• Title/Summary/Keyword: Ion-chromatography

Search Result 1,271, Processing Time 0.027 seconds

Synthesis and characterization of polymer electrolyte membrane for fuel cell including sulfonated bis (4-fluorophenyl) phenylphosphine oxide (술폰화된 비스(4-플루오로페닐) 페닐포스핀옥사이드를 포함한 연료전지용 고분자 전해질막의 합성과 특성분석)

  • Yoo, Eun Sil;Nahm, Kee Suk;Yoo, Dong Jin
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.176-183
    • /
    • 2016
  • This study relates to a polymer electrolyte membrane for improved performance fuel cell, were researched with respect to properties required for driving a fuel cell. The bis(4-fluorophenyl)phenyl phosphine oxide was sulfonated using fuming sulfuric acid. Synthetic hydrophilic oligomer and the hydrophobic oligomer and the block copolymers were prepared via aromatic nucleophilic substitution polycondensation. A block copolymer structure and degree of sulfonation was analyzed by $^1H$-NMR and gel permeation chromatography(GPC) analysis. Thermal stability was confirmed by thermogravimetric analysis(TGA), block copolymer was stable at high temperature(>$200^{\circ}C$), The ion conductivity was measured in order to demonstrate the performance of fuel cell. Synthesis membrane was the increase of temperature was improved conductivity up to 58 mS/cm due to the influence of the developed ion clusters. The phase separation of the polymer was observed to make AFM analysis.

Glycomacropeptide Hydrolysed from Bovine K-Casein ; II. Chromatographic Changes of k-Casein Macropetide as Related to Trichloroacetic Acid Concentration (우유의 k-Casein에서 분해된 Glycomacropeptide에 관한 연구; II. Trichloroacetic Acid의 농도에 따른 k-Casein Macropeptide 분별 특성의 변화)

  • Moon Yong-Il;Lee Wonjae;Oh Sejong
    • Food Science of Animal Resources
    • /
    • v.25 no.4
    • /
    • pp.478-482
    • /
    • 2005
  • Bovine k-casein macropeptide was prepared by adding TCA (3, 6, and $12\%$) treatment after chymosin reaction. Each TCA soluble macropeptide was fractionated into five peak by ion exchange column chromatography. In proportiion to TCA concentrations, the ratio of peak area showed different the elution pattern. At the 6 and $12\%$ TCA concentration, area ratio of P-I which did not content carbohydrates was decreased to 19.9 and $17.0\%$ of total peak area respectively. The area of P-III was changed from $10.2\%\;to\;26.2\;and\;13.2\%$ when the TCA concentration was increased from 3 to 6 and $12\%$ Cholera toxin binding activity of k-casein macropeptide eluted at $0.17\~0.18M$ NaCl gradient was not inhibited by 6 and $12\%$ TCA treatments. The use of $6\%$ TCA as extraction buffer was feasible and led to an effective separation of the peak III.

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

The Analysis of Perchlorate in Nakdong River and Tap Water (낙동강 수계 및 수돗물에서의 Perchlorate($ClO_4^-$) 분석)

  • Kim, Hwa-Bin;Oh, Jeong-Eun;Lee, Sung-Yun;Cho, Jae-Weon;Snyder, Shane
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.776-781
    • /
    • 2006
  • Perchlorate ion($ClO_4^-$), which is present in the solid propellant for rocket, herbicide and some fertilizers. Perchlorate inhibits iodide uptake by the human thyroid gland. Impairment of thyroid function in expectant mothers may impact the fetus and result in effects including cerebral palsy, give rise to thyroid gland cancer. The US EPA(Environmental Protection Agency) adopted a reference dose(RfD) for perchlorate 0.0007 mg/kg-day, and this guidance lead to a Drinking Water Equivalent Level(DWEL) of 24.5 ${\mu}g/L$. The studies about perchlorate are actively performed in foreign countries, especially in USA but there is no study which surveyed the perchlorate contamination in Korea. Therefore, this study was done to investigate perchlorate contamination in Nak-dong river and tap water. The perchlorate was detected in Nakdong river and ranged from ND to 278.4 ${\mu}g/L$. The highest concentration was observed in Kumichon. The perchlorate concentration was decreased with the down stream of Nakdong river. The perchlorate concentration in tap water was varied with the cities and the concentration levels were $ND{\sim}34.1$ ppb. The highest perchlorate concentration was observed in DalsuGoo in Daegu and the similar concentration($9{\sim}11$ ${\mu}g/L$) was detected in most of the districts in Busan. The result of this study suggests that there is a perchlorate source near the Nakdong river and the urgent policy is needed to control perchlorate for the cities which are supplied from Nakdong river as for their tap water.

Liquid Chromatographic Separation of Salicylic Acid and Its Derivatives Using Amberlite XAD-Copolymers (Amberlite XAD-공중합체를 이용한 살리실산 및 크로마토그래피적 분리 그 유도체들의 액체)

  • Yong Soon Chung;Taik Hyuk Lee;Young Ja Moon;Dai Woon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.70-81
    • /
    • 1989
  • Reverse phase liquid chromatographic elution behaviors of salicylic acid and its derivatives were studied with classical and modern high-performance liquid chromatography(HPLC) using Amberlite XAD-4 and XAD-7 resin packed columns. Capacity factors(k') were determined in the comparatively high concentration(from 0. 010F to 0. 150F) of ferric nitrate-50% methanol solution to elucidate the elution behaviors with classical method. On the other hand, k's were measured in the various concentrations of methanol and ferric nitrate(from $2.5{\times}10^{-4}F\;to\;1.0{\times}10^{-3}F$) solution of pH 2. 25 and 293K with HPLC to explain the elution mechanism of them, and to find their optimum separation condition. As a result, it was found that log k's of salicylic acid and its derivatives were decreased with increasing the concentration of ferric ion, and the decreasing slopes of the compounds on the increasing ferric ion concentrations were related with each stability constant of ferric salicylates. Some isomers of derivatives of salicylic acid could be separated in the optimum condition.

  • PDF

A Study on Desalination Methods for Application of Outdoor Iron Artefacts (옥외 철제문화재 적용을 위한 탈염처리 방법 연구)

  • Lee, Hye-Youn;Cho, Nam-Chul;Kim, Woo-Hyun
    • Journal of Conservation Science
    • /
    • v.25 no.1
    • /
    • pp.49-60
    • /
    • 2009
  • Outdoor iron artefacts are easily corroded by salts, especially $Cl^-$ion, from environmental pollutants and acid rain because of their location, so that they need conservational treatments such as stabilization. However the conservation of outdoor iron artefacts are limited to be consolidated for the present and there are a few the studies for the desalinization. The general desalinization method is that objects are immersed in reagent such as alkaline corrosion inhibiting solutions targeting on buried iron artefacts, thus they are not available for outdoor iron artefacts. In this study, concerning those difficulties, the different desalting method is experimented that materials soaked in alkaline solutions attach to objects and they are packed by waterproof to avoid evaporation. This paper experiment burial iron artefacts at first in order to fine out an adaptable method for outdoor iron artefacts. The soaking materials are Korean traditional paper, gauze, cotton wipers, spill pads and the desalting regent is NaOH 0.1M. Additionally the exiting desalinization method which is to immerse objects in solution is performed to compare. The analyses are microscopes, SEM-EDS, X-ray diffraction, pH meter and Ion chromatography. The result is that spill pads show the best desalting effect out of other materials similar to immersing desalting method.

  • PDF

Determination of bromide in bottled mineral water and ground water in Korea (먹는 샘물 및 지하수 원수 중 bromide 분석연구)

  • Ahn, Hye-Sil;Seo, Kyoung-Ae;Park, Ju-Hyun;Lee, Jun-Bae;Kim, Tae-Seung;Han, Jin-Seok;Kwon, Oh-Sang
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.10-14
    • /
    • 2011
  • This study was performed to compare international analytical methods of bromide and applied to determine bromide in bottled mineral water and raw ground water in Korea. Bromide in water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatography-suppressed conductivity detector (IC-CD). Sample was purified with Ba- and H-on-guard cartridge and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromide were 0.2 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9993 in the ranges of the $0.5\sim80\;{\mu}g/L$. A correlation coefficient of bromide in ground water and sum of bromide and bromate in bottled mineral water is 0.808.

Identification of C3G(cyanidin-3-glucoside) from Mulberry Fruits and Quantification with Different Varieties (오디에서 C3G(cyanidin-3-glucoside)의 분리, 동정 및 계통별 함량분석)

  • 김현복;김선림
    • Journal of Sericultural and Entomological Science
    • /
    • v.45 no.2
    • /
    • pp.90-95
    • /
    • 2003
  • This study was carried out to identify of C3G (cyanidin-3-glucoside) from mulberry fruits and quantify with different varieties. C3G of mulberry fruits was extracted with 1% HCl-MeOH and purified with open column (5${\times}$90cm) which filled with Amberlite IRC-50 ion exchange resin. The $\lambda$max ranges of the purified C3G on UV/vis spectrum were 516nm and 280nm. Also, molecular weight of C3G from mulberry fruits by LC-Mass was determined as 449. From above results, we concluded that anthocyanin pigment of mulberry fruits was C3G only. The cyanidin-3-glucoside (C3G) was separated and quantified by High Performance Liquid Chromatography (HPLC) system using a Nova-Pack C$\_$18/ column. Mean content of the 35 tested accessions was 0.89%. Also fruity characteristics as well as C3G content to select the desirable mulberry varieties for the production of fruit were researched and analyzed. We selected three suitable varieties such as 'Susungppong', 'Kangsun', and 'Jeolgokchosaeng(Chungpuk)'.

Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column (Monolithic 칼럼을 이용한 뇨 중 유기용매 대사체의 신속한 HPLC 동시 분석)

  • Han, Sang Beom;Lee, Sang-Ju;Lee, Cheol-Woo;Yoon, Seo Hyun;Joung, Sun Kyung;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.433-440
    • /
    • 2006
  • A HPLC/UV method was developed and validated for the rapid and simultaneous determination of urinary metabolites of organic solvents, mandelic acid, hippuric acid, phenylglyoxylic acid, ortho-, meta- and para-methylhippuric acid, using a monolithic column. The mobile phase was composed of tetrabutylammonium bromide as ion-pairing reagent with a flow rate of 2.4 mL/min. The total run time was less than 2.5 min for all six analytes. Good linearities were obtained for all the metabolites with correlation coefficients above 0.9993. Intra-day precision, accuracy and inter-day precision was 0.01~7.32%, 83.9~116.3% and 0.01~7.16%, respectively. The method was validated and confirmed by quantification of the quality assurance samples of Industrial Safety and Health Research Institute, Korea Occupational Safety and Health Agency.