• Title/Summary/Keyword: Iron Injection

Search Result 110, Processing Time 0.023 seconds

Pulverized coal injection system development to raise combustion efficiencies of a blast furnace (고로의 연소효율을 높이기 위한 미분탄 공급 시스템 개발)

  • An, Young-Jin;Kang, Pub-Sung;Kwak, Na-Soo;Choi, Gyung-Min;Lee, Min-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3163-3168
    • /
    • 2008
  • Pulverized coal (PC) has become an important auxiliary fuel in the iron and steel industry since the technique of pulverized coal injection (PCI) system was developed for iron making. Combustion efficiencies of pulverized coal in blowpipes and tuyeres under various operational are numerically predicted to recognize the performance with the locations of nozzles in a blast furnace. A variety of parameters including the pulverized coal quantities, oxygen amounts, inlet temperature of the tuyeres and mass flow rate of coal carrier gas are taken into consideration. Also In order to develop more efficient than existing coal injection system, this study applies a flame measurement system using a charge couple device (CCD) camera and frame grabber. And it has used algorithms of auto sampling from flame shape information and composed the device for location control of PCI. This study find to further improve the blast furnace performance by the control of PCI locations.

  • PDF

A New PIM Joining Process

  • Miura, Hideshi
    • Journal of Powder Materials
    • /
    • v.9 no.4
    • /
    • pp.203-210
    • /
    • 2002
  • A new PIM in-process joining technique has been developed for more complicated and functional PIM components by application of the exuded wax from the green compacts during solvent debinding step. At first, various stainless steels and iron compacts with rectangular shape were combined, and the joining behaviors and properties were investigated by shear and tensile test, and microscopic observation. Subsequently, perfect joined three pieces of thin and hollow compacts were obtained for the combination of same and different stainless steels, and it was difficult to join the iron and stainless steel compacts in hydrogen atmosphere because of the different starting temperature of shrinkage. However, pretty good joined iron and stainless steel compacts were obtained by consideration of particle size and vacuum atmosphere. Finally, for the combination of ferro-silicon and austenitic stainless steel compacts, high functionality (magnetic (1.60Tes1a) & non-magnetic) and perfect joint were obtained.

Study on the Renal Anemia - Experimental Study in Acute Renal Anemia - (신성빈혈(腎性貧血)에 관(關)한 연구(硏究) - 급성신성빈혈(急性腎性貧血)의 실험적(實驗的) 고찰(考察) -)

  • Yoon, Zo-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.2
    • /
    • pp.1-16
    • /
    • 1969
  • The double tracer study on erythrokinetics was carried out experimentally with radioactive iron ($^{59}Fe$) and chromium ($^{51}Cr$) in rabbits. The 0.1% canthalidin solution and 1% pot. perchlomate solution was given subcutaneously to 20 rabbits respectively. 3 and 6 days after injection, the blood chemistry, urine examination, ferrokinetics and apparent half survival time of RBC were ($^{51}Cr\;T\frac{1}{2}$)determined. Following were the results: 1) Red blood cell hematocrit and hemoglobin values were moderately reduced and B.U.N. and serum creatinine values were slight]y inercased in the canthalidin group, while B.U.N. and serum creatinine values were within normal limits in the pot. perchlomate group. Reticulocyte values were slight]y increased in the canthalidin group, while was normal range in the pot. perchlomate group. 2) Blood chemistry finding was not significant statistically in both experimental groups, but serum iron value was moderately reduced in both group. 3) Plasma volume was unchanged in both group, but red cell volume and whole blood volume were slightly reduced in both groups. 4) Results of ferrokinetics were as follows: i) The plasma iron disappearance rate was delayed in both groups. Plasma iron turnover rate, red cell iron utilization and red cell iron turnover rate were decreased in both groups, and then red cell iron turnover rate was more decreased than plasma iron turnover rate in both groups. Circulating red cell iron was slight]y increased in canthalidin group and red cell iron concentration was within normal range in both groups. ii) P.I.T.R.-R.C.I.T. value was moderately increased in the canthalidin group and slightly increased in the pot. perchlomate group. Reticulocyte index, red cell iron turnover index, plasma iron turnover index and effective erythropoiesis index were whole]y reduced in both groups. iii) The red cell life span was slightly shortened in the canthalidin group while was within normal range in pot. perchlomate group. The pathologic finding of renal biopsy of the canthalidin group shows a selective damage in glomerulus, while shows almost normal range or slight damage in tubules. And that of the pot. perchlomate group shows a selective damage in tubules with slight damage of glomerulus.

  • PDF

Field Study on Application of Reactive Zone Technology Using Zero-Valent Iron Nanoparticles for Remediation of TCE-Contaminated Groundwater (TCE 오염 지하수의 정화를 위한 나노영가철 기반 반응존 공법의 현장 적용성 연구)

  • Ahn, Jun-Young;Kim, Cheolyong;Hwang, Kyung-Yup;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.80-90
    • /
    • 2014
  • The laboratory and field studies were conducted to identify an optimal injection concentration of nanoscale zero-valent iron particles (NZVI) and to evaluate the applicability of NZVI-based reactive zone technology to the site contaminated with trichloroethylene (TCE) DNAPL (Dense Non-Aqueous Phase Liquid). The laboratory test found an optimal injection concentration of NZVI of 5 g/L that could remove more than 95% of 0.15 mM TCE within 20 days. Eleven test wells were installed at the aquifer that was mainly composed of alluvial and weathered soils at a strong oxic condition with dissolved oxygen concentration of 3.50 mg/L and oxidation-reduction potential of 301 mV. NZVI of total 30 kg were successfully injected using a centrifugal pump. After 60 days from the NZVI injection, 86.2% of the TCE initially present in the groundwater was removed and the mass of TCE removed was 405 g. Nonchlorinated products such as ethane and ethene were detected in the groundwater samples. Based on the increased chloride ion concentration at the site, the mass of TCE removed was estimated to be 1.52 kg. This implied the presence of DNAPL TCE which contributed to a higher estimate of TCE removal than that based on the TCE concentration change.

Scanning Electron Microscopic Study of Slime Formations in a Water Injection Station of Oil India Limited in Assam, India

  • Bhagobaty, Ranjan K.;Purohit, S.;Nihalani, M.C.
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.249-253
    • /
    • 2015
  • Microorganisms specifically groups of bacteria exhibiting physiological activities of production of acids are a major cause of concern because of their ability to induce corrosion in oil field pipelines and metal systems involved in water handling. Water Injection Stations as a means of secondary recovery from existing oil producing reservoirs, are often employed in most upstream oil and gas industries to ensure replenishment of voidage, maintenance of reservoir pressure and optimization of crude emulsion throughput. In the present study, scanning electron microscopy of macroscopic orange coloured slime formations sampled from leaking valves on the flow-lines of a Water Injection Stations of Oil India Limited revealed the presence of filamentous bacterial mats in association with diatoms. The species composition of the acidic slime formations from the sampled locations reveal the possible role of acid producing iron oxidizing bacteria (IOB) like Acidithiobacillus ferrooxidans in association with Gomphonema sp. in creating conditions for bio-corrosion.

Purification Siderophore from Vibrio mimicus ATCC 33653 and its Effect to Bacterial Pathogenecity (Vibrio mimicus ATCC 33653이 생산하는 Siderophore의 정제와 균의 병원성에 미치는 영향)

  • Park, Soo-Jung;Ju, Seong-A;Heo, Moon-Soo;Jung, Cho-Rok;Ju, Jin-Woo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.34 no.5
    • /
    • pp.461-470
    • /
    • 1999
  • Growth under conditions of iron-restriction and the production of siderophore was examined in Vibrio mimicus ATCC 33653. This strain grew and multiplied in the presence of the high-affinity iron chelators ethylenediamine-di (o-hydroxyphenylacetic acid). Chrome azurol S (CAS) agar and solution were used to detect the production of siderophore under these condition. Siderophore could be detected in the iron-restricted culture supernatants. The siderophore was extracted from iron-restricted culture supernatants by phenol-chloroform-ether method and purified by Dowex ion-exchange and Sephadex G-25 gel filtracton chromatography. The purified siderophore was confirmed by paper chromatography and HPLC. The Purified siderophore enhanced the growth of V. mimicus when the bacterium was grown in iron limited medium. Injection of both the siderohore and the bacteria to mice resulted in more rapid death than that of the only bacteria. However, the siderophore did not show lethality to mice and any toxicity to cell line like HeLa and U937.

  • PDF

Crystallographic and Magnetic Properties of Iron Oxide Nanoparticles for Applications in Biomedicine

  • Lee, Sang-Won;Woo, Kyoung-Ja;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.9 no.3
    • /
    • pp.83-85
    • /
    • 2004
  • Magnetic nanoparticles have been investigated for use as biomedical purposes for several years. For biomedical applications the use of particles that present superparamagnetic behavior at room temperature is preferred [1-4]. To control the magnetic materials by magnetic field is essential locate particle to the suitable destination on feeding by injection. In order to use them properly, the particles should be nano size. However there are many difficulties in applications, because there is lack of identifications in nano magnetic properties. In our studies, structural and magnetic properties of iron oxide nanoparticles were investigated by XRD, VSM, TEM, and Mossbauer spectroscopy. At 13 K, hyperfine fields of ${\gamma}-Fe_2O_3$ were 516 kOe and 490 kOe, that of $Fe_3O_4$ were 517 kOe and 482 kOe. The saturation magnetizations were 21.42 emu/g and 39.42 emu/g. The particle size of powders is 5~19 nm.

Redox Kinetics of Chromium(Ⅵ) in the Presence of Aquifer Materials Amended with Ferrous Iron

  • Hwang, Inseong;Batchelor, Bill
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.118-121
    • /
    • 2002
  • The kinetics and stoichiometry of the reduction of hexavalent chromium (Cr(Ⅵ)) with ferrous iron (Fe(II)) were examined in systems with and without aquifer solids. Cr(Ⅵ) reduction was rapid in the absence of solids, but demonstrated slower and more complex kinetics in the presence of aquifer solids. The aquifer solids removed Fe(II) from solution and a portion of the reducing capacity of Fe(II) was transferred to the aquifer solids. The solid phases were then able to continue to remove Cr(Ⅵ). This suggests in-situ treatment of Cr(Ⅵ) by Fe(II) injection would be feasible in the aquifer environment. In general, re-oxidation of reduced chromium by molecular oxygen was not observed in our systems over time periods of nearly one year.

  • PDF

The Structure and Standardization of Mold Base for Recycling (재활용을 위한 몰드베이스 구조 및 표준화)

  • 제덕근;한성렬;송준엽;정영득
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.225-231
    • /
    • 2003
  • The injection molding is a traditional manufacturing method that can make plastic parts by just one time in mold. Therefore, the injection molding has become one of a manufacturing method, which is widely applied in a producing of plastic products. Nowadays, to use of plastic parts has increased and plastic product-model using term has been shorten. By these reasons, using term of a injection mold has fast been reduced. These produced molds will be disused and leaved in a storage after a regular term to use it. These leaved molds are sometime sold as scrap iron. But, these molds have lots parts for recycling except special parts for example, cavities, cores and eject pins, etc. In this research, we investigated when the cavity and core of in injection mold would be changed, the injection mold could be recycled. We suggested the structures and standardizations for recycling of a moldbase. We also developed a program in which can be used when the recycling moldbase design in the Auto-CAD with the recycling standards. We called this program as the Recy-Mold. For the availability of the program and moldbase structure fur the recycling standards, we experimented a used mold for automobile lens, which was remanufactured by the recycling standard. The results of this test showed feasibility for the recycling mold.