• Title/Summary/Keyword: Inverter Application

검색결과 421건 처리시간 0.02초

The Output Characteristics of 3kW BIPV System (건물일체형 태양광발전시스템의 실증분석)

  • Kim, Ji-Hoon;Jie, Bian Wen;Lee, Kang-Yeon;Kim, Pyoung-Ho;Oh, Geum-Gon;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.386-389
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. In case of PV(photovoltaic system) there are many generation differences according to the exterior environmental facts(solar cell array, design and installation condition of interactive inverter system). In this paper, we compared constitute factors of 3kW BIPV(solar cell module, inverter), operating characteristic and total system characteristic(utilization, generation efficiency, loss fact) and found out long time operating data using a watch instrumentations. By use of long time operating result, compare a totally operating characteristics, and we proposed a next building application of BIPV. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. The objective of this paper, is to provide a efficient BIPV design method through the considerations for the integration of PV system.

  • PDF

A Novel Regenerative Snubber suitable to Multi-Level Inverters with Series-Connected GTOs (직렬 연결된 GTO로 구성된 멀티레벨 인버터에 적합한 새로운 회생 스너버에 관한 연구)

  • Chae, G.;Cho, Guk-C.;Jung, Gu-H.;Ryoo, Tae-H.;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.585-587
    • /
    • 1996
  • A simple regenerative snubber structure is proposed, which is applicable to multi-level inverter with series-connected GTOs for high power applications. The novel snubber structure can solve large energy loss problems and guarantee safe operation of power converter can be achieved. The proposed new snubber has the potential of high performance and high reliability and is particularly suitable to high power and multi-level application with series connected power devices. The snubber voltage and current waveforms are analized and shown the simulation and experimental results for a GTO 3-level inverter circuit with inductive load.

  • PDF

Harmonic Analysis and Output Filter Design of NPC Multi-Level Inverters (NPC 멀티레벨 인버터의 고조파 분석 및 출력 필터 설계)

  • Kim, Yoon-Ho;Bang, Sang-Seok;Kim, Kwang-Seob;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.135-141
    • /
    • 2006
  • In this paper, LC output filters are designed to reduce output harmonics and harmonic analysis are peformed. Generally, multilevel inverters are used in high power application and operates with low switching frequency, which, in turn, generates large output harmonics. Output filters we used to reduce output harmonics. The design approach to reduce output harmonics of the 31eve1 multilevel inverter is discussed and DSP(TMS320C31) is used for the digital control of the system. The design example is given. The designed system is verified by simulation and experiment.

Improved Decoupled Control and Islanding Detection of Inverter-Based Distribution in Multibus Microgrid Systems

  • Pinto, Smitha Joyce;Panda, Gayadhar
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1526-1540
    • /
    • 2016
  • This work mainly discusses an accurate and fast islanding detection based on fractional wavelet packet transform (FRWPT)for multibus microgrid systems. The proposed protection scheme uses combined desirable features retrieved from discrete fractional Fourier transform (FRFT) and wavelet packet transform (WPT) techniques, which provides precise time-frequency information on minute perturbation signals introduced in the system. Moreover, this study focuses on the design of decoupling control with a distributed controller based on state feedback for the efficient operation of microgrid systems that are transitioning from the grid-connected mode to the islanded mode. An IEEE 9-bus test system with inverter based distributed generation (DG) units is considered for islanding assessment and smooth operation. Finally, tracking errors are greatly reduced with stability improvement based on the proposed controller. FRWPT based islanding detection is demonstrated via a time domain simulation of the system. Simulated results show an improvement in system stability with the application of the proposed controller and accurate islanding detection based on the FRWPT technique in comparison with the results obtained by applying the wavelet transform (WT) and WPT.

Identification of Open-Switch and Short-Switch Failure of Multilevel Inverters through DWT and ANN Approach using LabVIEW

  • Parimalasundar, E.;Vanitha, N. Suthanthira
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2277-2287
    • /
    • 2015
  • In recent times, multilevel inverters are given high priority in many large industrial drive applications. However, the reliability of multilevel inverters are mainly affected by the failure of power electronic switches. In this paper, open-switch and short-switch failure of multilevel inverters and its identification using a high performance diagnostic system is discussed. Experimental and simulation studies were carried out on five level cascaded H-Bridge multilevel inverter and its output voltage waveforms were analyzed at different switch fault cases and at different modulation index values. Salient frequency domain features of the output voltage signal were extracted using the discrete wavelet transform multi resolution signal decomposition technique. Real time application of the proposed fault diagnostic system was implemented through the LabVIEW software. Artificial neural network was trained offline using the Matlab software and the resultant network parameters were transferred to LabVIEW real time system. In the proposed system, it is possible to precisely identify the individual faulty switch (may be due to open-switch (or) short-switch failure) of multilevel inverters.

The Study on Inverter DC Resistance Spot Welding Character & Mechanical Property of DP60 Steels (DP60강의 인버터 DC 저항 용접의 용접 특성 및 기계적 성질에 관한 연구)

  • Kim, In-Ju
    • Proceedings of the KAIS Fall Conference
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 2부
    • /
    • pp.604-606
    • /
    • 2011
  • Purpose This study analyzes resistance spot weldability of DP60 steels. Methodology To compare the resistance spot weldability of DP60 steels, tensile strength test and macro-section test were conducted for the resistance spot welds. Acceptable welding conditions were determined as a function of the resistance spot welding process parameters such as electrode force, welding time, and welding current. The lower limit of the welding lobe was the minimum shear tension strength for 590MPa-grade steel while the upper limit was determined whether or not expulsion was detected. Findings Welding force is 200kgf more appropriate in terms of 300kgf the larger the width of the welding zone. Acceptable welding current condition and welding lobe were changed depending on welding force. Research limitations This study is forced on inverter DC resistance spot weldability of 590Mpa-grade steels for automotive application. Practical implications This study confirms the weldability of DP60 steel by comparing resistance spot weldability depending on welding force. Originality This study analysed resistance spot weldability depending on welding force. wedability of DP60 steel were determined by welding lobes.

  • PDF

Development of Algorithm for Maximum Power Point Tracking of PV system (PV 시스템의 최대출력점 추정을 위한 알고리즘 개발)

  • Park, Ki-Tae;Ko, Jae-Sub;Choi, Jung-Sik;Park, Byung-Sang;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.316-321
    • /
    • 2007
  • This paper is proposed a novel method to approximate the maximum power for a photovoltaic inverter system and tracking method. It is designed for power systems application and utilities. The proposed Maximum Power Point Tracking(MPPT) control has the advantage to provide a new simple way to approximate the optimal or rated voltage, the optimal or rated current and maximum power rating produced by a solar panel and the photovoltaic inverter. And this straightforward method will be named linear reoriented coordinates method(LRCM) with the advantage that Pmax and $V_{op}$ can be approximated using the satre variable as the dynamic model without using complicate approximations or Taylor series. Furthermore tracking method is improved over 50% photovoltaic efficiency. This paper is proposed MPPT using LRMC and tracking method using weather condition of domestic moderate program technique. This paper is proposed the experimental results to verify the effectiveness of the new methods.

  • PDF

A Novel Modulation Method for Three-Level Inverter Neutral Point Potential Oscillation Elimination

  • Yao, Yuan;Kang, Longyun;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.445-455
    • /
    • 2018
  • A novel algorithm is proposed to regulate the neutral point potential in neutral point clamped three-level inverters. Oscillations of the neutral point potential and an unbalanced dc-link voltage cause distortions of the output voltage. Large capacitors, which make the application costly and bulky, are needed to eliminate oscillations. Thus, the algorithm proposed in this paper utilizes the finite-control-set model predictive control and the multistage medium vector to solve these issues. The proposed strategy consists of a two-step prediction and a cost function to evaluate the selected multistage medium vector. Unlike the virtual vector method, the multistage medium vector is a mixture of the virtual vector and the original vector. In addition, its amplitude is variable. The neutral point current generated by it can be used to adjust the neutral point potential. When compared with the virtual vector method, the multistage medium vector contributes to decreasing the regulation time when the modulation index is high. The vectors are rearranged to cope with the variable switching frequency of the model predictive control. Simulation and experimental results verify the validity of the proposed strategy.

Current-Source PWM Inverter Equipped with DSP for Photovoltaic System (DSP를 이용한 태양광 발전 시스템용 전류형 PWM 인버터)

  • 박성준;허권행;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제7권5호
    • /
    • pp.437-442
    • /
    • 2002
  • This paper presents a current-source-inverter based on a buck-boost configuration md its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150[W] prototype equipped with digital signal processor TMS320F241.

Theoretical Analysis and Control of DC Neutral-point Voltage Balance of Three-level Inverters in Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.344-356
    • /
    • 2012
  • In recent years, multilevel technology has become an effective and practical solution in the field of moderate and high voltage applications. This paper discusses an APF with a three-level NPC inverter. Obviously, the application of such converter to APFs is hindered by the problem of the voltage unbalance of DC capacitors, which leads to system instability. This paper comprehensively analyzes the theoretical limitations of the neutral-point voltage balancing problem for tracking different harmonic currents utilizing current switching functions from the space vector PWM (SVPWM) point of view. The fluctuation of the neutral point caused by the load currents of certain order harmonic frequency is reported and quantified. Furthermore, this paper presents a close-loop digital control algorithm of the DC voltage for this APF. A PI controller regulates the DC voltage in the outer-loop controller. In the current-loop controller, this paper proposes a simple neutral-point voltage control method. The neutral-point voltage imbalance is restrained by selecting small vectors that will move the neutral-point voltage in the direction opposite the direction of the unbalance. The experiment results illustrate that the performance of the proposed approach is satisfactory.