• Title/Summary/Keyword: Inverter transformer

검색결과 419건 처리시간 0.025초

3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션 (3kW multi-string photovoltaic inverter design and simulation)

  • 이종인;유병규;유권종;김흥근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

LCD 구동 Backlight Inverter용 변압기의 설계 방법과 특성 분석 (The Characteristic Analysis and Design of Transformer for LCD Backlight Inverter)

  • 김윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권7호
    • /
    • pp.353-361
    • /
    • 2006
  • This paper presents the design scheme of transformer for backlight inverter and discuss the characteristics related to its design, including driving inverter. A few studies have so far been made at design and characteristics analysis of transformer. Therefore, this paper manages the presentation of the advisable design methodology of transformer for backlight inverter supplying CCFL. To verify the proposed method, this paper accomplishes the analysis by FEM coupled with circuit and finally shows that the proposed design method is very useful.

Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

공통암을 이용한 3상 변압기 절연 멀티레벨 인버터 (3-Phase Transformer Isolated Multi-level Inverter Using Common Arm)

  • 송성근;박성준;김동옥;임영철;김광헌
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.149-156
    • /
    • 2007
  • 3상 변압기를 이용한 멀티레벨 인버터는 단상 변압기를 이용한 경우에 비해 변압기 수를 줄일 수 있으며, 변압기 이용률을 증대시켜 변압기 크기를 줄일 수 있다는 장점이 있으나 많은 수의 스위치 소자가 필요하다는 단점이 있다. 이에 본 논문에서는 공통암을 이용하여 스위치 수를 줄인 3상 변압기 절연 멀티레벨 인버터를 제안한다. 제안한 인버터는 스위칭 주파수를 기본주파수와 동일하게 제어하면서 등면적 법에 의해 도통각을 제어 하여 출력전압의 THD 감소 및 스위치 손실을 줄였다. 또한 Matlab을 이용한 시뮬레이션 및 실험을 통하여 제안된 방식의 타당성을 검증 하였다.

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

단권변압기 탭 절환 방식에 의한 이중 접속 변형전류형 인버터의 고주파 저감 (Reduction Harmonics in Double Connected Modified Current Source Inverter by Switching Taps on Auto Transformer)

  • 이공희;한우용
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권2호
    • /
    • pp.69-76
    • /
    • 1994
  • An effective method for reducing the harmonics in double connected modified current source inverter[MCSI] by switching taps on auto transformer is presented in this paper. The proposed system operates as like a 24 step MCSI by adding only tap changing auxiliary circuit which consists of several taps and static switching elements to the 12 step multiple inverter, which is double connected three-phase six-step MCSI with an auto transformer. The basic theories of the proposed inverter systems for analyzing the output waveforms are described. And to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and the tap changing control angle of auto transformer are decided by digital simulation and its validity is verified by experiment. Although the construction of the proposed inverter is very simple, it is clarified that the output waveform of the inverter is almost the same as that of the conventional 24 step multiple inverter under the optimum condition.

  • PDF

Grid-Connected Three-Phase Inverter System with Sub Inverter using Combination Type UPFC Structure

  • Park, Seong-Mi;Vi, Le Thi Tuan;Jeong, Da-Woom;Park, Sung-Jun;Park, Jang-Sik
    • 한국산업융합학회 논문집
    • /
    • 제23권4_1호
    • /
    • pp.559-567
    • /
    • 2020
  • As the renewable energy market grows, grid-connected inverters have been improving and expanding in several fields in recent years because energy conversion devices are the main components of solar systems. In this paper, a high-precision new grid-connected three-phase inverter system is proposed. The proposed system consists of a main inverter, a sub inverter and a transformer. The main inverter operates at a low switching frequency and high power and transmits power to the grid. A sub-inverter connected in series with the transmission line through a matching transformer operates at lower power than the main inverter to provide input values to the transformer. The transformer acts as a power supply according to the voltage compensation value. This study is based on the principle of operation of the UPFC(Unified Power Flow Controller) structure used to regulate power flow in AC transmission lines. The grid-connected inverter system proposed in this paper is implemented with high precision and high resolution. The proposed system was verified through its ability to enhance and ensure the safety of the proposed system through simulation and experiment.

12 펄스 인버터에서 결합변압기를 이용한 고조파 제거기법 (Harmonic Elimination Method of Using Coupling Transformer in Twelve Pulse Inverter)

  • 정창용;이영운;최규형;오태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.613-615
    • /
    • 1996
  • Harmonic elimination method of using coupling transformer in twelve pulse inverter is presented for high power application. This method is using coupling transformer and PWM(pulse width modulation) switching and voltage source inverter. The object of proposed harmonic elimination method is obtained inverter output of low THD(Total Harmonic Distortion). The simulation results confirm the proposed harmonic elimination method.

  • PDF

압전 변압기 이용 Full-Bridge형 인버터 설계 (Design of the full-Bridge type Piezoelectric Inverter)

  • 임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2000
  • The backlight inverter used in a laptop computer is investigated in this paper. It has been difficult for the electromagnetic transformer in the inverter to have a high efficiency and compact profile. In this study the piezoelectric transformer(PT) is used to reduce the loss and volume compared to the standard electromagnetic transformer. Comparison with the experimental inverter with the PT has been shown to validated the simulation program using the equivalent circuit model of the PT. A simple dimming control circuit was experimentally demonstrated and shown to have broad control.

  • PDF

LCD TV용 고균일도 백라이트 구동을 위한 Differential Driving 인버터 (Differential Driving of Inverter for High Uniformity LCD TV Backlight)

  • 전영태;임성규
    • 마이크로전자및패키징학회지
    • /
    • 제11권2호
    • /
    • pp.37-41
    • /
    • 2004
  • LCD TV의 백라이트로서는 cold cathode flourescent lamp (CCFL)를 병렬로 구성한 직하방식의 백라이트 많이 사용되고 있다. 현재 각 각의 CCFL에 transformer 한개 씩을 사용하여 일정한 전류를 공급함으로서 백라이트의 균일도를 얻고 있으나 본 논문에서는 differential driving inverter를 이용하여 transfomer에 8개의 램프를 연결하여 구동함으로써 transformer의 개수를 현저히 줄일 수 있었다. Differential driving 방법을 이용하여 transformer 2개를 사용한 인버터를 제작하였으며 이를 이용하여 길이 450mm, 관경 4mm의 CCFL 16개를 사용한 26"용 LCD TV 백라이트를 구동할 수 있었다. 개발된 differential driving 인버터를 이용하여 백라이트를 구동한 결과 $88\%$ 이상의 휘도 균일도를 갖는 백라이트를 구현할 수 있었다.

  • PDF