• 제목/요약/키워드: Ion Selective Electrode

검색결과 184건 처리시간 0.023초

Tribenzylamine Ionophore를 이용한 pH-ISE의 제조 및 임상응용 (Preparation and Clinical Application of pH-ISE(Ion Selective Electrode) Based on Tribenzylamine Ionophore)

  • 조동회;박정오
    • 대한임상검사과학회지
    • /
    • 제38권1호
    • /
    • pp.59-64
    • /
    • 2006
  • The pH-ISE(ion selective electrode) based on tribenzylamine as a hydrogen ion carrier was prepared and its electrochemical characterization was studied. It responded linearly to hydrogen ions in the range of pH 3.1 - pH 11.0 and the Nernstian slope showed 55.0 mV/pH (at $20{\pm}0.2^{\circ}C$), it also showed a fast response time of 8 sec. When it was directly applied to human blood(pH 6.0-8.5), we could get the same satisfying results. A good reproducibility and stability were shown with the precision of 2 mV (${\pm}0.1$). The pH-ISE based on tribenzylamine exhibited biocompatibility in clinical applications.

  • PDF

(Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) 착물의 질산이온 선택성 막전극 (Nitrate Ion-Selective Membrane Electrode Based on Complex of (Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) Nitrate)

  • 신두순;정기원
    • 대한화학회지
    • /
    • 제36권3호
    • /
    • pp.383-392
    • /
    • 1992
  • (Bakelite-A)-(2,2'-Bipyridine)-Ni(Ⅱ) Nitrate 착물 막전극이 질산 이온 선택성 막전극이 됨을 확인하였다. 이 막전극은 수소 이온이나 2가 및 3가 음이온에는 감응하지 아니하였고, 특히 이 막전극의 수명, 감응 농도 범위, 감응 시간 및 이온 선택성 등 전기 화학적 성질과 착물 리간드의 유성도 크기 사이의 관계를 비료 고찰하였고, 또한 막의 최적 조건의 착물조성 구조로부터 막의 이온교환 메카니즘을 고찰하였다.

  • PDF

질산이온 선택성 피복선 전극의 제작 및 환경분석에의 응용 (Preparation of Coated-Wire Nitrate Ion Selective Electrode and its Application for Environmental Analysis)

  • 李龍根;金昌圭;朴廷泰;金京燮;黃圭子
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.99-107
    • /
    • 1985
  • A coated wire ion selective electrode for nitrate (nitrate-CWE_ was constructed using epoxy resin, ion exchanger and plasticizer as a polymer membrane. It's stility, the composition of a polymer membrane, the response characteristics, the selectivity were examined and applied to the environmental analysis. The nitrate-CWE was prepared using a copper wire, wihch was coated with epoxy resin being incorporated with the nitrate ion exchanger and plasticizer. The best composition of the polymer membrane for the nitrate-CWE was obtained by mixing epoxy resin, ion exchanger and plasticizer in the ratio of 2:1:0.4. The potential (56.3$\pm$0.5 mV) of stick form nitrate-CWE in this composition was close to that (59.2 mV) of Nernstian response. The detection limit for nitrate ion were found to the about $6 \times 10^{-5}M$ and the useful pH was 2.5 $\sim$ 10.3. Furthermore, the selectivity of iodide and perchrorate for the nitrage-CWE was also much improved compared with that for a liquid membrane nitrate electrode. The nitrate-CWE was used to determind $NO_x$ in stack gas. The results were in good agreement with those obtained either by electrode method or by the improved NEDA method within a relative error of 4.0%.

  • PDF

이온교환수지 분말이 코팅된 탄소전극을 이용한 음이온 혼합용액에서 Nitrate 이온의 선택적 제거율 향상 (Enhancement of Selective Removal of Nitrate Ions from a Mixture of Anions Using a Carbon Electrode Coated with Ion-exchange Resin Powder)

  • 여진희;최재환
    • 공업화학
    • /
    • 제24권1호
    • /
    • pp.49-54
    • /
    • 2013
  • 혼합용액에서 nitrate 이온을 선택적으로 제거하기 위해 복합탄소전극을 제조하였다. 질산이온 선택성 수지(BHP55, Bonlite Co.) 분말을 탄소전극 표면에 코팅하여 전극을 제조하였다. 제조한 전극으로 BHP55 셀을 제작하여 chloride, nitrate, sulfate 이온이 혼합된 용액에 대해 축전식 탈염 실험을 수행하였다. 그리고 BHP55 셀에서의 질산 이온 제거량을 이온교환막을 결합한 MCDI 셀의 결과와 비교하였다. BHP55 셀에서 이온의 총 흡착량은 MCDI 셀에서 보다 31% 증가한 $38.3meq/m^2$를 나타냈다. 또한 BHP55 셀에서 질산 이온의 흡착량은 $15.9meq/m^2$ (전체 흡착량의 42%)이었고, 이는 MCDI 셀에서 보다 2.1배 큰 것으로 나타났다. 실험결과 제조한 복합탄소전극은 음이온 혼합용액에서 질산 이온을 선택적으로 제거하는데 매우 효과적임을 알 수 있었다.

폐수처리 공정중 유해음이온을 측정하기 위한 PVC 막 전극 (The PVC Membrane Electrode for Measuring Hazardous Anion in Waste Water Process)

  • 우인성;안형환
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.47-59
    • /
    • 1995
  • The perchlorate, thiocyanate, and nitrate ion-selective PVC membrance electrode for measuring hazardous anion in waste water were developed by incorporating the quaternary ammonium salts as active material. Ion-selective characteristics in waste water were studied by the useful pH range, the selective coefficients to various interfering anions, and the stability of electrode potential. DBP was best as a plasticizer. The effect of the membrane thickness on the electrode characteristics was improved with decreasing the membrane thickness, but below the optimum membrane thickness the electrode exhibited an inverse trend. The electrode potential of perchlorate, thiocyanate, and nitrate electrode with TDDA, as active material, was stable within the pH range 4-11, 3-12, and 4-10 repectively. And the long-term potential stability of these electrodes were 3.0, 3.5, and 3.5 months respectively. The order of the selectivity coefficients was as shown below ; $ClO_4{^-}$ > $SCN^-$ > $I^-$ > $NO_3{^-}$ > $Br^-$ > $CN^-$ > $F^-$ > $Cl^-$ > $Ac^-$ > $H_2PO_4{^-}$, $SO_4{^-}$.

  • PDF

Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier

  • Aghaie, M.;Giahi, M.;Zawari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2980-2984
    • /
    • 2010
  • A new poly (vinyl chloride) (PVC) membrane electrode that is highly selective to $Mn^{+2}$ ions was prepared using N,N'-bis(2'-pyridinecarboxamide)-1,2-ethane ($bpenH_2$) as a suitable neutral carrier. This concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-1}\;M$) with Nernstian slope of $29.3{\pm}0.5\;mV$ per decade. The detection limit and the response time of electrode were $8.0{\times}10^{-6}\;M$ and (${\leq}15\;s$) respectively. The membrane can be used for more than two months without observing any divergence. The electrodes exhibited excellent selectivity for $Mn^{+2}$ ion over other mono-, di- and trivalent cations. Selectivity coefficients were determined by the matched potential method (MPM). The electrode can be used in the pH range from 4.0 - 9.0. The isothermal coefficient of this electrode amounted to 0.00023 V/$^{\circ}C$. The stability constant (log $K_s$) of the $Mn^{+2}$ - $bpenH_2$ complex was determined at $25^{\circ}C$ by potentiometric titration in mixed aqueous solution. The proposed electrode was applied to the determination of $Mn^{+2}$ ions in real samples.

수경재배 시 다량 이온 농도 측정을 위한 이온 선택성 전극의 응용 (Application of Ion-Selective Electrodes to Measure Ionic Concentrations of Macronutrients in Hydroponics)

  • 김민수;박두산;조성인
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.37-43
    • /
    • 2007
  • This study was carried out to investigate the applicability of PVC membrane-based ion-selective electrodes for macronutrients (K, Ca, and N) by measuring of potassium, calcium, nitrate ions in hydroponic nutrient solution. The capabilities of two ion-selective membranes with varying chemical compositions for each ion were evaluated in terms of sensitivity, selectivity, and lifetime to choose sensing elements suitable for measuring typical ranges of nutrient concentrations in hydroponic solutions. The selected calcium and nitrate ion-selective membranes showed effectively sensitive responses to calcium and nitrate ions with lifetimes of 25 and 15 days, respectively. The addition of a cation additive to the potassium membrane cocktail allowed its sensitivity to be increased whereas its lifetime was reduced from 30 days to 10 days.

이온 선택성 전극을 이용한 의약품 정량: Calix[4]arene과 Dibenzo-18-crown-6-ether에 의한 verapamil-선택성 polymeric membrane electrode (Ion-Selective Electrodes in Drugs Analysis: Verapamil-Selective Polymeric Membrane Electrodes Based on Calix[4]arene and Dibenzo-18-crown-6-ether Ionophores)

  • 이은엽;김성진;김영학;김재현;허문회;안문규
    • 약학회지
    • /
    • 제39권1호
    • /
    • pp.61-67
    • /
    • 1995
  • PVC membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6, cyclic oligomers of teit-butylphenol-formaidehyde condensates, calix[4]arenes as the active sensors for verapamil have been prepared and tested in a variety of plasticizers. At pH 5.0, the electrode exhibits a Nernstian response in the range of 10$^{-2}$~5$\times$10$^{-5}$ M verapamil with a slope of 49.1$\pm$0.5mV per concentration decade. The electrode constructed in this work can be used continuously for at least 1 month before any damage to the membrane occurs. And the analyses of the local anesthetic amine, which are good to select a specific compound in a mixed solution, were also accomplished by using of another neutral carrier, a DB18C6, for comparing with calix[4]arene.

  • PDF

Determination of Nitrate in Chromium Plating Solution with Nitrate-Selective Electrodes

  • 강유라;이원;허황;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권3호
    • /
    • pp.221-226
    • /
    • 1995
  • A method for determining nitrate in post treatment chromium plating solutions with PVC-based nitrate-selective electrodes is described. PVC-based nitrate-selective membranes which contain TDMANO3 ion-exchanger in PVC/NPOE, PVC/DOA or PVC/DBP matrices, and a commercially available Corning electrode (No. 476134) have been compared in respect of their detection limits, response slopes, selectivities at various pHs, and dynamic response to the hydrochromate ion in basic condition. The PVC/DBP/TDMANO3 membrane electrode was chosen as the ISE detector for the determination of nitrate in the presence of hydrochromate interference. The amount of nitrate in real post treatment chromium plating solution could be determined successfully with this electrode in both static and flow-injection measurements when the sample was properly diluted with an alkaline buffer.

Highly Selective Triiodide Polymeric Membrane Electrode Based on Tetra(p-chlorophenyl)porphyrinato Manganese (Ⅲ) Acetate

  • Farhadi, Khalil;Shaikhlouei, Hossain;Maleki, Ramin;Sharghi, Hashem;Shamsipur, Mojtaba
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1635-1639
    • /
    • 2002
  • A new solvent polymeric membrane sensor based on tetra(p-chlorophenyl)porphyrinato manganese (III) acetate is described which demonstrates excellent selectivity toward the triiodide ion. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ M and 7.0 ${\times}$$10^{-6}$M with a Nernstian slope of $-59.6{\pm}1$ mV per decade and a detection limit of 5.0 ${\times}$$10^{-6}$M. The proposed sensor revealed good selectivities for triiodide over a wide variety of other anions and could be used in a pH range 2-9. The electrode can be used for at least two months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of the triiodide and As(III) ions.