• Title/Summary/Keyword: Ion Size

Search Result 1,132, Processing Time 0.027 seconds

A Study on Biosorption of Calcium Ion Using Aerobic Granular Sludge (호기성 그래뉼 슬러지를 이용한 칼슘이온의 생물흡착에 관한 연구)

  • Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.8
    • /
    • pp.677-687
    • /
    • 2019
  • This study evaluated the biosorption properties of calcium ion using Aerobic Granular Sludge (AGS). A sequencing batch reactor was used to induce the production of Extracellular Polymeric Substances (EPS) through salinity injection, and the calcium ion adsorption efficiency was analyzed by a batch test. The EPS contents showed significant changes (104-136 mg/g MLVSS) at different salinity concentrations. The calcium ion adsorption efficiency was highest for AGS collected at 5.0% salinity, and it was confirmed that the biosorption efficiency of AGS was increased owing to the increase in EPS content. The results of the Freundlich isotherms showed that the ion binding strength (1/n) was 0.3941-0.7242 and the adsorption capacity ($K_f$) was 2.4082-3.3312. The specific surface area and the pore size of the AGS were $586.1m^2/g$ and 0.7547 nm, respectively, which were not significantly different from each other. It was confirmed that the influence of biological properties, such as EPS content, was relatively large among the factors affecting calcium ion adsorption.

Characteristics of Ion Compositions of the Respirable Particles in Seoul (도시대기중 호흡성 먼지의 이온성분 거동 특성)

  • 신은상;강병욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.24-31
    • /
    • 1994
  • Aerosol size distribution were determined in Seoul by Anderson sampler from October 1989 to September 1991 for the major ionic species(SO$_{4}$$^{2-}$, NO$_{3}$$^{-}$, Cl$^{-}$, Na$^{+}$, Na$^{+}$, K$^{+}$, Ca$^{2+}$ and Mg$^{2+}$) and TSP( Total Suspended Particles ). The seasonal variations in concentrations and size distribution have been investigated. The size distributions of TSP and each of ionic species were bimodal throughout the year. The size distribution of these ions were divided as follows; (1) fine- mode dominant for SO$_{4}$$^{2-}$ and N%'. (2) coarse- mode dominant for NO$_{3}$$^{-}$, Cl$^{-}$, Ca$^{2+}$ and Mg$^{2+}$. (3) both- mode dominant for TSP.

  • PDF

Synthesis of Iron Oxide Using Ferrous and Ferric Sulfate (황산제일철과 황산제이철을 이용한 산화철 합성)

  • Eom, Tae-Hyoung;Tuan, Huynh Thanh;Kim, Sam-Joong;Suh, Dong-Soo
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.301-306
    • /
    • 2010
  • The chemical formula of magnetite ($Fe_3O_4$) is $FeO{\cdot}Fe_2O_3$, t magnetite being composed of divalent ferrous ion and trivalent ferric ion. In this study, the influence of the coexistence of ferrous and ferric ion on the formation of iron oxide was investigated. The effect of the co-precipitation parameters (equivalent ratio and reaction temperature) on the formation of iron oxide was investigated using ferric sulfate, ferrous sulfate and ammonia. The equivalent ratio was varied from 0.1 to 3.0 and the reaction temperature was varied from 25 to 75. The concentration of the three starting solutions was 0.01mole. Jarosite was formed when equivalent ratios were 0.1-0.25 and jarosite, goethite, magnetite were formed when equivalent ratios were 0.25-0.6. Single-phase magnetite was formed when the equivalent ratio was above 0.65. The crystallite size and median particle size of the magnetite decreased when the equivalent ratio was increased from 0.65 to 3.0. However, the crystallite size and median particle size of the magnetite increased when the reaction temperature was increased from $25^{\circ}C$ to $75^{\circ}C$. When ferric and ferrous sulfates were used together, the synthetic conditions to get single phase magnetite became simpler than when ferrous sulfate was used alone because of the co-existence of $Fe^{2+}$ and $Fe^{3+}$ in the solution.

Electrochemical Properties of Commercial NCA Cathode Materials for High Capacity of Lithium Ion Battery (상용 고용량 리튬이온이차전지용 NCA 양극활물질의 전기화학적 특성)

  • Jin, En Mei;Lee, Ga-Eul;Na, Byuong-Ki;Jeong, Sang Mun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.163-169
    • /
    • 2017
  • In order to investigate the electrochemical properties and the particle size effect of $LiNi_{1-x-y}Co_xAl_yO_2$ (x=0.15, y=0.045 or 0.05, NCA) for lithium ion batteries (LIBs), two commercial NCA cathode materials (NCA#1, NCA#2) were used as cathode materials for LIB. The average particle size of the NCA#1 which consisted of uniform spherical particles was found to be approximately $5m{\mu}$. NCA#2 consisted of particles with bimodal size distribution of approximately $5m{\mu}$ and $11m{\mu}$. From the results of charge-discharge performance test, a high initial discharge capacity of 197.0 mAh/g was obtained with NCA#2, which is a higher value than that with NCA#1. The cycle retentions of NCA#1 and NCA#2 up to 30 cycles were 92% and 94%, respectively.

Particle Beam Focusing Using Radiation Pressure (광압을 이용한 입자빔 집속)

  • Kim, Sang-Bok;Park, Hyung-Ho;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1505-1509
    • /
    • 2004
  • A novel technique for fine particle beam focusing under the atmospheric pressure is introduced using a radiation pressure assisted aerodynamic lens. To introduce the radiation pressure in the aerodynamic focusing system, a 25 mm plano-convex lens having 2.5 mm hole at its center is used as an orifice. The particle beam width is measured for various laser power, particle size, and flow velocity. In addition, the effect of the laser characteristics on the beam focusing is evaluated comparing an Ar-Ion continuous wave laser and a pulsed Nd-YAG laser. For the pure aerodynamic focusing system, the particle beam width was decreased as increasing particle size and Reynolds number. For the particle diameter of 0.5 ${\mu}m$, the particle beam was broken due to the secondary flow at Reynolds number of 694. Using the Ar-Ion CW laser, the particle beam width becomes smaller than that of the pure aerodynamic focusing system about 16 %, 11.4 % and 9.6 % for PSL particle size of 2.5 ${\mu}m$, 1.0 ${\mu}m$, and 0.5 ${\mu}m$ respectively at the Reynolds number of 320. Particle beam width was minimized around the laser power of 0.2 W. However, as increasing the laser power higher than 0.4 W, the particle beam width was increased a little and it approached almost a constant value which is still smaller than that of the pure aerodynamic focusing system. The radiation pressure effect on the particle beam width is intensified as Reynolds number decreases or particle size increases relatively. On the other hand, using 30 Hz pulsed Nd-YAG laser, the effect of the radiation pressure on the particle beam width was not distinct unlike Ar-Ion CW laser.

  • PDF

Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method (응축 증발법을 통한 서브마이크론 입자의 단극하전 특성)

  • Choi, Young-Joo;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

Theoretical Studies on MXO4 (M=Li, Na, K and X=F, Cl, Br, I) Salt Ion Pairs

  • Rashid, Mohammad Harun Or;Ghosh, Manik Kumer;Choi, Cheol-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2215-2218
    • /
    • 2010
  • The series of alkali metal perhalogenates, $MXO_4$ (M=Li, Na, K and X=F, Cl, Br, I) were theoretically studied with the help of MP2 methods. Bidentate as well as tridentate structures were found to be stable minima. The bidentate structures are becoming preferred as the size of halogen increases and as the size of metal decreases. Geometrically, the M-O and M-X distances of both bidentate and tridentate structures, increase with the size of metal. Generally, the M-$O_1$ distances of tridentate forms are longer than the corresponding distances of bidentate forms, while the M-X distances of tridentate forms show the opposite trend. Similarly, the X-O bonds increase with the size of halogens except $MXO_4$ pairs, where the X-O bonds are unusually long due to the enhanced oxygen-oxygen repulsions. In short, the relative energetics as well as the geometrical parameters are found to be strongly dependent on halogen and metal elements.

The Effect of Particle Size Distribution of the Nongraphitic Carbon on the Performance of Negative Carbon Electrode in Lithium Ion Secondary Battery (무정형 탄소의 입도분포에 따른 리튬이온이차전지의 탄소부극 특성)

  • Kim, Hyun-Joong;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.781-785
    • /
    • 1998
  • Material and electrochemical characteristics of petroleum coke of the nongraphitic carbon prepated with attrition milling for 6~48 hours and heat-treatment at $700^{\circ}C$ for 1 hour was investigated. The milling condition affects the particle size distribution, BET specific surface area and interlayer distance of petroleum cokes. Carbon electrode with petroleum cokes prepared at the milling time of 12~24 hours and having average particle size of $6{\sim}8{\mu}m$ showed best electrochemical characteristics form the investigation of cyclic voltammogram and charge-discharge characteristics.

  • PDF

Effect of pore structure on electrochemical performance of EDLC (EDLC의 전기화학적 성능에 대한 메조기공 구조의 효과)

  • Lee, Myung-Suk;Shin, Yun-Sung;Lee, Jong-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.310-317
    • /
    • 2010
  • The electrochemical properties of electric double layer capacitor(EDLC) was studied by controlling pore size distribution and specific surface area of the activated carbon fiber(ACF). The mesoporous ACF, which was prepared by the iron exchange method, showed the tendency of increasing average pore size and decreasing total surface area. The mesoporous ACF (surface area = 2225 $m^2$/g, pore size=1.93 nm) showed increased mesopore(pore size=1~3nm) volume from 0.055 cc/g to 0.408 cc/g compared to its raw ACF. The charging capacity of the EDLC which uses the prepared mesoporous ACF also increased from 0.39 F/$cm^2$ to 0.55 F/$cm^2$. From these results, it can be known that the electrochemical properties of EDLC are mainly dependent on the specific surface area, but above the surface area 2200 $m^2$/g, it is the mesopore volume that affects the performance of the capacitor considerably. Because the increased mesopore volume results in a decreased ion mobility resistance, the charge capacitance is enhanced.

A Study on the Fabrication of STS 316L Films by Ion Beam Deposition with Ion Source (이온빔 보조 증착법을 이용한 STS 316L 박막 합성에 관한 연구)

  • Lee, J.H.;Song, Y.S.;Lee, K.H.;Lee, K.H.;Lee, D.Y.;Yoon, J.K.
    • Korean Journal of Materials Research
    • /
    • v.13 no.9
    • /
    • pp.587-592
    • /
    • 2003
  • The thin films of 316L stainless steel were made on glass and S45C substrate by Ion beam assisted deposition with reactive atmosphere of argon and nitrogen. The films were deposited at the various conditions of ion beam power and the ratios of Ar/$N_2$gas. Properties of these films were analyzed by glancing x-ray diffraction method(GXRD), AES, potentiodynamic test, and salt spray test. The results of GXRD showed that austenite phase could be appeared by $N_2$ion beam treatment and the amount of austenite phase increased with the amount of nitrogen gas. The films without plasma ion source treatment had the weak diffraction peak of ferrite phase. But under the Ar plasma ion beam treatment, the strong diffraction peaks of ferrite phase were appeared and the grain size was increased from 12 to 16 nm. Potentiodynamic polarization test and salt spray test indicated that the corrosion properties of the STS 316L films with nitrogen ion source treatment were better than bulk STS 316L steel and STS 316L films with Ar ion source treatment.