• Title/Summary/Keyword: Inverter surge

Search Result 68, Processing Time 0.023 seconds

Ground Impedance and Frequency Response Characteristics of Large-scale Ground Rods (대형 봉상 접지전극의 접지임피던스와 주파수 응답특성)

  • Lee, Bok-Hee;Eom, Ju-Hong;Kim, Tai-Doo;Chung, Dong-Chul;Kil, Hyeong-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1791-1793
    • /
    • 2003
  • In order to analyze the dynamic characteristics of ground impedance in large grounding system for lightning and surge protections, a novel method for measuring the ground impedance as a function of frequency was proposed. The experiments were carried out in the grounding system composed of ground rods and mesh grids. The test current was injected by the variable frequency inverter whose frequency is linearly controlled in the range of $5{\sim}500$kHz. The ground impedance and frequency response of the grounding system were mainly caused by the inductive current flowing through grounding conductors over the frequency of 2002. In the combined grounding system of rods and mesh grids, inductive component of ground impedance was significantly decreased. It was fumed out that the grounding system is effective for the surge protection.

  • PDF

Properties of Electrical Performance by Inverter Surge on Stator Coil of Traction Motor (인버터 서지에 의한 견인전동기 고정자 권선의 전기적 특성 변화)

  • Park, Hyun-June;Jang, Dong-Uk;Choi, Nam-Ho;Choi, Jong-Sun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1285-1287
    • /
    • 2003
  • The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking. the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss($tan{\delta}$), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.

  • PDF

A Study of Korean Efficiency of PV PCS (태양광 인버터의 한국형 전력변환 효율에 관한 연구)

  • Kim, Jeong-Hwan;Yu, Byung-Gyu;So, Jung-Hun;Lee, Ki-OK;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.356-360
    • /
    • 2009
  • Recent global environmental pollution and contamination and depletion of limited fossil energy prices surge as an energy source to replace it depending on wind, fuel cells and solar power and other renewable and pollution free renewable energy is of interest in increase. The photovoltaic systems are pollution-free, unlimited energy source, and easy to install because it is rated as the most valuable renewable energy sector and the prevalence is spreading throughout the world. Photovoltaic systems at one end of the stable development of the role that solar power inverter applications can be the most important. No matter how much power the solar arrays, even if the inverter output in the normally if he's no use. These photovoltaic inverters to evaluate the performance of the inverter efficiency measures that can be called directly. This way of measuring the efficiency of solar inverters in Europe efficiency and CEC efficiency is currently being used. In this paper, until now about how to measure the efficiency of solar power inverter technology and the new Korean Meteorological Solar Insolation data analysis to derive weights based on this inverter efficiency for Korea is to offer.

  • PDF

A Study on the Evaluation of Reliability and Expected Life for the Insulation System of Traction Motors in Urban Transit E.M.U (철도차량용 견인전동기의 수명예측 및 절연신뢰성 평가 방법에 관한 연구)

  • Wang, Jong-Bae;Kim, Sang-Keol;Lee, Heon-Don;Oh, Hyun-Seok;Kim, Ki-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.449-451
    • /
    • 1999
  • When the traction motor for urban transit E.M.U is driven with VVVF controlled inverter, the insulation degradation factors on the 200 Class insulation system of VPI process are analyzed with considering dielectric, mechanical properties, thermal stability, chemical resistivity and compatibility. A new test method of complex accelerating degradation is proposed to evaluate the insulation reliability and the long-term life including harmonic loss and transient surge stress due to PWM inverter drive.

  • PDF

Development of Ground Impedance Measuring Instrument for Lightning Protection System (뇌보호 설비를 위한 접지임피던스 측정기 개발)

  • Lee, Tae-Hyung;Cha, Sung-Chul;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.194-195
    • /
    • 2006
  • This study evaluated the impedance characteristics of earth termination system and developed a variable frequency-typed inverter (measuring tool) for the utilization in ground design for lightning protection. The variable-frequency-typed inverter were composed of rectification part, voltage adjuster, IGBT controller and measuring part. Meanwhile, the square wave signal of variable frequency converted its frequency up to lightning surge band by using an IGBT after rectifying an alternating current (AC). It conducted performance evaluation of ground impedance of actual earth termination system by using the developed measuring tool for ground impedance and confirmed that such impedance-oriented performance evaluation was effective in the design of lightning protection.

  • PDF

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

Charge Pump Half-Bridge Inverter for LCD Backlight Drive Applications (LCD Backlight 응용을 위한 Charge Pump Half-Bridge Inverter 회로)

  • Park, Kyu-Min;Roh, Chung-Wook;Han, Sang-Kyoo;Hong, Sung-Soo;SaKong, Sug-Chin;Kwon, Gi-Hyun;Lee, Hyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.265-267
    • /
    • 2007
  • 본 논문은 LCD Backlight 구동을 위한 새로운 방식의 회로를 제안한다. 제안된 회로는 Charge Pump 캐패시터를 이용한 Half-Bridge 타입의 인버터로 Full Bridge 회로와 동등한 성능을 갖는다. 제안 회로는 넓은 입력 범위와 넓은 부하 범위에서 영전압 스위칭(ZVS) 확보가 가능해서 인버터의 고효율 동작이 확보되고, MOSFET의 surge 및 noise를 저감시킨다. 제안된 회로의 동작 원리를 설명하고, 시뮬레이션 및 40" LCD 패널에 실제 적용 실험하여, 회로의 동작을 입증하였다.

  • PDF

The Power Supply for High Frequency Induction Heating by using the Current Resonance (전류공진을 이용한 고주파 유도가열용 전원장치)

  • Ra, B.H.;Lee, E.Y.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.263-266
    • /
    • 2002
  • In this paper, It is indicating that an issues of the conventional boost converter for high frequency induction heating. To improve those issues, it is proposed, simulated and analyzed that the current resonant circuit, simulated. As the result, we knew that the proposed circuit has a good point to improve the waveform of input current and to make high efficiency. On the other side, in the inverter for the high current power supply, it is proposed that the high frequency inverter of the half bridge topology, be done the circuit analysis to extract the optimal circuit parameter. It is making sure of the soft switching operating by the inductor to reverse parallel connected on the inverter main switch, decreasing the surge voltage when the switch is turn-off by compulsion, and repressing the switch current and bringing the high current amplitude operation by the multi resonance.

  • PDF

Analysis of Motor Winding impact by inverter Switching Voltage Waveforms (인버터 스위칭전압 파형에 의한 전동기 권선 영향 해석)

  • 김종겸
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.94-101
    • /
    • 1999
  • In this paper the problems associated with the switching surge of PWM inverter devices were analysed. As the application of ASD for efficient speed control of AC rmtors is increased, so is the rrntor and ASD-related failure increased. In the industrial rmtor awlications, the introduction of PWM drives can sometmes cause insulation breakdown between the phase windings due to high transient voltage peak. The motor cable length combined with the high switching frequency becomes more sensitive issue for proper drive operation. Effects of the cable length and high switching frequency influence both on rmtor and inverter. When the insulation level of rmtor winding is low, the failure probability caused by high peak voltage and fast voltage rise times(dv/dt) is high. Voltage refloctions are simulated far rmtor capacities, ASD and rise times and are presented graphically. The filtering techniques are discussed to reduce the rmtor terminal overvoltage and dv/dt in inverter fed AC rrntor drive systems. We confirmed that the lower motar capacity and rmtar insulation level, the shorter switching time and cable length and the higrer the probability of insulation breakdown .kdown .

  • PDF

Optimal System Design and Minimization of Conducted EMI Noise in Elevator Inverter System by Customized IPM (주문형 IPM을 이용한 엘리베이터용 인버터의 최적화 설계 및 전도 EMI 노이즈 저감)

  • 조수억;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2003
  • This paper deals with the optimal design of a elevator inverter system based on the customized IPM. The proposed method reduces dv/dt and di/dt, which resulted in the minimized conducted EMI noise without an additional circuitry. It only optimizes the value of gate resistor in the IGBT embedded in the IPM. In order to optimize the customized IPM to a elevator system, we simulated and measured the spike voltage and the motor surge voltage including the temperature variation due to the switching losses at the IPM case and heat-sink. As a result, thanks to the optimized value of the gate resister in the IPM, the conducted EMI noise is reduced approx. 5∼10 [dB$\mu$V] in a particular frequency domain.