• Title/Summary/Keyword: Inverter Application

Search Result 421, Processing Time 0.027 seconds

Dynamic analysis of Microturbine and FuelCell in MicroGrid using EMTP-RV (마이크로터빈과 연료전지의 EMTP-RV 모델링을 통한 마이크로그리드 내 동특성 분석)

  • Seo, Gyu-Seok;Ju, Jae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.42-48
    • /
    • 2010
  • The Microsource has to supply high quality Power that has high reliability and high energy efficiency to Load according to operating type of Microgrid. The energy sources of microsource type have various dynamic characteristic and transient response corresponding to classes and application skill. This paper shows dynamic characteristic of Microgrid according to Energy Source of microsource type. This research has been carried out by detailed modelling of Microturbine system and Fuelcell system. All models are realized by EMTP/RV and simulated change of operating type and load increase within Microgrid of DC constant voltage inverter model and Microturbine, Fuelcell based Microsource.

Moving Mesh Technique for Dynamic Characteristics Analysis of Permanent Magnet Linear Synchronous (영구 자석형 선형 동기전동기의 동특성 해석을 위한 이동 메쉬 기법)

  • Woo, Kyung-Il;Kwon, Byung-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.53-58
    • /
    • 2001
  • This paper describes a moving mesh technique for dynamic characteristics analysis of permanent magnet linear synchronous motor with the secondary aluminium sheet. The moving mesh technique applied to the linear induction motor can be used to analyze the linear synchronous motor with the rectangular permanent magnet. But in case of the permanent magnet with taper, the shape of the permanent magnet is presented. The time-stepped finite element method is used for the dynamic characteristics simulation of the permanent magnet linear synchronous motor, The results of application example(hysteresis current controlled inverter fed control) such as thrust, current and flux plots are shown.

  • PDF

Design and Application of CCFL Drive Inverter Transformer for LCD Backlight (LCD Backlight를 위한 CCFL 구동용 인버터 트랜스포머의 설계와 응용)

  • Cho, Sang-Ho;Han, Sang-Kyoo;Roh, Chung-Wook;Hong, Sung-Soo;SaKong, Sug-Chin;Kwon, Gi-Hyun;Lee, Hyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.190-192
    • /
    • 2007
  • LCD TV의 대형화에 따라 하나의 백라이트용 냉음극 방전램프(Cold Cathode Fluorescent Lamp ; CCFL)를 이용한 백라이트는 휘도의 한계가 있어 대형 디스플레이에서는 여러 개의 램프를 사용하여 필요한 휘도를 만들고 있다. 본 논문에서는 냉음극 방전램프 16개를 사용하는 42인치 LCD TV용 대형 백라이트 구동을 위한 인버터의 트랜스포머를 각기 다른 램프의 특성에 대해 동일한 관 전류 출력을 갖도록 설계하였다.

  • PDF

Electrical characteristics of Piezoelectric Transformer for PDA using PNW-PMN-PZT Ceramics (PNW-PNM-PZT 세라믹스 이용한 PDA용 압전 트랜스포머의 전기적특성)

  • Lee, Sang-Ho;Oh, Dong-On;Yoo, Ju-Hyun;Lyu, Sung-Lim;Park, Chang-Yub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.228-231
    • /
    • 2003
  • In this sturdy, piezoelectric transformer using PNW-PMN-PZT ceramics was fabricated with the size of $1{\times}16{\times}5mm^3$ for LCD backlight inverter application of PDA. And its electrical characteristics were investigated with load resistance and driving frequency. At the frequency of 212.6kHz, CCFL for PDA was driven stably, and input voltage of 8.83V and output voltage of 305V were shown.

  • PDF

Performance of Non Punch-Through Trench Gate Field-Stop IGBT for Power Control System and Automotive Application

  • Kang, Ey Goo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.50-55
    • /
    • 2016
  • In this paper, we have analyzed the electrical characteristics of 1200V trench gate field stop IGBT and have compared to NPT planar type IGBT and NPT planar field stop IGBT. As a result of analyzing, we obtained superior electrical characteristics of trench gate field stop IGBT than conventional IGBT. To begin with, the breakdown voltage characteristic was showed 1,460 V and on state voltage drop was showed 0.7 V. We obtained 3.5 V threshold voltage, too. To use these results, we have extracted optimal design and process parameter and designed trench gate field stop IGBT. The designed trench gate IGBT will use to inverter of renewable energy and automotive industry.

Average Current Mode Control Technique Having Fast Response (빠른 응답 특성을 가지는 Average Current Mode Control 설계 기법 연구)

  • Park, Hae-Chan;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.231-239
    • /
    • 2017
  • A novel current control technique with fast response and application in an unbalanced system is proposed in this paper. Contrary to the conventional PI and dead-beat current control techniques, the proposed method is adopted to the valley current mode control (VCMC) and average current mode control (ACMC) methods to overcome the phase delay caused by conventional methods. The advantages of the proposed system are simplicity of structure and ease of implementation. The VCMC and ACMC methods are established and applied to the buck converter, boost converter, three-phase PWM converter, and three-phase inverter. The control performances of the proposed systems are shown by computer simulations and verified by experimental results.

A Study on an Application of Level Shifted PWM for H-bridge Multilevel Inverter (H-브릿지 멀티레벨 인버터의 Level Shifted PWM 적용에 관한 연구)

  • Lee, Kwang-Hwan;Park, Young-Min
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.397-398
    • /
    • 2014
  • Phase Shifted PWM은 각각의 셀이 동일한 스위칭 주파수로 PWM을 수행하므로 전압지령의 크기와 관계없이 셀 간의 전력은 동일하나, 각 셀 출력 전압의 위상이 다르므로 무부하 운전이나 부하의 급변동 시 발생하는 회생이 특정 셀에 집중되고 전압지령과 실제 출력전압 사이의 위상 차이가 존재하는 단점을 가지고 있다. 반면 기존 Level Shifted PWM은 전압지령의 크기에 따라 각 셀 간의 스위칭 조건이 다르고 동일 전력 분배가 되지 않는 문제를 가지고 있어 이를 개선하는 Level Shifted PWM 방법에 대해서는 이미 연구가 진행된 상태이다. 본 논문에서는 제어기가 분산화된 H-브릿지 멀티레벨 인버터에 각 셀의 스위칭 조건을 동일하게 유지하는 Level Shifted PWM을 적용하기 위해서 전압지령을 보정하는 방법을 사용하였고 시뮬레이션과 시험을 통해 제어기가 분산화된 H-브릿지 멀티레벨 인버터에 적용 가능함을 증명하였다.

  • PDF

The Characteristic Analysis of VVVf Type High Frequency Inverter considering Dead Time (Dead Time을 고려한 VVVF형 고주파 인버어터의 특성해석)

  • Oh, Seung-Hoon;Bae, Sang-Jun;Min, Byoung-Jae;Lee, Dal-Hae;Choi, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.698-700
    • /
    • 1993
  • This paper describes characteristic analysis of VVVf type high-frequency considering dead time. Static power conversion are now used in a great variety of application including induction heating, high-frequency generation, DC/DC power converter, etc. In the circuit analysis, an offer circuit was compared with safety operating region and steady state characteristics considering dead time.

  • PDF

DC Voltage Balancing Control for Multilevel H-Bridge STATCOM (다단 인버터 STATCOM의 직류전압 평형 제어)

  • Kim, Kyoung-Jin;Song, Seong Ho;Jeong, Seung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.234-237
    • /
    • 2010
  • This paper proposes a balancing control of DC-link voltages of a H-bridge multilevel inverter for STATCOM application. Individual DC link voltage is controlled by simply adjusting the d-q voltage reference through a PI controller in each cell while the main controller carries out the reactive power control. The correctness and effectiveness of the method are validated by PSIM simulation with unbalanced load condition data taken from a typical arc furnace load, showing the adverse effects of load unbalance to DC link voltage significantly suppressed.

  • PDF

Analysis on the effect of harmonics filter applied to water treatment facilities (고조파 저감장치 현장적용 효과 분석)

  • Lee Eun Chun;Byun Il Hwan;Shin Gang Wook;Hong Sung Taek;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.273-275
    • /
    • 2004
  • Recently, many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit. and to show the effect of the harmonics filter.

  • PDF