• 제목/요약/키워드: Ionic composition

검색결과 210건 처리시간 0.026초

충주시 초미세먼지 (PM2.5)의 배출원 기여도 추정에 관한 연구 (Source Apportionment of Fine Particulate Matter (PM2.5) in the Chungju City)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.437-448
    • /
    • 2015
  • The purpose of this study is to present the source contribution of the fine particles ($PM_{2.5}$) in Chungju area using the CMB (chemical mass balance) method throughout the four seasons in Korea. The Chungju's annual average level of $PM_{2.5}$ was $48.2{\mu}g/m^3$, which exceeded two times higher than standard air quality. Among these particles, the soluble ionic compounds represent 54.2% of fine particle mass. Additionally, the OC concentration in Chungju stayed similar to other domestic cities, while the EC concentration decreased significantly compared to other domestic/international cities. The concentration of sulfur represented the highest composition (8%) among the fine particle compounds. According to the CMB results, the general trend of the $PM_{2.5}$ mass contributors was the following: secondary aerosols (50.5%: ammonium sulfate 26.5% and ammonium nitrate 24.0%) > gasoline vehicle (18.3%) > biomass burning (11.0%) > industrial boiler (6.0%) > diesel vehicles (4.4%). The contribution of the secondary aerosols was the main cause than others. This impact is assumed to be emitted from air pollutants of urban cities or neighbor countries such as China.

SMD-type Trimmer Condenser용 $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\}Ti_{1.02}O_3$ (Electrical Properties of $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\}Ti_{1.02}O_3$ for SMD-type Dielectric Trimmer Condenser)

  • 강동헌;차훈주;남기창;허준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.597-600
    • /
    • 2002
  • Electrical properties of $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\})Ti_{1.02}O_3$ ceramic were studied as a function of Sr/Ca ratio and Bi, Pb contents. Dielectric properties of specimens with different x, y, z values were explained in terms of ionic polarizability with Molecular Additionally Rules and Clausius-Mosotti equation. For the composition of $\{(Sr_{0.62}Ca_{0.38})_{0.90}Bi_{0.01}Pb_{0.09}\})Ti_{1.02}O_3$ and $\{(Sr_{0.62}Ca_{0.38})_{0.905}Bi_{0.015}Pb_{0.08}\})Ti_{1.02}O_3$, dielectric constant$({\varepsilon}_r)$, quality factor(Q) and temperature coefficient(TC) were 389, 3048, -1490 and 394, 1869, -1340 at 1MHz, respectively.

  • PDF

Nanofiltration of multi-ionic solutions: prediction of ions transport using the SEDE model

  • Cavaco Morao, A.I.;Szymczyk, A.;Fievet, P.;Brites Alves, A.M.
    • Membrane and Water Treatment
    • /
    • 제1권2호
    • /
    • pp.139-158
    • /
    • 2010
  • This work focuses on the application of nanofiltration (NF) to the concentration of a pharmaceutical product, Clavulanate ($CA^-$), from clarified fermentation broths, which show a complex composition with six main identified ions ($K^+$, $Cl^-$, ${NH_4}^+$, $H_2{PO_4}^-$, ${SO_4}^{2-}$ and $CA^-$), glucose and glycerol. The solutes transport through the NF membrane pores was investigated using the SEDE (Steric, Electric and Dielectric Exclusion) model. This model was applied to predict the rejection rates of the initial feed solution and the final concentrated solution (10-fold concentrated solution). The best results were achieved with a single fitted parameter, ${\varepsilon}_p$ (the dielectric constant of the solution inside pores) and considering that the membrane selectivity is governed by steric, electric (Donnan) and Born dielectric exclusion mechanisms. While the predicted intrinsic rejections of solutions comprising up to six ions and uncharged solutes were in good agreement with the experimental values, the deviations were much larger for the 10-fold concentrated solution.

Modeling of IPMC (Ionic Polymer-Metal Composite) Sensor to Effectively Detect the Bending Angles of a Body

  • Park, Ki-Won
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.375-381
    • /
    • 2011
  • Ionic polymer-metal composite(IPMC) consists of an ion conductive membrane plated by metallic electrodes on both surfaces. When it bends, a voltage is generated between two electrodes. Since IPMC is flexible and thin, it can be easily mounted on the various surfaces of a body. The present study investigates a sensor system using IPMC to effectively detect the bending angles applied on IPMC sensor. The paper evaluates several R and C circuit models that describe the physical composition of IPMC and selects the best model for the detection of angles. The circuit models implemented with a charge model describe the relationship between input bending angles and output voltages. The identification of R and C values was performed by minimizing the error between the real output voltages and the simulated output voltages from the circuit models of IPMC sensor. Then the output signal of a sensor was fed into the inverse model of the identified model to reproduce the bending angles. In order to support the validation of the model, the output voltages from an arbitrary bending motion were also applied to the selected inverse model, which successfully reproduced the arbitrary bending motion.

제주도 고산지역 입자특성 : 1994년 3월 11일 - 17일 측정결과 (Characteristics of particles at Kosan, Cheju Island: Intensive study results duting March 11 .sim. 17 1994)

  • 김용표;심상규;문길주;백남준;김성주;허철구;강창희
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.263-272
    • /
    • 1995
  • Characteristics of anbient at Korean, Cheju Island have been studied during the intensive field study period on March 11 .sim. 17, 1994 in collaboration with other research organizations from Korea and abroad. The particle size distribution was measured using an Electrical Aerosol Analyzer(EAA) and an Optical particle Counter(OPC). Fine particles(PM1 and PM3) have been collected by filter pack samplers and their ionic compositions have been analyzed. sampling errors inherent to the filter pack sampling method are discussed and the method to analyze those errors are presented. The rine mass concentrations of this study show very similar mass concentrations when Seoul is clear. This is somewhat surprising result, because the most of researchers believe that Kosan is one of the cleanest area in Korea. Bimodal volume size distributions with peak values around 0.1 .sim. 0.2.mu.m and 3.mu.m in particle dimeter were observed for most of the measurement period, particle mass loadings and ionic composition data show a large fraction of particles are from non-sea salt origins. Estimation of water content and acidity of particles based on measurement by a gas/particle equilibrium model, SCAPE, reveals that the pH values of particles are comparable to or lower than those estimated based on measurements in Los Angeles, U.S.A. during the SCAQS study. These findings with the meteorological conditions during the study period suggest that the particles collected during the period have originated from outside Cheju Island.

  • PDF

물, Dioxane-물 및 Ethanol-물의 混合溶媒에서의 Hydrogen Cupferrate의 酸解離常數의 決定 (Determination of Dissociation Constant of Hydrogen Cupferrate in Water, Dioxane-Water, and Ethanol-Water Solution)

  • 김시중;윤창주;장인순
    • 대한화학회지
    • /
    • 제10권3호
    • /
    • pp.114-118
    • /
    • 1966
  • The glass electrode was empirically calibrated in dioxane-and ethanol-water mixed solvents, by means of which the pH-meter reading could be converted to stoichiometric hydrogen ion concentration. By the potentiometric titration method, the thermodynamic dissociation constants of hydrogen cupferrate (HCup) with variations of ionic concentration in aqueous solution were determined, and by the extrapolation of the constants the new thermodynamic $pK_a$ value, 3.980${\pm}$0.006, at zero ional concentration was obtained. The thermodynamic dissociation constants of HCup in dioxane-and ethanol-water solution were also potentiometrically determined with the changes in composition of organic solvents at 0.01 and 0.05 of the ionic strength(${mu}$) and 25 $^{\circ}C$. The empirical formula of the constants with mole fraction(n) of the organic solvent are as follow: Dioxane-water solution. $pK_a$= 12.96n + 4.10 at ${\mu}$ = 0.01, n = 0.0228∼0.171 $pK_a$= 12.05n + 4.23 at ${\mu}$ = 0.05, n= 0.0228∼0.171 Ethanol-water solution, $pK_a$= 4.0ln + 4.26 at ${\mu}$= 0.01, n= 0.0395∼0.262 $pK_a$= 3.83n + 4.34 at ${\mu}$= 0.05, n= 0.0395∼0.262

  • PDF

혼합물설계법에 의한 Li2O-TeO2-ZnO 유리의 물성에 대한 조성의 가성성인자 분석 (Additivity Factors Analysis of Compositions in Li2O-TeO2-ZnO Glass System Determined from Mixture Design)

  • 정영준;이규호;김태호;김영석;나영훈;류봉기
    • 한국재료학회지
    • /
    • 제18권11호
    • /
    • pp.617-622
    • /
    • 2008
  • In this study, the additivity factors of compositions to density and glass transition point ($T_g$) in a $xLi_2O-(1-x)[(1-y)TeO_2-yZnO]$ (0$T_g$ was discussed. As a method for predicting the relation between glass structure and ionic conductivity, density was measured by the Archimedes method. The glass transition point was analyzed to predict the relation between ionic conductivity and the bonding energy between alkali ions and non-bridge oxygen (NBO). The relation equations showing the additivity factor of each composition to the two properties are as follows: Density(g/$cm^3$) = $2.441x_1\;+\;5.559x_2\;+\;4.863x_3\;T_g(^{\circ}C)$ = $319x_1\;+\;247x_2\;+\;609x_3\;-\;1950x_1x_3$ ($x_1$ : fraction of $Li_2O$, $x_2$ : fraction of $TeO_2$, $x_3$ : fraction of ZnO) The density decreased as $Li_2O$ content increased. This was attributed to change of the $TeO_2$ structure. From this structural result, the electric conductivity of the glass samples was predicted following the ionic conduction mechanism. Finally, it is expected that electric conductivity will increase as the activation energy for ion movement decreases.

2009~2010년 제주지역 강우의 오염 특성 연구 (Pollution Characteristics of Rainwater at Jeju Island during 2009~2010)

  • 김기주;부준오;김원형;이윤상;현동림;강창희
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.818-829
    • /
    • 2013
  • The collection of rainwater samples was made at Jeju area during 2009~2010, and the major ionic species were analyzed. In the comparison of ion balance, conductivity, and acid fraction for the validation of analytical data, the correlation coefficients showed a good linear relationship within the range of 0.966~0.990. The volume-weighted mean pH and electric conductivity were 4.9 and $17.8{\mu}S/cm$, respectively, at the Jeju area. The volume-weighted mean concentrations of ionic species in rainwater were in the order of $Cl^-$ > $Na^+$ > $nss-SO_4{^{2-}}$ > $NH_4{^+}$ > $NO_3{^-}$ > $Mg^{2+}$ > $H^+$ > $nss-Ca^{2+}$ > $HCOO^-$ > $K^+$ > $PO_4{^{3-}}$ > $CH_3COO^-$ > $NO_2{^-}$ > $F^-$ > $HCO_3{^-}$ > $CH_3SO_3{^-}$. The ionic strength of rainwater was $0.26{\pm}0.21$ mM during the study period. The composition ratios of ionic species were such as 50.1% for the marine sources ($Na^+$, $Mg^{2+}$, $Cl^-$), 30.9% for the anthropogenic sources ($NH_4{^+}$, $nss-SO_4{^{2-}}$, $NO_3{^-}$), and 4.7% for the soil source ($nss-Ca^{2+}$), and 3.1% for organic acids ($HCOO^-$, $CH_3COO^-$). From the seasonal comparison, the concentrations of $NO_3{^-}$, $nss-Ca^{2+}$, and $nss-SO_4{^{2-}}$ increased in winter and spring seasons, indicating a reasonable possibility of long range transport from Asia continent. Especially, the acidifying contributions by major inorganic acids ($nss-SO_4{^{2-}}$ and $NO_3{^-}$) and organic acids ($HCOO^-$ and $CH_3COO^-$) were 87.6% and 12.4%, respectively. In comparison by sectional inflow pathway of air mass during the rainy sampling days, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ were relatively high when the air mass was moved from the China continent into Jeju area.

PU/PMMA Hybrids의 물성에 대한 이온성기와 MMA함량의 영향 (The Effect of Ionic Group and MMA Contents on the Physical Properties of PU/PMMA Hybrids)

  • 정창남;조항규;노시태
    • 공업화학
    • /
    • 제8권4호
    • /
    • pp.575-581
    • /
    • 1997
  • 두 종류의 폴리올(PTMG, PBEAG), 이온성 쇄연장제(DMPA), $H_{12}-MDI$ 및 EDA를 이용하여 폴리우레탄 수분산체(PUD)를 합성하였다. PU/PMMA hybrid는 PUD를 MMA 단량체로 팽윤 시킨 후 라디칼중합으로 제조하였다. 이온기에 따른 PUD의 입자 크기 및 필름 물성을 검토하였으며, MMA 함량에 따른 hybrid의 기계적, 열전 성질을 검토하였다. PUD내 dimethylol propionic acid(DMPA)의 함량을 2, 4, 6, 8, 10wt%까지 증가시켰을 때 유화 입경이 감소하였으며, 또한 에테르형 폴리올보다 에스터형 폴리올을 사용한 PUD의 유화 입경이 작았다. 필름 물성에 있어 이온기의 함량이 증가함에 따라 상분리도가 증가하는 것을 열적, 기계적 분석을 통해서 확인할 수 있었다. PU/PMMA hybrids에서 MMA의 함량이 증가함에도 PUD의 팽윤에 의한 유화 입경의 증가는 크지 않았다. PU의 에스터형은 DMPA의 함량이 6wt%까지, 에테르형 폴리올을 썼을 경우 DMPA 함량이 4wt%까지 기계적 강도가 MMA 단량체의 함량이 증가함에 따라 높아졌고, DSC분석에서 $T_g$는 상승하고 완만해지는 것을 확인하여 hybrid가 분자 수준의 혼합이 이루어지고 있음을 알 수 있었다.

  • PDF

인자분석을 이용한 광주지역 미세먼지(PM10)의 특성 연구 (Characteristics of PM10 in Gwangju Using Factor Analysis)

  • 이세행;서광엽;윤상훈;양윤철;김선정;조영관;배석진
    • 한국환경과학회지
    • /
    • 제27권4호
    • /
    • pp.241-250
    • /
    • 2018
  • The objective of this study was to estimate air quality trends in the study area by surveying monthly and seasonal concentration trends. To do this, the mass concentration of $PM_{10}$ samples and the metals, ions, and total carbon in the $PM_{10}$ were analyzed. The mean concentration of $PM_{10}$ was $33.9{\mu}g/m^3$. The composition of $PM_{10}$ was 39.2% ionic species, 5.1% metallic species, and 26.6% carbonic species (EC and OC). Ionic species, especially sulfate, ammonium, and nitrate, were the most abundant in the $PM_{10}$ and had a high correlation coefficient with $PM_{10}$. Seasonal variation of $PM_{10}$ showed a similar pattern to those of ionic and metallic species. with high concentration during the winter and spring seasons. $PM_{10}$ showed high correlation with the ionic species $NO_3{^-}$ and $NH_4{^+}$. In addition, $NH_4{^+}$ was highly correlated with $SO{_4}^{2-}$ and $NO_3{^-}$. We obtained four factors through factor analysis and determined the pollution sources using the United States Environmental Protection Agency(U.S. EPA) pollution profile. The first factor accounted for 51.1% of $PM_{10}$ from complex sources, that is, soil, motor vehicles, and secondary particles: the second factor indicated marine sources; the third factor, industry-related sources; and the last factor, heating-related sources. However, the pollution profile used in this study may be somewhat different from the actual situation in Korea because it was from US EPA. Therefore, to more accurately estimate the pollutants present, it is necessary to create a pollution profile for Korea.