• Title/Summary/Keyword: Inverter control

Search Result 2,699, Processing Time 0.028 seconds

The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load (고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구)

  • 임영도;김두영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.192-199
    • /
    • 2000
  • This paper describes a Phase-Shift Pulse Modulation(PSPM) and Frequency Trad이ng Pulse Modulation(FTPM) s series resonant high-frequency inverter using IGBT for the power control of high-frequency induction heating u using Neuro-Fuzzy, which is practically applied for 20kHz~500kHz induction-heating and melting power supply in i indust껴aJ fields. The adaptive frequency tracking based on the PSPM(phase-shifting pulse modulation) r regulation scherne is presented in or$\tau$ler to l11lmmlZe svvitching losses. The trially-produced breadboards using N Neuro Fuzzy controller are successfully demonstrated cUld cliscussed.

  • PDF

A Modified Switched-Diode Topology for Cascaded Multilevel Inverters

  • Karasani, Raghavendra Reddy;Borghate, Vijay B.;Meshram, Prafullachandra M.;Suryawanshi, H.M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1706-1715
    • /
    • 2016
  • In this paper, a single phase modified switched-diode topology for both symmetrical and asymmetrical cascaded multilevel inverters is presented. It consists of a Modified Switched-Diode Unit (MSDU) and a Twin Source Two Switch Unit (TSTSU) to produce distinct positive voltage levels according to the operating modes. An additional H-bridge synthesizes a voltage waveform, where the voltage levels of either polarity have less Total Harmonic Distortion (THD). Higher-level inverters can be built by cascading MSDUs. A comparative analysis is done with other topologies. The proposed topology results in reductions in the number of power switches, losses, installation area, voltage stress and converter cost. The Nearest Level Control (NLC) technique is employed to generate the gating signals for the power switches. To verify the performance of the proposed structure, simulation results are carried out by a PSIM under both steady state and dynamic conditions. Experimental results are presented to validate the simulation results.

High Precise Measurement of Grid-Connected Inverter using DFT (DFT를 이용한 계통연계 인버터 시스템의 고정밀 계측)

  • Lee, Sang-Hyeok;Kang, Feel-Soon;Lee, Sang-Hun;Cho, So-Eog;Lee, Tae-Won;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • A precise measurement of the grid voltage is one of the essential techniques, which is required to connect a renewable energy to the grid. In general, when a filter is used to eliminate unnecessary harmonics and noises, a signal is distorted by phase delay, amplitude attenuation, and other distortions. And the response characteristic of a controller is directly affected by bandwidth of cut-off frequency of the filter. To alleviate this problems, we propose an effective algorithm based on DFT(Discrete Fourier Transform) instead of approaching the filter application. The proposed algorithm ensures high precise measurement of the grid voltage because it can extract the fundamental and harmonics from the raw signal without any distortions. The high performance of the proposed algorithm is verified by PSIM simulation and experiments of Grid-Connected VSI.

Shunt Active Filter for Multi-Level Inverters Using DDSRF with State Delay Controller

  • Rajesh, C.R.;Umayal, S.P.
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.863-870
    • /
    • 2018
  • The traditional power control theories for the harmonic reduction methods in multilevel inverters are found to be unreliable under unbalanced load conditions. The unreliability in harmonic mitigation is caused by voltage fluctuations, non-linear loads, the use of power switches, etc. In general, the harmonics are reduced by filters. However, such devices are an expensive way to provide a smooth and fast response to secure power systems during dynamic conditions. Hence, the Decoupled Double Synchronous Reference Frame (DDSRF) theory combined with a State Delay Controller (SDC) is proposed to achieve a harmonic reduction in power systems. The DDSRF produces a sinusoidal harmonic that is the opposite of the load harmonic. Then, it injects this harmonic into power systems, which reduces the effect of harmonics. The SDC is used to reduce the delay between the compensation time for power injection and the generation of a reference signal. The proposed technique has been simulated using MATLAB and its reliability has been verified experimentally under unbalanced conditions.

Modeling of utility interactive photovoltaic system DC-DC converter (태양광 발전 시스템용 DC-DC 컨버터의 모델링)

  • Mun, S.P.;Park, Y.J.;Kim, Y.M.;Kang, W.J.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.215-217
    • /
    • 2002
  • In this paper, a new converter for utility interactive photovoltaic system is proposed, the conventional utility interactive photovoltaic system is composed of a PWM inverter and a DC converter. However, the increased switching loss and the high frequency switching noise become a problem. the control accuracy of the system is made to lower by the dead time of the switching devices. and it becomes a cause of the lower conversion efficiency. In order to resolve those problems, we applied a non- dissipative snubber circuit to a converter, which generates the single phase absolute value of sinusoidal current. the converter consists of two switching devices and one capacitor which constitute a non-dissipative snubber circuit. the proposed circuit is very useful to minimize and increase efficiency, when it is used to an utility interactive photovoltaic system. it is confirmed by simulation that the proposed converter for new photovoltaic system has stable operation and good output.

  • PDF

The Development Of the Electronic Ballast for HPS lamp using the RCD Snubber and Quasi-Square Wave (RCD 스너버 및 준구형파를 이용한 250[W] HPS lamp용 전자석 안정기 개발)

  • 강도형;박종연
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • In this paper, We have researched about the Electronic Ballast for 250W HPS(High Pressure Sodium) lamp. This Electronic Ballast is capable to operate the Ignition and Steady State Using the Class D LCC resonant tank, and minimizing the full-bridge inverter's Switching Stress by implementation Quasi-square ZC-ZVS Soft Switching Method. And also, We have reduced the heat of MOS-FETs and high frequency switching surge noise using the RCD damp snubber. Therefore, We are sure that the developed ballast has the properties of the stable & reliable Control and the function of minimizing the total noise of the system.

Acoustic-Resonance Reduction of Metal Halide Lamps Using Amplitude Modulation (진폭변조에 의한 메탈핼라이드 램프의 음향공명 감소)

  • 이치환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.43-49
    • /
    • 2000
  • In this paper, a new control method is presented to reduce acoustic resonance phenomena of metal halide lamps with electronic ballasts. A behavior of frequency controlled resonant inverter is analyzed and the transfer function is obtained. An integrator as a current controller for ballast is employed. By using both a disturbance of the lamp power and spread spectrum effects for reducing acoustic resonance, an amplitude modulation is done by using the current controller with 200[Hz] sinusoidal wave. Arc stabilities of MH 250[W] lamps are studied with changing the modulation index. Experiments with two MH 250[W] lamps, made by different manufacturers, showed the validity of the proposed method.

  • PDF

Bi-directional DC-DC Converter Design and Control for step-up/step-down (승강압용 양방향 DC-DC컨버터 설계 및 제어)

  • Won, Chung-Yuen;Jang, Su-Jin;Lee, Tae-Won;Lee, Byoung-Kuk;Kim, Soo-Suck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.49-56
    • /
    • 2006
  • The bi-directional converter interfaces the low voltage battery to the inverter do link of FC generation system. When power flows from the low voltage side(battery: 48[V]) to the high voltage side(dc link: 380[V]), the circuit works in discharge mode (boost) to power the high voltage side load; otherwise, it works in charge mode (buck) to charge the low voltage side battery. In this paper, the 1.5[kW] active clamp current-fed full bridge converter employing MOSFETs is operated to discharge the battery whereas a voltage-fed half bridge converter employing IGBTs is operated to charge the battery.

Development of the 3kW Class Low Cost Fuel Inverter System for Residential Power Generation - DC-DC Converter Design and Control for Fuel Cell System (3kW급 주택용에 사용되는 저가의 연료전지용 인버터 시스템 - 연료전지 시스템용 DC-DC 컨버터 설계 및 제어)

  • Lee, S.H.;Cho, M.C.;Hwang, G.D.;Mun, S.P.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1161-1162
    • /
    • 2006
  • 본 논문은 3[kW]급 연료전지와 연료전지의 저전압$[40{\sim}60[Vdc]$)을 승압(380vdc)하기 위한 풀-브리지 DC-DC 컨버터, 그리고 승압된 링크전압을 교류 상용전압(220[Vac], 60[Hz)으로 변환하기위한 단상 풀-브리지 인버터로 구성된 연료전지 발전용 전력변환시스템 중 연료전지 시스템용 DC-DC 컨버터를 제안하였다. 제안한 연료전지 시스템용 DC-DC 컨버터는 변압기 2차측에 배전류 정류회로를 삽입하여 기존의 고주파 변압기 보다 간단하면서 무게 및 부피를 줄였다. 그리고 위상 천이 PWM 제어로 출력 전압을 가변시켜 영전압 스위칭을 달성 함으로써 스위칭 손실을 줄였으며. 효율을 95%이상 달성 하였다.

  • PDF

Control Algorithm of H-Bridge Multi-level Inverter (H-브릿지 멀티레벨 인버터 제어알고리즘)

  • Kim, Bong-Suck;Ryu, Ho-Seon;Shin, Man-Su;Lee, Joo-Hyun;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.974-975
    • /
    • 2006
  • 본 논문에서는 대용량 전력 변환 장치이며 출력 전압 가변이 가능한 H-브릿지 멀티레벨 인버터의 제어 알고리즘을 제안한다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저압의 단상 인버터(셀 유닛)를 다수 직렬 접속하여 고압 3상 전압을 출력하는 Cascaded H-bridge 전압형 인버터이다. 다수의 독립 절연 직류부를 만들기 위해 입력 측에 다권선 변압기를 사용하여 입력 측 고조파 함유율을 축소시킬 수 있다. 인버터를 사용하는 제어방법 중 가장 오래되고 일반적인 방법으로 출력전압과 출력 주파수의 비를 일정하게 제어하여 전동기의 자속 크기를 일정하게 제어하고, 별도의 센서 없이도 운전이 가능한 V/F 제어모드는 저속 모드에서 제어 성능이 떨어지는 것을 실험을 통해 확인할 수 있었다. 정격용량 180kVA이고 출력 전압 480V인 H-브릿지 멀티 레벨 인버터 실험을 통해 벡터제어와 센서리스 벡터제어를 구현하여 저속 모드에서 제어 성능의 향상을 입증하였다.

  • PDF