• Title/Summary/Keyword: Ion beam method

Search Result 411, Processing Time 0.029 seconds

Behavior of Hydroxide Ions at the Water-Ice Surface by Low Energy Sputtering Method

  • Kim, S.Y.;Park, E.H.;Kang, H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.338-338
    • /
    • 2011
  • The behavior of hydroxide ions on water-ice films was studied by using $Cs^+$ reactive ion scattering (RIS), low energy sputtering (LES) and temperature-programmed desorption (TPD). A $Cs^+$ beam of a low kinetic energy (<100 eV) from $Cs^+$ ion gun was scattered at the film surface, and then $Cs^+$ projectiles pick up the neutral molecules on the surface as $Cs^+$-molecule clusters form (RIS process). In LES process, the preexisting ions on the surface are desorbed by the $Cs^+$ beam impact. The water-ice films made of a thick (>50 BL) $H_2$O layer and a thin $D_2O$ overlayer were controlled in temperatures 90~140K. We prepared hydroxide ions by using Na atoms which proceeded hydrolysis reaction either on the ice film surface or at the interface of the $H_2O$ and $D_2O$ layers.[1] The migration of hydroxide ions from the $H_2O/D_2O$ interface to the top of the film was examined as afunction of time. From this experiment, we show that hydroxide ions tend to reside at the water-ice surface. We also investigated the H/D exchange reactions of $H_2O$ and $D_2O$ molecules mediated by hydroxide ions to reveal the mechanism of migration of hydroxide to the ice surface.

  • PDF

Fabrication of a Liquid Crystal Cell Using ITO-deposited Polarizers as Substrates (ITO 박막이 증착된 편광판을 기판으로 하는 액정 셀의 제작)

  • Jin, Hye-Jung;Kim, Ki-Han;Park, Kyoung-Ho;Son, Phil-Kook;Kim, Jae-Chang;Yoon, Tae-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • We propose a super-thin and light-weight liquid crystal cell, in which glass substrates are eliminated and polarizers are used as substrates. We fabricate a polarizer substrate by depositing a-SiOX as a buffer layer, indium-tin-oxide as a transparent conducting layer, and a-SiOX as an alignment layer on a polarizer sequentially at a low temperature. We use the ion-beam method to align liquid crystals on polarizer substrates.

A Study on Refresh Time Improvement of DRAM using the MEDICI Simulator (MEDICI 시뮬레이터를 이용한 DRAM의 Refresh 시간 개선에 관한 연구)

  • 이용희;이천희
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.4
    • /
    • pp.51-58
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. The novel junction process scheme in sub-micron DRAM cell with STI(Shallow Trench Isolation) has been investigated to improve the tail component in the retention time distribution which is of great importance in DRAM characteristics. In this' paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced ${\Delta}Rp$ (projected standard deviation) increase using buffered N-implantation with tilt and 4X(4 times)-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N-concentration which is Intentionally caused by ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation. And also, we suggest the least requirements for adoption of this new implantation scheme and the method to optimize the key parameters such as tilt angle, rotation number, Rp compensation and Nd/Na ratio. We used MEDICI Simulator to confirm the junction device characteristics. And measured the refresh time using the ADVAN Probe tester.

  • PDF

Study for Improvement of Laser Induced Damage of 1064 nm AR Coatings in Nanosecond Pulse

  • Jiao, Hongfei;Cheng, Xinbing;Lu, Jiangtao;Bao, Ganghua;Zhang, Jinlong;Ma, Bin;Liu, Huasong;Wang, Zhanshan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.1-4
    • /
    • 2013
  • For the conventionally polished fused silica substrate, an around 100 nm depth redeposition polishing layer was formed on the top of surface. Polishing compounds, densely embedded in the redeposition polishing layer were the dominant factor that limited the laser induced damage threshold (LIDT) of transmission elements in nanosecond laser systems. Chemical etching, super-precise polishing and ion beam etching were employed in different ways to eliminate these absorbers from the substrate. After that, Antireflection (AR) coatings were deposited on these substrates in the same batch and then tested by 1064 nm nano-pulse laser. It was found that among these techniques only the ion beam etching method, which can effectively remove the polishing compound and did not induce extra absorbers during the disposal process, can successfully improve the LIDT of AR coatings.

Investigation of Vortical Flow Field Visualization by Micro Water Droplet and Laser Beam Sheet (미세수적과 레이저 평면광에 의한 와류장의 가시화 연구)

  • 이기영;손명환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • A new off-surface visualization method of using the micro water droplet and laser beam sheet was presented. About a size of 5 to TEX>$10\mu\textrm{m}$ micro water droplet could be made from home-style ultrasonic humidifier, A 3 W Argon ion laser and cylindrical lens were used to generate a laser beam sheet, which interrogate specific cross section of the vortical flow field. Application of this new visualization method was conducted in KAFA small-sized low speed wind tunnel of having the test section of 0TEX>$0.9 m(W){\times}$0.9 m(H){\times}2.1 m(L)$$$. Visualization results show this method relatively easy and safe flow visualization method for wind tunnel testing. Moreover, this method is also make up for the disadvantage of smoke visualization, and can be applied to higher flow velocity range than that of smoke visualization.

Preparation and Characterization of Polypyrrole Electroactive Actuators (Polypyrrole를 이용한 전기활성 구동기의 제조 및 특성)

  • 박정태;최혁렬;김훈모;전재욱;남재도
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.826-832
    • /
    • 2001
  • In this study, PPy/gold/mylar type electroactive bi-layer actuator was prepared by the electrochemical polymerization of pyrrole onto the gold/mylar film and the actuation characteristics were studied using bending beam method. Conducting polymer-based actuators undergo volumetric changes due to the movement of dopant ions into the film during the electrical oxidation process. The bilayer films exhibited different actuation characteristics depending on dopant ion size. It was observed that the relatively small dopant ion (i.e. toluene sulfonate) moved into the PPy film at oxidized state, so volume expanded to result in bending motion. In case of the film having large dopant ion (i.e. dodecylbenzenesulfonate), volume expansion was observed at reduced state. This is due to the incorporation of $Na^+$ counterion with water molecules, while the large dopant ion was fixed in the film due to the limited mobility during tile redox process.

  • PDF

Fabrication of waveguide using UV Ar-ion laser direct writing (Laser Direct Writing 방법을 이용한 광도파로 제작)

  • Kang H. S.;Suh J.;Lee J. H.;Kim J. O.
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

The histometric analysis of osseointegration in hydroxyapatite surface dental implants by ion beam-assisted deposition

  • Kim, Min-Kyung;Choi, Jung-Yoo;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Sung-Tae;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.363-372
    • /
    • 2008
  • Purpose: This study compared the effects of coating implants with hydroxyapatite (HA) using an ion beam-assisted deposition (IBAD) method prepared with machined, anodized, sandblasted and large-grit acid etched (SLA) surfaces in minipigs, and verified the excellency of coating method with HA using IBAD. Material and Methods: 4 male Minipigs(Prestige World Genetics, Korea), 18 to 24 months old and weighing approximately 35 to 40 kg, were chosen. All premolars and first molars of the maxilla were carefully extracted on each side. The implants were placed on the right side after an 8 week healing period. The implant stability was assessed by resonance frequency analysis (RFA) at the time of placement. 40 implants were divided into 5 groups; machined, anodized, anodized plus IBAD, SLA, and SLA plus IBAD surface implants. 4 weeks after implantation on the right side, the same surface implants were placed on the left side. After 4 weeks of healing, the minipigs were sacrificed and the implants were analyzed by RFA, histology and histometric. Results: RFA showed a mean implant stability quotient (ISQ) of $75.625{\pm}5.021$, $76.125{\pm}3.739$ ISQ and $77.941{\pm}2.947$ at placement, after 4 weeks healing and after 8 weeks, respectively. Histological analysis of the implants demonstrated newly formed, compact, mature cortical bone with a nearby marrow spaces. HA coating was not separated from the HA coated implant surfaces using IBAD. In particular, the SLA implants coated with HA using IBAD showed better contact osteogenesis. Statistical and histometric analysis showed no significant differences in the bone to implant contact and bone density among 5 tested surfaces. Conclusion: We can conclude that rough surface implants coated with HA by IBAD are more biocompatible, and clinical, histological, and histometric analysis showed no differences when compared with the other established implant surfaces in normal bone.

Growth Model of Bi-Superconducting Thin Film Fabricated by Co-sputtering Method (동시 스퍼터법으로 제작한 Bi 초전도 박막의 성장 모델)

  • Chun, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.796-799
    • /
    • 2002
  • BSCCO thin films are fabricated via a co-deposition process at an ultra-low growth rate using ion beam sputtering. The sticking coefficient of Bi element exhibits a characteristic temperature dependence. This temperature dependence of the sticking coefficient was explained consistently on the basis of the evaporation and sublimation processes of Bi$_2$O$_3$.

  • PDF

Sterilization Effect of the Ion-exchanger Filter Using by Radiation Graft Polymerization (방사선 그라프트 중합법을 이용한 이온교환 필터의 살균효과)

  • Kim, Ye-Jin;Hong, Yong-Cheol;Kim, Min
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.378-381
    • /
    • 2014
  • We studied the pasteurization effect of the microorganism involved in the water, using ion-exchanging filter made of the Radiation Induced Grafted Polymerization. This ion-exchanging filter is made by the graft polymerization of GMA, after irradiation of electron beam to the non-woven filter. Then, we made the ion-exchanging filter (EtA, DEA, SS) applying ion-exchanging base to the GMA filter. As a result, the density of the ion-exchanging base is shown as 2.38 mol/kg in case of EtA, 1.79 mol/kg in case of DEA and 0.75 mol/kg in case of SS. Through this filter made by this method, we measured the pasteurization power of E. coli. We found very high elimination rate such as log 4.65 in case of SS-dial filter, which is higher as 3.00 times in comparison with EtA, and 1.10 times in comparison with DEA. This data show the result is very excellent comparing with 3,000 CFU/ml. of city water treatment basis.