• Title/Summary/Keyword: Irradiation Dose

검색결과 1,996건 처리시간 0.039초

림프구 미소핵 측정법을 이용한 원자력발전소 주변 소의 이상산에 대한 방사선 생물학적 평가 (The Radiobiological Evaluation on Abnormal Delivery of Cattle around Nuclear Power Plant using Micronucleus Assay in Lymphocyte)

  • 김세라;김성호
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.364-368
    • /
    • 2003
  • Cytogenetic and hematological analysis was performed in peripheral blood from the cattle associated with abnormal delivery around nuclear power plant area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from cattle was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 Gy to 4 Gy from the bovine lymphocytes with in vitro irradiation. MN rates in live malformed calf, dams of malformed calves and other cattle living in the same barn from the regions around nuclear power plant, and cattle in control area were 9/1000, 10.8/1000, 13.3/1000 and 10.0/1000, respectively. There were no significant differences in MN frequencies and hematological values between the cattle associated with abnormal delivery around nuclear power plant area and those of control area. This study indicates that the congenital abnormalities near nuclear power plant seemed to be caused by other aetiology.

X-Ray Diffraction Measurements of Ion-Irradiated Graphite

  • Kim, Dae-Jong;Jang, Chang-Heui;Kim, In-Sup;Kim, Eung-Seon;Chi, Se-Hwan
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 춘계학술발표회
    • /
    • pp.411-412
    • /
    • 2005
  • There are some differences as a result of comparison between internal and external standard method. Thin-film XRD was used to measure the thin damaged layer by proton irradiation. Experiment was performed by external standard method to measure bulk sample accurately. A little changes of crystallite size and lattice parameter by small dose were observed. X-ray penetrates too deeply above damaged layer of graphite despite of small X-ray incident angle.

  • PDF

방사선 이리디움(Ir-192) 근접치료의 임상적 응용 (The Clinical Application of Radioactive Iridium (Ir-192) Brachytherapy)

  • 유성열
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.11-18
    • /
    • 1989
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related complication particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles in the field of brachytherapy. Total of 48 cases of head and neck and pelvic-perineal cancer patients had been treated with Ir-192 ribbons during last two years from October 1986 to September 1988, and the results were analyzed to assess the applicability of the fabricated sources. The conclusion is as follows; 1. Iridium implant resulted excellent tumor control effect in clinical application. 2. Iridium is superior than radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3. Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF

ESR Spectroscopy에 의한 전자선 조사 건조 채소의 검지와 흡수선량 예측 (Detection and Absorbed-Dose Estimation of Electron Beam-Irradiated Dried Vegetable Using ESR Spectroscopy)

  • 권중호;정형욱
    • 한국식품영양과학회지
    • /
    • 제28권4호
    • /
    • pp.882-885
    • /
    • 1999
  • Along with the increasing demands for food irradiation technology, proper detection methods for controlling irradiated foods are required. Dried vegetable(chunggyungchae), which is permitted to be irradiated in Korea, was subjected to a detection study by ESR spectroscopy. Pre established threshold value was successfully applicable to the detection of 50 coded unknown samples of dried clean vege tables, both nonirradiated and electron beam irradiated. Three calibration curves obtained from the samples irradiated at 2.5~15 kGy were not practically adopted to estimate actual absorbed doses ranging from 4 to 7 kGy.

  • PDF

질소이온 조사된 알루미늄 표면의 표면에너지 변화 및 증기응축 현상 관찰 (Observation of Surface Energy Variations and Condensate Behaviors on Nitrogen Ion Implanted Aluminum Surfaces)

  • 김기욱;정지환
    • 설비공학논문집
    • /
    • 제29권12호
    • /
    • pp.621-627
    • /
    • 2017
  • Nitrogen ion with various levels of dose and irradiation energy was irradiated on aluminum surfaces. Contact angle of surface was increased and surface color was changed by nitrogen ion implantation. During steam condensation experiment using nitrogen ion implanted specimen, dropwise condensation initially occurred on specimens. However, condensation mode eventually changed into filmwise condensation. The color of the surface was also changed from yellow-brown to silver-white. This change of surface color and condensation mode were results of hydrolysis reaction between condensate and nitrogen ion implanted on aluminum surfaces.

$Co^{60}$ 조사에 대한 A 급 절연채로의 방사선 손상에 관한 연구 (The Experimental Study of Co$^{60)$ Irradiaton Effect on Radiation Damage of A-Kind Insulator)

  • 지철근;김병수
    • 전기의세계
    • /
    • 제20권3호
    • /
    • pp.27-31
    • /
    • 1971
  • The main focus of this paper is on the study of the radiation effect upon the electrical property of a A-Kind insulator which is one of the organic insulators. The varnished cloth is so typical of the A-Kind insulators as to be selected for a sample. AC and Impluse voltage is applied to the variable Gamma ray irradiated dose samples with the constant time duration and the dielectric breakdown voltage are measured from the sample. The experimental data of the dielectric breakdown voltage are considerably decreased. The above conclusion is useful for the selection and application of the orgainc insulators under the irradiation effects.

  • PDF

EPR 케이블의 잔류전압에 미치는 방사선의 영향 (Effect of Radial Rays on Residual Voltage for EPR cable)

  • 이성일;류성림;김용추
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.518-521
    • /
    • 1999
  • This paper describes the properties of discharge current and the residual voltage for $^{60}$ C$_{0}$ -${\gamma}$ irradiated cables using in nuclear power generating station. As these properties related with $^{60}$ C$_{0}$ -${\gamma}$ -irradiatiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation. As the ratio of degradation increases, the residual voltage in the initial time range increases and the peak moves to the shorter time. Therefore, I know the degree of radiation degradation from the position of the peak.

  • PDF

자율 주행형 급수 배관 검사 (An automatic motorized feeder pipe inspection robot)

  • 최창환;전풍우;최용제;정승호;김승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.816-821
    • /
    • 2004
  • The outlet feeder pipe thinning in a PHWR (Pressured Heavy Water Reactor) is caused by high pressure steam flow inside the pipe, which is a well known degradation mechanism called FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends closed to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper develops an automatic feeder pipe inspection system that can minimize the irradiation dose by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix their body on the pipe and one extendable and retractable body connected the two gripper bodies to move forward and backward.

  • PDF

발코니형 BIPV시스템의 성능 분석 (Performance Analysis of Balcony BIPV System)

  • 김현일;강기환;소정훈;유권종;박경은;이길송;서승직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.208-209
    • /
    • 2007
  • Photovoltaic(PV) based electricity production is pollution-free at the local as well as the global level, it does not emit greenhouse gases, it dose not dip into finite file resources and it can be easily integrated into the urban environment, close to major consumption needs. So BIPV(Building-Integrated Photovoltaics) system have been increased around the world. This paper presents measuring and analyzing performance of balcony BIPV system which have been installed and monitoring. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. By the results, it is very important to develop optimal design for the balcony PV system.

  • PDF