• Title/Summary/Keyword: Inverter System

Search Result 2,788, Processing Time 0.037 seconds

A High Efficient Half-Bridge Inverter for Induction-Heating Applications with Non-Magnetic Load (비자성 부하 유도 가열용 Half-Bridge Inverter의 효율 향상에 대한 연구)

  • Jung, Jin-Woo;Lee, Byoung-Kuk;Suh, Bum-Seok;Hyun, Dong-Seok;Jung, Yun-Cheol;Park, Byoung-Wook;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.303-305
    • /
    • 1996
  • A strategy that can maximize the efficiency of the inverter system for the non-magnetic material is proposed. Frequency control and variable DC-Link voltage control are compared and analyzed by the experimental results. The experimental results show the variable DC-Link voltage control is superior to the frequency control with respect to improve the efficiency of the inverter system. MOSFETs and IGBTs are used as switching devices and IGBTs are considerable as better switching devices for improving the efficiency of the inverter system.

  • PDF

The Design of Fuse in High Efficient Inverter Control System using Ceramic Radiant Heat and Metal Film Laminated Plating (세라믹 방열과 박막 적층 도금을 이용한 고효율 인버터 제어 회로용 퓨즈 설계)

  • Kim, Eun-Min;Kim, Shin-Hyo;Cho, Dae-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1538-1544
    • /
    • 2014
  • In recent years, The electronic and energy industries demand low power consumption and high efficiency, so under their demands, the white goods industries which are represented for refrigerator and air conditioner system be implemented energy-saving power suppling structure with inverter control system. As inverter control system is different from step control type, when switching system is optimizing temperature control during short period, the inrush plus current can be flown in the circuit. In despite of these characteristics, there is no fuse which can be applied to this type until now. For this reason, we suggest the method of manufacturing protector in the high efficient inverter control system using the alumina-based ceramic radiated heat characteristics and metal films laminated plating. And through the evaluating electrical characteristics, we make a possible to utilize the method when designing overall fuses.

Ripple Voltage Compensation Instantaneous Follow Controller of Inverter by using Analog Integrator (아날로그 적분기를 이용한 맥동전압 보상형 순시추종 PWM 제어기를 적용한 인버터)

  • 라병훈;이현우;김광태
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • In this paper, it is suggested that instantaneous compensation PWM control for inverter without the smoothing capacitor Therefore, this inverter system has several advantages. It has small volume and low price to manufacture, decrease trouble rate of inverter, and has power factor correction effect because huge smoothing capacitor-less. And it has compact size control circuit to use analog integrator device. It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter.

Design of Test Equipment for LSM Section Switching Test (장계자형 LSM 섹션전환용 시험장치 설계)

  • Jo, Jeong-Min;Han, Young-Jae;Lee, Chang-Young;Cho, Ju-Hyun;Choi, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2383-2388
    • /
    • 2011
  • LSMs are installed under girders along the long track. In order to improve the efficiency of the LSM, long stator LSM should be divided into the specified length and the propulsion inverters should have the system topology to generate high voltage and current for LSMs. This paper presents a system topology with two-step inverter in order to generate high voltage in inverter. A LSM propulsion system is developed and implemented in Maltab/Simulink. A system model of the two-step Inverter is applied to developed model. This paper demonstrates through simulation, advantages of multi-step inverter. The conclusions can serve the design of LSM propulsion system.

  • PDF

Rotor Fault Detection System for Inverter Driven Induction Motors using Currents Signals and an Encoder

  • Kim, Nam-Hun
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.271-277
    • /
    • 2007
  • In this paper, an induction motor rotor fault diagnosis system using current signals, which are measured using the axis-transformation method is presented. Inverter-fed motor drives, unlike line-driven motor drives, have stator currents which are rich in harmonics and therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, an encoder and additional hardware. Therefore, the proposed axis-transformation method is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation, using the Park transformation, is compared with the results obtained from the FFT(Fast Fourier Transform).

A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit (공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구)

  • Han, Young-Seong;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.

Modeling and Simulation Technique of Two Quadrant Chopper and PWM Inverter-Fed IPMSM Drive System and Its Application to Hybrid Vehicles

  • Murata, Toshiaki;Kawatsu, Utaro;Tamura, Junji;Tsuchiya, Takeshi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2012
  • This paper presents a state space model of a two quadrant chopper and PWM inverter-fed Interior Permanent Magnet Synchronous Motor (IPMSM) drive system and its application to hybrid vehicles. The drive system has two different state equations for motoring and regenerating action. This paper presents a common state equation by using State Space Averaging method. Using this model of the IPMSM drive system, detailed simulation and controller design of the drive system, including PWM inverter switching, are given. The validity of this model and usefulness, according to a comparison among Maximum Torque/Ampere control, Maximum Torque/Flux control, and Maximum Efficiency optimization, are confirmed from simulation results.

A Scheme for Adoption of Regenerative Inverter in DC Transit System (직류급전시스템 회생용 인버터 개발 및 실계통 적용 방안)

  • Kim, Joo-Rak;Han, Moon-Seob;Chang, Sang-Hoon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1044-1045
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the adoption of developed inverter in commercial railway line and the test result procedure of developed inverter is presented.

  • PDF

A Disturbance Observer-Based Robust Controller Against Load Variations in a Single Phase DC/AC Inverter System (단상 DC/AC 인버터 시스템의 부하변동을 고려한 외란 관측기 기반 제어기)

  • Kim, Sung-Jong;Son, Young-Ik;Jeong, Yu-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.110-112
    • /
    • 2007
  • Output voltage waves of a DC/AC inverter system are likely to be distorted if variable loads e.g. motors or rectifiers exist in the output terminal. This paper designs a disturbance observer-based PI controller for a single-phase inverter system that is robust against load changes. In this paper, we regard the output voltage changes due to various loads as disturbances of the control system, Then we design a disturbance observer for estimation of the disturbances caused by the load current and any other error sources (such as parameter uncertainties and model mismatches etc.). In order to test the performance of the proposed control law, simulation studies are carried out for a single-phase inverter system using SimPowerSystems of Matlab Simulink. Compared to a simple PI control, the disturbance observer-based controller shows enhanced performance in transient responses for step load changes.

  • PDF

Transformer-less Inverter for Photovoltaic and small unit Windturbine System (태양광 및 소단위 풍력발전용 변압기 없는 인버터)

  • 박영산;김윤식;이성근;안병원;배철오
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.333-336
    • /
    • 2003
  • Designed transformer-less inverter for photovoltaic and small unit windturbine power system. This system consisted of boost chopper circuit of multiple-switching method and foil bridge PWM inverter. Transformer-less system was adapted to reduce cost and size. But in this system, earth-leakage current have to be considered. So, to solve this problem, we used PWM inverter switching method to reduce the earth-leakage current which flows in accordance with the variation of DC input common mode voltage.

  • PDF