• Title/Summary/Keyword: Inverter type

Search Result 849, Processing Time 0.026 seconds

A Novel Cost-Effective Two-Level Inverter with Combined Use of Thyristors and IGBTs

  • Chen, Dezhi;Zhao, Wenliang;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.152-159
    • /
    • 2018
  • In this paper, a novel topology of two-level voltage-type inverter is proposed. The proposed inverter has three bridge arms while each bridge is made up of two thyristors, one IGBT and four diodes. Thyristors complete the phase positioning of the inverter, IGBT completes the modulation of different modulation modes such as SPWM, SVPWM, and SHPWM, and the diodes complete the commutation of the bridge arms. Compared to the traditional voltage-type inverter with six IGBTs, the proposed voltage-type inverter using three IGBTs can achieve the same function with highly reduced cost. The principle of the proposed two-level inverter is explained in detail. The simulation and experiment results demonstrate the performance and effectiveness of the proposed inverter-type inverter.

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

A Study of 200kVA IGBT SIV development and production for electric coache (전기철도용 200kVA IGBT SIV 개발 및 제작에 관한 연구)

  • 이상석;신동희;김재문;김연충;원충연
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.309-313
    • /
    • 1997
  • The SIV(Static InVerter) of the electric coach mainly consists of GTO type inverter. But, it is the drawback that GTO type inverter must have the complicated driving circuits. Recently, appearing the IGBT of high speed switching frequency, simple driving circuits, relative large capacity, GTO type inverter is changed IGBT type inverter. In this paper, IGBT type SIV substituting for the existing GTO type SIV is designed and producted. The experimental results are presented to verify the performance of the designed IGBT type SIV.

  • PDF

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

Maximum Efficiency Operation of Three-Level T-type Inverter for Low-Voltage and Low-Power Home Appliances

  • Shin, Seung-Min;Ahn, Jung-Hoon;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.586-594
    • /
    • 2015
  • This paper proposes a maximum efficiency operation strategy for three-level T-type inverter in entire operation areas. The three-level T-type inverter has higher and lower efficiency areas compared with two-level inverter. The proposed strategy aims to operate in the maximum efficiency point for the low-voltage and low-power home appliances. The three-level T-type inverter is analyzed in detail, and the two operation mode selection strategy is developed. The proposed algorithm is verified by theoretical analysis and experimental results.

Design and Control of a Bidirectional Power Conversion System with 3-level T-type Inverter for Energy Storage Systems

  • Sung, Won-Yong;Ahn, Hyo Min;Oh, Chang-Yeol;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.326-332
    • /
    • 2018
  • In this paper, the design process and the control method of the power conversion system (PCS) that consists of a bidirectional DC-DC converter and a 3-level T-type inverter for an energy storage system is presented. Especially the design method of the output LCL filter for a 3-lvel T-type inverter without complex mathematical process are proposed. The validity of the control method and design process in this paper are verified through simulation and experimental analysis.

The effect of Harmonic Distortion Reduction on Three Phase Three level Inverter Using Neutral Point Control (3상 3레벨 인버터의 중성점 제어를 이용한 고조파 왜율 저감 효과)

  • Kim, Jeong Gyu;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.90-94
    • /
    • 2018
  • In this paper, we applied a three-level T-type inverter with the one more voltage level than two-level inverter. However, the three-level T-type inverter has a systematic problem with voltage unbalances. So neutral point control is essential. Therefore, the voltage unbalance problem of the three - phase inverter was confirmed to be controlled within 5V using the neutral point control algorithm in charge and discharge mode. In addition, total harmonic distortion was reduced in three phases (u phase, v phase, w phase) when neutral point control was performed in charging mode and also in three phases (u phase, v phase, w phase) in discharge mode. In this paper suggests a neutral point control algorithm to solve the voltage unbalance of a three-level T-type inverter, and shows the improvement of the performance of the proposed algorithm through experiment.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF

Study on T-Type Multi Level Inverter for UIPV System (계통연계형 태양광발전 시스템을 위한 T-타입 타상 인버터에 관한 연구)

  • Bayasgalan, Bayasgalan;Ryu, Ji-Su;Lee, Sang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.313-314
    • /
    • 2012
  • In this paper presents study of T-Type multi level inverter for utility interactive photo voltaic inverter. In order to increase efficiency and performance of utility interactive photo voltaic (UIPV) system, we propose multi level PCS topology, such as T-type inverter. The control algorithm for utility interactive inverter is implemented by simulation and experimentation, which includes dc-bus and midpoint voltage controller, ac-grid current controller and PLL algorithm.

  • PDF