• Title/Summary/Keyword: Ionic polymer composite

Search Result 114, Processing Time 0.024 seconds

Nanofiltration of Electrolytes with Charged Composite Membranes

  • Choi, J.H.;Yeom, C.K.;Lee, J.M.;Suh, D.S.
    • Membrane Journal
    • /
    • v.13 no.1
    • /
    • pp.29-36
    • /
    • 2003
  • A characterization of the permeation and separation using single salt solution was carried out with charged composite membranes. Various charged composite membranes were fabricated by blending an ionic polymer with a nonionic polymer in different ratios. In this study, sodium alginate, chitosan and poly(vinyl alcohol) were employed as anionic, cationic and nonionic polymers, respectively. The permeation and separation behaviors of the aqueous salt solutions have been investigated through the charged composite membranes with various charge densities. As the content of the ionic polymer increased in the membrane, the hydrophilicity of the membrane increased, and pure water flux and the solution flux increased correspondingly, indicating that the permeation performance through the membrane is determined mainly by its hydrophilicity. Electrostatic interaction between the charged membrane and ionic solute molecules, that is, Donnan exclusion, was observed to be attributed to salt rejection to a greater extent, and molecular sieve mechanism was effective for the separation of salts under a similar electrostatic circumstance of solutes.

Fabrication of Ionic Polymer-Metal Composite Actuator and Application to Moving Mechanism (이온성 고분자-금속 복합물 액추에이터의 제작 및 이동형 액추에이터에의 응용)

  • Lee, Seung-Ki;Lee, Sang-Jo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.112-120
    • /
    • 2003
  • The composite of ionic polymer and metal has been fabricated and used for actuators. Platinum is deposited by electroless plating method onto the both sides of ionic polymer where ac voltage is applied. This results in the bending motion of a beam type actuator. In this paper, the fabrication method of ionic polymer-metal composite has been explained and the moving mechanism has been fabricated and measured using the ionic polymer-metal composite actuator. The moving mechanism is wireless type and the power is supplied through the rail electrodes in base plate. The maximum speed of the moving mechanism was about 24cm/min.

Ionic Polymer-Metal Composite Actuator with Increased Air-Operating stability by Using Ionic Liquids

  • Lee, Jang-Yeol;Han, Man-Jae;Lee, Sung-Won;Park, Sun-Jin;Yoon, Bye-Ri;Jho, Jae-Young
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.246-246
    • /
    • 2006
  • Ionic polymer-metal composite (IPMC) soaked with various ionic liquids was prepared by using polystyrene sulfonic acid-grafted poly(vinylidene fluoride-co-hexafluoropropylene) as ion-exchange membrane (IEM). The prepared IPMCs were effectively deformed three times larger and actuated for 300 times longer than those of Nafion with water at the same applied conditions. The experimental results indicated than the increase in the bending capability can be caused by the increase in the improved properties of the IEMs and ionic liquids such as uptake content and ionic conductivity. And air-operating stability of the IPMCs is appreciably governed by various physical and electrochemical properties of soaked solvents in IEMs.

  • PDF

Investigation of Lithium Transference Number in PMMA Composite Polymer Electrolytes Using Monte Carlo (MC) Simulation and Recurrence Relation

  • Koh, Renwei Eric;Sun, Cha Chee;Yap, Yee Ling;Cheang, Pei Ling;You, Ah Heng
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.217-224
    • /
    • 2021
  • In this study, Monte Carlo (MC) simulation is conducted with recurrence relation to study the effect of SiO2 with different particle size and their roles in enhancing the ionic conductivity and lithium transference number of PMMA composite polymer electrolytes (CPEs). The MC simulated ionic conductivity is verified with the measurements from Electrochemical Impedance Spectroscopy (EIS). Then, the lithium transference number of CPEs is calculated using recurrence relation with the MC simulated current density and the reference transference number obtained. Incorporation of micron-size SiO2 (≤10 ㎛) fillers into the mixture improves the ionic conductivity from 8.60×10-5 S/cm to 2.35×10-4 S/cm. The improvement is also observed on the lithium transference number, where it increases from 0.088 to 0.3757. Furthermore, the addition of nano-sized SiO2 (≤12 nm) fillers further increases the ionic conductivity up towards 3.79×10-4 S/cm and lithium transference number of 0.4105. The large effective surface area of SiO2 fillers is responsible for the improvement in ionic conductivity and the transference number in PMMA composite polymer electrolytes.

Ionic Cluster Mimic Membranes Using Ionized Cyclodextrin

  • Won Jong-Ok;Yoo Ji-Young;Kang Moon-Sung;Kang Yong-Soo
    • Macromolecular Research
    • /
    • v.14 no.4
    • /
    • pp.449-455
    • /
    • 2006
  • Ionic cluster mimic, polymer electrolyte membranes were prepared using polymer composites of crosslinked poly(vinyl alcohol) (PVA) with sulfated-${\beta}$-cyclodextrins (${\beta}-CDSO_3H$) or phosphated-${\beta}$-cyclodextrins (${\beta}-CDPO(OH)_2$). When Nafion, developed for a fuel cell using low temperature, polymer electrolyte membranes, is used in a direct methanol fuel cell, it has a methanol crossover problem. The ionic inverted micellar structure formed by micro-segregation in Nafion, known as ionic cluster, is distorted in methanol aqueous solution, resulting in the significant transport of methanol through the membrane. While the ionic structure formed by the ionic sites in either ${\beta}-CDSO_3H$ or ${\beta}-CDPO(OH)_2$ in this composite membrane is maintained in methanol solution, it is expected to reduce methanol transport. Proton conductivity was found to increase in PVA membranes upon addition of ionized cyclodextrins. Methanol permeability through the PVA composite membrane containing cyclodextrins was lower than that of Nafion. It is thus concluded that the structure and fixation of ionic clusters are significant barriers to methanol crossover in direct methanol fuel cells.

Preparation, Characterizations and Conductivity of Composite Polymer Electrolytes Based on PEO-LiClO4 and Nano ZnO Filler

  • ElBellihi, Abdelhameed Ahmed;Bayoumy, Wafaa Abdallah;Masoud, Emad Mohamed;Mousa, Mahmoud Ahmed
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.2949-2954
    • /
    • 2012
  • Nano ZnO with an average size of 8 nm was prepared by thermal decomposition of zinc oxalate at $450^{\circ}C$. A series of based composite polymer electrolyte PEO-$LiClO_4$ and nano ZnO as a filler have been synthesized using solution cast technique, with varying the filler ratio systematically. XRD, DSC and FTIR studies have been conducted to investigate the structure and interaction of different groups in the composite polymer electrolyte. Effect of nano ZnO ceramic filler concentration on the structure of composites and their electrical properties (DC-conductivity, AC-conductivity, dielectric constant, dielectric loss and impedance) at different frequencies and temperatures was studied. Melting temperature ($T_m$) of PEO decreased with the addition of both $LiClO_4$ salt and nano ZnO filler due to increasing the amorphous state of polymer. All composite samples showed an ionic conductivity. The maximum room temperature ionic conductivity is found for $(ZnO)_{0.5}(PEO)_{12}(LiClO_4)$ composite sample. All the results are correlated and discussed.

Characteristics of composite membranes containing ionic liquid and acid for anhydrous high temperature PEFCs (무가습 고온 PEFC용 이온성 액체 및 산이 함유된 복합막의 특성)

  • Baek, Ji-Suk;Park, Jin-Soo;Park, Seung-Hee;Yang, Tae-Hyun;Park, Gu-Gon;Yim, Sung-Dae;Kim, Chang-Soo;Shul, Young-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.378-378
    • /
    • 2009
  • The ionic liquid-based sulfonated hydrocarbon composite membranes was prepared for use in anhydrous high temperature-polymer electrolyte fuel cells (HT-PEFCs). Ionic liquid behaves like water in the composite membranes under anhydrous condition. However the composite membranes show a low conductivity and high gas permeability as the content of ionic liquid increases due to its high viscosity and content of ionic liquid, respectively. Hence, in order to enhance the proton conductivity and to reduce the gas permeability of the composite membranes with low content of ionic liquids, the acid containing a common ion of ionic liquid was added to the composite membranes. The characterization of composite membranes was carried out using small-angle X-ray scattering (SAXS), thermogravimetric analyzer (TGA) and impedance spectroscopy. As a result, the composite membranes containing acid showed higher proton conductivity than those with no acid under the un-humidified condition due to a decrease in viscosity. In addition, the proton conductivity of composite membranes increased with increasing mole concentration of acid.

  • PDF

A study on composite membranes based on hydrocarbon polymers and ionic liquids for high temperature PEFCs (고온 PEFCs를 위한 탄화수소계열 고분자와 이온성 액체를 함유하는 복합막에 관한 연구)

  • Baek, Ji-Suk;Park, Jin-Soo;Kim, Kyung-Hyun;Moon, Gi-Young;Kim, Hye-Kyung;Choi, Young-Woo;Park, Go-Gun;Yang, Tae-Hyun;Kim, Chang-Soo;Shul, Young-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.147-148
    • /
    • 2009
  • The water-like ionic liquids have been widely used to enable the proton conduction in ionic liquid based membranes at high temperature and anhydrous PEFCs. In this study, we synthesized various kinds of composite membranes based on hydrocarbon polymers having good thermal and mechanical stabilities at high temperatures and ionic liquids. The composite membrane consisting of hydrocarbon polymer and ionic liquid was characterized by thermogravimetric analyzer (TGA) and impedance spectroscopy. Consequently the non-aqueous composite membranes of a variety of hydrocarbon polymer and ionic liquids have good conductivity and thermal stability at high temperature conditions.

  • PDF

A Review: All Solid-state Electroactive Polymer-based Tunable Lens (고체 전기활성 고분자 기반 가변 렌즈의 연구동향)

  • Shin, Eun-Jae;Ko, Hyun-U;Kim, Sang-Youn
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.41-48
    • /
    • 2021
  • In this paper, we review papers which report to the all solid-state electroactive polymer-based tunable lens. Since electroactive polymer-based tunable lenses change their focal length by responding to electric stimuli, it can be minimized the size and weight of optical modules. Thus, it has been received attention in the robot, mobile device and display industry. The all solid-state electroactive polymer-based tunable lenses can be classified into two categories depending on the classification of materials: ionic electroactive polymer-based lenses and non-ionic electroactive polymer-based lenses. Most of the ionic electroactive polymer-based tunable lenses are fabricated with ionic polymer-metal composite. So, the ionic electroactive polymer-based tunable lenses can be operated under low electric voltage. But small force, slow recovery time and environmental limitation for operation has been pointed to the disadvantage of the lenses. The non-ionic electroactive polymer-based tunable lenses are classified again into two categories: dielectric polymer-based tunable lenses and polyvinylchloride gel-based tunable lenses. The advantage of the dielectric polymer-based tunable lenses is fast response to electric stimuli. But the essential flexible electrodes degrade performance of the lens. Polyvinylchloride gel-based tunable lens has reported impressive performance without flexible electrodes.

Analysis of Mechanical Characteristics of ionic Polymer-Metal Composite Actuators Fabricated by Casting Method (캐스팅 방법에 의해 제작한 이온성 고분자-금속 복합체 액추에이터의 기계적 특성 분석)

  • 이승기;김병목;김병규;박정호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.144-151
    • /
    • 2003
  • IPMC(Ionic Polymer-Metal Composite) is promising candidate material for bio-related actuators mainly due to its biocompatibility and wet and soft properties. The widely used commercialized Nafion film has a few kinds of fixed thicknesses but more various film thicknesses are required for extensive applications. Especially for the enhanced force as an actuator, the thick film is essential. Various Nafion films with thickness of 0.4-1.2mm have been prepared by casting of liquid Nafion. Also, IPMC actuators using casted Nafion films have been fabricated and the basic mechanical properties such as stiffness, displacement and force were measured and analyzed. These results can be used for the optimized design of actuators for different applications.