POLARITY AND ION RECOMBINATION CORRECTION FACTORS OF A THIMBLE TYPE IONIZATION CHAMBER WITH DEPTH IN WATER IN THE MEGAVOLTAGE BEAMS

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.43-48
    • /
    • 2009
  • When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.

6MV 소형 x-선 beam 측정에 적합한 검출기의 조건에 관한 연구 (The study of detector condition proper to the measurement of 6MV small x-rays beam)

  • 유명진;도시홍
    • 센서학회지
    • /
    • 제8권3호
    • /
    • pp.219-225
    • /
    • 1999
  • 본 연구의 목적은 beam 지름이 12.5mm에서 40mm 까지의 소형 x-선에 대한 TMR, OAR, TSF를 전리함, 다이오드, 필름 및 TLD 등의 검출기로 측정하여 6MV 소형 x-선 beam 선량 측정에 적합한 검출기를 결정하였다. 가장 작은 beam인 지름 12.5mm beam의 TMR 값을 여러 가지 검출기로 측정한 결과 다이오드와 필름이 가장 우수하였으며 표준 TMR 값에 대한 오차 범위는 2% 이내였다. 그리고 이 다이오드와 필름은 OAR 측정 시공간 분해능이 뛰어났으며 이 두 검출기의 상대 비교에서 오차는 3% 이내였다. 이에 반해 전리함은 소형 beam의 TMR 및 OAR을 정밀하게 측정하는데 적합하지 않았다. beam 지름 12.5mm에서 40mm까지의 beam에 대한 TSF를 다이오드와 TLD로 측정한 결과 그 값은 $0.89{\sim}0.96$이었다. 그리고 beam 지름이 25mm 보다 크면 0.125cc 전리함 및 markus 전리함으로 측정한 TSF 값은 다이오드 및 TLD로 측정한 TSF 값과 잘 일치하였으며 그 오차 범위는 2% 이내였다.

  • PDF

RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구 (Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays)

  • 이정옥;정동혁;김부길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.205-212
    • /
    • 2009
  • 반응보정인자(h)는 고체팬텀에서 전리함의 반응을 물에서의 값으로 변환하기 위한 인자이다. RW3 고체 팬텀의 경우에 고에너지 X-선에 대한 반응보정인자는 선질과 깊이에 의존하는 것으로 알려져 있으나 조사면 크기와 SSD(Source to surface distance), 그리고 전리함 종류에 따른 의존성은 알려진 바가 없다. 본 연구에서는 알려진 의존성을 고찰하고 알려지지 않은 인자들에 대한 의존성을 조사하였다. 본 측정에서는 파머형전리함(FC65G, IBA, Germany)과 소형전리함(CC13, IBA, Germany)이 사용되었으며 대상 선질은 6 MV와 15 MV X-선이었다. 측정 결과 반응보정인자는 6 MV의 경우에 깊이 5 cm와 10 cm에서 각각 h = 1.015, 1.021, 그리고 15 MV의 경우에 깊이 5와 10 cm에서 각각 h = 1.024, 1.029로 나타났다. 결론적으로 반응보정인자는 선질과 깊이에는 의존하였지만 조사면 크기와 SSD에 따른 변화는 적었다. 전리함에 있어서 대상의 두 전리함에 대해서는 차이가 없었으나 다른 종류의 전리함에 대해서 추가적 연구가 필요하다고 생각한다. 본 결과는 RW3에서 전리함을 이용한 측정시 측정값의 분석에 활용될 수 있다.

  • PDF

전리함 반응 함수의 직접 측정과 이를 이용한 방사선의 실제선량 분포측정 (Direct Measurement of Chamber Response Function and Its Application to Radiation Dose Distribution Dosimetry)

  • 이상훈;조병철;김종훈;최은경;권수일;장혜숙;이병용
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.65-69
    • /
    • 1997
  • 목적 : 전리함의 크기로 인한 공간 분해능의 문제로 나타나는 전리함 반응함수를 제거하여 실제 선량분포를 얻고자 하였다. 대상 및 방법 : 내경 5mm, 6.4mm 등 2개의 서로 다른 크기를 갖는 전리함들과 다이오드, 필름의 반응함수를 구하고, 동일한 방사선 조사면$(10\times20cm^2)$의 선량분포 프로파일을 측정하여, 각각 deconvolution 기법으로 보정한 후, 보절된 격과가 일치하는지 비교하였다. 결과 : 원통형 전리함의 반응함수와 선량분포를 측정하였고, 측정한 선량분포에서 반응 함수의 효과를 deconvolution방법으로 제거하여 실제 선량분포를 찾아내었다. 사용한 에너지는 최대 광자선 에너지 4MV, 6MV, 15MV였으며, 전 에너지 영역에 걸쳐 보정 된 결과가 일치하는 방향으로 변화하였으며, 분해능 증가 효과가 있었다. 결론 : deconvolution 방법으로 전리함 반응 함수의 효과를 제거했을 때, 여러 측정기를 이용하여 측정한 선량 프로파일의 결과가 일치하는 경향을 볼 수 있어서 deconvolution 방법을 통해 얻은 선량 프로파일을 임상적으로 응용할 수 있음을 알았다.

  • PDF

Bilateral comparison of the absorbed dose to water in high energy X-ray beams between the KRISS and the NMIJ

  • Kim, In Jung;Kim, Byoung Chul;Yi, Chul-Young;Shimizu, Morihito;Morishita, Yuichiro;Saito, Norio
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1511-1516
    • /
    • 2020
  • The Korea Research Institute of Standards and Science (KRISS) established a new standard of the absorbed dose to water in LINAC X-ray beams. To confirm the equivalence of the new standard with other national metrology institutes (NMIs), a bilateral comparison study of the absorbed dose to water in high energy X-ray beams was performed between the KRISS and the National Metrology Institute of Japan (NMIJ). The comparison was made in-directly. Three transfer chambers were calibrated in the high energy X-ray beams by both laboratories and the calibration coefficients were compared. The average ratios of the calibration coefficients of the three transfer chambers obtained by the KRISS to those obtained by the NMIJ were 1.004, 1.006, 1.006, 1.007 for 6, 10, 15 and 18 MV X-ray beams, respectively. The calibration coefficients obtained at the KRISS were higher than those at the NMIJ but they were in good agreement within the expanded uncertainty of 1.0% (k = 2). The results of this study will be used as the evidence for the KRISS standard being comparable with those of other NMIs, temporarily, in the interim period up to finalizing a key comparison study, BIPM.RI(I)-K6 managed by the Consultative Committee for Ionizing Radiation.

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구 (Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.55-61
    • /
    • 2002
  • 본 연구는 제작된 방사선 측정시스템을 평가하기 위한 방법중의 하나인 유효측정점을 명확히 정하기 위하여 실행되었다. 일반적으로 원통형이나 두 전극간의 간격이 매우 작은 평행평판형 이온함의 경우 유효측정점은 잘 정의 되어있다. 그 정의에 의하면 그리 크지 않은 체적을 갖는 평행평판형 이온함의 유효측정점은 방사선이 입사되는 윗면의 바로 아래로 정의한다고 되어있다. 그러나 본 연구에서 제작한 이온함과 같이 두 전극간의 간격을 비교적 크게 할 경우 위의 정의는 더 이상 유효하지 않을 수도 있을 것으로 생각되어 평행평판형 이온함의 두 전극간의 간격을 3, 6, 10 mm로 하여 체적이 0.9, 1.9, 3.1 cc로 비교적 크게 한 경우에 그 유효측정점의 변화를 검토하고자 하였다. 실험은 의료용 선형가속기로부터 발생가능한 광자선 6, 10 MV와 전자선 6, 12 MeV에 대하여 시행되었으며, 방법은 이온함의 buildup의 두께를 증가시켜가면서 방사선의 측정선량이 최대가 되는 깊이를 조사하였다. 그 결과 광자선과 전자선의 경우 조사된 모든 에너지에 대하여 그 정도의 차이는 있으나 전반적으로 이온함의 체적이 커짐에 따라서 즉, 두 전극간의 간격이 멀어짐에 따라서 유효측정점이 이온함의 윗면에서부터 이온함의 중심 쪽으로 이동하는 경향을 보였다. 그 정도는 이온함 체적의 크기가 커질수록 더 크게 이동하는 양상을 보였다. 이와 같은 결과로 볼 때 평행평판형 이온함의 경우는 두 전극간의 간격이 어느 정도 큰 경우에는 유효측정점이 변하게 됨으로 이온함의 체적에 따라서 그 유효측정점을 조사할 필요가 있다고 생각된다.

  • PDF

Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

  • Coulon, Romain;Dumazert, Jonathan;Tith, Tola;Rohee, Emmanuel;Boudergui, Karim
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1489-1494
    • /
    • 2017
  • The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, and $LaBr_3:Ce$. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

Correlation Between Exposure Rate and Quasi-Effective Energy of Natural Radiation in Japan -TLD Application-

  • Nakajima, Toshiyuki
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.54-60
    • /
    • 1987
  • The quasi-exposure rate and the quasi-effective energy of the natural radiation in the field at 47 monitoring points around nuclear power plants have been studied with the pair filter thermoluminescence dosimeter system. The results of the six years observation showed that the relationship between the quasi-exposure rate $X_q$, and quasi-effective energy $E_q$ can be represented as a hyperbolic function: $X_q=A+C/(E_q-B)$, where the constants A and B correspond to the quasi-exposure rate of cosmic-rays and the minimum quasi-effective energy of natural radiation, respectively. Furthermore, the constant A is in close agreement with the values obtained by using ionization chambers and scintillation detectors. The constant B is approximately 0.68 MeV, closely corresponding to the mean energy of the photons emitted from natural uranium.

  • PDF

전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구 (Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2)

  • 김미영;이동주;문영민;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.178-184
    • /
    • 2015
  • 마커스 전리함은 치료용 전자선의 흡수선량 측정에 널리 사용되는 소형 평행 평판형 전리함이다. 특히 TRS-398 프로토콜에서는 $R_{50}<4.0g/cm^2$ (약 10 MeV 이하)에서 평행 평판형 전리함의 사용을 권고하고 있다. 그러나 TRS-398 프로토콜에서 $R_{50}<2.0g/cm^2$ (약 4 MeV 이하)에 대한 선질보정인자($k_{Q,Q_0}$)가 없어 낮은 에너지에 대한 선량측정이 필요한 경우에 마커스 전리함을 사용할 수 없다. 본 연구에서는 몬테칼로 계산(DOSRZnrc/EGSnrc)과 선량학적 계산을 이용하여 전자선 선질 $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, $5.0g/cm^2$에 대하여 마커스 전리함(PTW-M34045)에 대한 $k_{Q,Q_0}$를 결정하였다. 본 연구에서는 결정된 $k_{Q,Q_0}$에 대해 TRS-398 및 TG-51 프로토콜의 자료와 알려진 자료들을 이용하여 평가하였다.