • /
    • 2015
  • Solution-derived amorphous indium-gallium-zinc oxide (a-IGZO) thin-film-transistor (TFTs) were developed using a microwave irradiation treatment at low process temperature below $300^{\circ}C$. Compared to conventional furnace-annealing, the a-IGZO TFTs annealed by microwave irradiation exhibited better electrical characteristics in terms of field effect mobility, SS, and on/off current ratio, although the annealing temperature of microwave irradiation is much lower than that of furnace annealing. The microwave irradiated TFTs showed a smaller $V_{th}$ shift under the positive gate bias stress (PGBS) and negative gate bias stress (NGBS) tests owing to a lower ratio of oxygen vacancies, surface absorbed oxygen molecules, and reduced interface trapping in a-IGZO. Therefore, microwave irradiation is very promising to low-temperature process.

Evaluation of climate change on the rice productivity in South Korea using crop growth simulation model

  • Lee, Chung-Kuen;Kim, JunHwan;Shon, Jiyoung;Yang, Won-Ha
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2011년도 학술발표회
    • /
    • pp.16-18
    • /
    • 2011
  • Evaluation of climate change on the rice productivity was conducted using crop growth simulation model, where Odae, Hwaseong, Ilpum were used as a representative cultivar of early, medium, and medium-late rice maturity type, respectively, and climate change scenario 'A1B' was applied to weather data for future climate change at 57sites. When cropping season was fixed, rice yield decreased by 4~35% as climate change which was caused by poor filled grain ratio with high temperature and low irradiation during grain-filling. When cropping season was changed, rice yield decreased by only 0~5% as climate change which was caused poor filled grain ratio with low irradiation during grain-filling period. However, this irradiation decline was less than when cropping season was fixed. Therefore, we need to develop rice cultivars resistant to low irradiation which can maintain high filled grain ratio under poor irradiation condition, and late maturity rice cultivars whose growing period is longer than the present medium-late maturity type.

  • PDF

태양광 시스템의 계절별 일사량과 전력량 (Irradiation and Power Analysis According to Seasons)

  • 이영;정종철;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.220-220
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than $800[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study. the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

태양광 발전시스템의 계절별 일사량과 전력량 분석 (Analysis of Irradiation and Power per Each Seasons of Photovoltaic Systems)

  • 김석곤;황준원;이영;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.43-45
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

Studies on the Chromatin Isolated from the Organs of Animals Received Whole-body X-ray Irradiation

  • Han, Su Nam
    • 대한수의학회지
    • /
    • 제7권2호
    • /
    • pp.13-18
    • /
    • 1967
  • 1. Within experimental chromatin, the total protein: DNA ratio did not vary in the same organs of control and irradiated rats. However, the amount of RNA and total protein associated with the DNA varied considerably among the different types of chromatin. In particular, the content of chromatin was the control tissue. RNA and total protein ratio of chromatins from brtain, liver, testis and spleen declined with experimental I organs. 2. There was the same quantitative relationship between the amount of RNA and the amount of histone-protein associated with DNA in chromatin. 3. RNA: DNA ratio of chromatin showed 1.5-2 times increas in the irradiated organs except brain. However, RNA: DNA ratio was decreased in chromatin by irradiation. 4. Histone-protein:residual protein ratio was greatly varied among the organs. However, the effect was not found by irradiation. 5. Priming activity of chromatin showed a higher value in testis and the activity was greater in organs with higher metabolic activity: 6. Inhibition of Actinomycin D is observable in chromatin from testis, liver, spleen and brain declined without relationship between irradiated and non-irradiated conditions. Ammonium sulfate showed increased priming activity by the electrostatic dissociation of DNA and histone in chromatin on the stimulation depending on property of chromatins. 7. It is suggested that the results support a proposal that testis and spleen of highly sensitive to irradiation should an increase in the priming activity whereas brain and liver of lower sensitivity decreased in the activity.

  • PDF

Effect of irradiation temperature on the nanoindentation behavior of P92 steel with thermomechanical treatment

  • Huang, Xi;Shen, Yinzhong;Li, Qingshan;Li, Xiaoyan;Zhan, Zixiong;Li, Guang;Li, Zhenhe
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2408-2417
    • /
    • 2022
  • The nanoindentation behavior of P92 steel with thermomechanical treatment under 3.5 MeV Fe13+ ion irradiation at room temperature, 400 and 700 ℃ was investigated. Pop-in behavior is observed for all the samples with and without irradiation at room temperature, while the temperature dependence of pop-in behavior is only observed in irradiated samples. The average load and penetration depth at the onset of pop-in increase as the irradiation temperature increases, in line with the results of the maximum shear stress. Irradiation induced hardening is exhibited for all irradiated samples, but there is a significant reduction in the hardness of sample irradiated at 700 ℃ in comparison to the samples irradiated at room temperature and 400 ℃. The ratio of hardness to elastic modulus for all samples decreases with increasing penetration depth except for samples at 700 ℃. With the increasing of irradiation temperature, the ratio of the irreversible work to the total work gradually decreases. In contrast, it increases for samples without irradiation.

살균조건 및 UV-C 조사가 느타리버섯 병재배 오염율 감소에 미치는 영향 (The effect of sterilization condition and UV-C irradiation on the reduction of contamination rate for oyster mushroom bottle culture)

  • 백일선;지정현;정윤경;김정한;임재욱
    • 한국버섯학회지
    • /
    • 제13권3호
    • /
    • pp.256-261
    • /
    • 2015
  • 병재배 느타리버섯 재배과정중 발생되는 유해균 감소를 위한 적합 배지 살균조건과 UV-C 조사결과는 다음과 같다. 살균조건에 따른 오염율 및 전력소비량을 측정한 결과, $121^{\circ}C$에서 90분 살균시 오염율 0%, 전력소비량 4.1 kwh로 가장 낮게 조사되었다. 살균 후 배지 미생물상은 $121^{\circ}C$에서 90분, $109^{\circ}C$에서 2, 4, 6시간, $105^{\circ}C$에서 6시간, $101^{\circ}C$에서 6시간 살균시 버섯유해 곰팡이인 Trichoderma sp.가 검출되지 않았다. 또한, 버섯재배사의 냉각실과 접종실에 UV-C 처리에 의한 미생물의 사멸율을 조사한 결과, $56m^3$의 규모에서 40w짜리 UV-C를 6시간 조사했을 때 세균(Staphylococcus sp.) 사멸율은 99.9%로 거의 검출되지 않았다. 푸른곰팡이류중 가장 큰 오염원인 Trichoderma sp.와 Penicillium sp. 도 UV-C 6시간 조사 시 99.9% 사멸되었고, Cladosporium sp.는 동일 조건에서 90.9% 사멸되었으며 UV-C 12시간 조사시 94.9%의 사멸율을 보였다. 따라서 멸균 조건에 따른 오염율, 전력소비량, 미생물상 등을 종합해볼 때 $121^{\circ}C$에서 90분 고압살균하는 방법이 병재배에서는 적합하다고 판단되었으며, 버섯배양시 발생되는 주요 유해균은 UV-C 6시간 이상 점등 처리시 사멸율이 높았다.

극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향 (The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body)

  • 신한기;이태규;전재윤;김주승;강종호
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.